DOWNLOAD Sony DVP-K85P / DVP-K86P Service Manual ↓ Size: 5.69 MB | Pages: 84 in PDF or view online for FREE

Model
DVP-K85P DVP-K86P
Pages
84
Size
5.69 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-k85p-dvp-k86p.pdf
Date

Sony DVP-K85P / DVP-K86P Service Manual ▷ View online

6-1
DVP-K86P
SECTION 6
TEST MODE
6-1.
EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
[POWER]
to enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
5. Video Level Adjustment
Model Name : xxx xxx xxx
IF-con
: Ver. xxx
Syscon
: Ver. xxx
(2)
Select “2. Drive Manual Operation” by pressing the 2 key
on the remote commander. The screen will appear as below.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
0. Return to top Menu
(3)
Select “3. Manual Adjustment” by pressing the 3 key on
the remote commander. The screen will appear as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(4)
Select Iop by pressing 6 key on the remote commander.
(5)
Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(6)
Convert data from hexadecimal to decimal.
(7)
Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
(8)
Press [RETURN] to return back to previous menu.
(9)
Press - to return to Top Menu and power OFF the DVD
Player.
6-2.
EMERGENCY HISTORY CHECK
Information of Emergency History.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
[POWER]
to enter Remocon Diagnosis Mode.
(2)
Select “3. Emergency History”.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
-
 Return to Top Menu
(3)
Laser Hours
DVD Laser ON time. (Total ON time)
CD Laser ON time. (Total ON time)
(4)
Emergency History
The history information from last “1” to “10” can be scrolled
with [NEXT] key or [PREV] key.
(5)
Error code
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
6-1
DVP-K86P
SECTION 6
TEST MODE
6-1.
EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard
procedures must be followed.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
[POWER]
to enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
5. Video Level Adjustment
Model Name : xxx xxx xxx
IF-con
: Ver. xxx
Syscon
: Ver. xxx
(2)
Select “2. Drive Manual Operation” by pressing the 2 key
on the remote commander. The screen will appear as below.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
0. Return to top Menu
(3)
Select “3. Manual Adjustment” by pressing the 3 key on
the remote commander. The screen will appear as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(4)
Select Iop by pressing 6 key on the remote commander.
(5)
Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(6)
Convert data from hexadecimal to decimal.
(7)
Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
(8)
Press [RETURN] to return back to previous menu.
(9)
Press - to return to Top Menu and power OFF the DVD
Player.
6-2.
EMERGENCY HISTORY CHECK
Information of Emergency History.
(1)
In standby mode, press 
[TOP MENU]
[CLEAR]
[POWER]
to enter Remocon Diagnosis Mode.
(2)
Select “3. Emergency History”.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
-
 Return to Top Menu
(3)
Laser Hours
DVD Laser ON time. (Total ON time)
CD Laser ON time. (Total ON time)
(4)
Emergency History
The history information from last “1” to “10” can be scrolled
with [NEXT] key or [PREV] key.
(5)
Error code
Example of Error code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
6-3
DVP-K86P
(4)
The Emergency history display screen will be restored soon.
Emg. History Check
Laser Hours
CD
999h
59min
DVD
999h
59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
-
 Return to Top Menu
(12) Press - key, return to TOP MENU.
6-4. VERSION INFORMATION
Information of firmware version.
(1)
In standby mode, press [TOP MENU], [CLEAR], [POWER] to
enter Remocon Diagnosis Mode.
(2)
Select “4. Version Information”.
Version information
Firm (Main)
: Ver. xxxxx
Firm (Sub)
: xxxxx
RISC
: xxxxx
8032
:  xxxxx
Audio DSP
: xxxxx
Servo DSP
: xxxxx
-
 Return to Top Menu
(3)
Press - key, return to TOP MENU.
6-5. IF  CON SELF DIAGNOSTIC FUNCTION
1.
IF-149 BOARD (IF CON) TEXT MODE
The IF-149 board (IF CON) test mode is the IF CON
self-diagnosis mode. The IF CON can diagnose the functions of the
IF-149 board that the IF CON controls. Normally, the IF CON
makes a serial communication with the SYSTEM CONTROL and
operates following the commands from the SYSTEM CONTROL,
but in the Test mode, the IF CON operates independently from the
SYSTEM CONTROL.
In the test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Fluorescent display tube lighting check
- Grid check
- Anode check
5. LED control function
In the test mode, the main unit operates same as usual, except
voltage monitoring, communication, display of fluorescent display
tube, and LED control.
1. The routine that monitors +3.3V (PCONT) of MV-51 board is
not provided.
2. The monitoring timer for serial communication with the
SYSTEM CONTROL is not provided. The main unit is not
placed in the Standby mode, even if the communication with
SYSTEM CONTROL is normal.
3. Display of fluorescent display tube.
(Normally, display is mode following the commands from
SYSTEM CONTROL).
4. LED control.
(Normally, control is mode made following the commands from
SYSTEM CONTROL).
2.
OPERATION OF SELF CHECK MODE
The Self Check mode is the function to conduct the basic test to the
FL display and DVD panel section.
2-1.
Self Check Mode Transition Processing
At the AC Power ON after reset of IF CON is released, while
pressing with the MV-51 board are not connected to the
IF-149 board, or while pressing the  
x
  key on the main unit with
the IF CON in STANDBY mode, enter [RETURN] 
t [DISPLAY]
(or [SETUP]) on the remote commander, and the main unit transits
to the Self Check Mode.
6-4
DVP-K86P
2-2.
Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON or by key input, the test display of the following steps (1) to (4) is repeated.
(1)
FLD and LED all ON (for 10 seconds)
(2)
MODEL display (for 1 second)
(3)
Version display (for 1 second)
(4)
ROM creation date display (for 1 second)
Page of 84
Display