DOWNLOAD Sony DVP-K360 Service Manual ↓ Size: 19.12 MB | Pages: 107 in PDF or view online for FREE

Model
DVP-K360
Pages
107
Size
19.12 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-k360.pdf
Date

Sony DVP-K360 Service Manual ▷ View online

5-2 E
Pin No.
Pin name
I/O
Function
71
XWRH
O
High byte write enable signal output (16 bit and 8 bit)
72
XWRL
-
Not used
73
NMIX
-
Not used (fixed at “H”)
74
HSTX
-
Not used (fixed at “H”)
75
VSS
-
Ground
76
XFRRST
I
Reset signal input from IF CON
77
CPUCK
O
CPU clock signal output
78
OCSW2
-
Not used
79
XDACS
O
Chip select signal output to DAC (2ch, 6ch)
80
VESCS/X39CS
O
Chip select signal output to DSP
81
48/44.1K
O
PLL FS control signal output
82
WIDE
O
WIDE select signal output
83
MAMUTE
O
Audio mute signal output
84
XLDON
O
LD control signal output
85-92
HD0-HD7
I/O
Data bus D0-D7 (16 bit only)
93-100
HD8-HD15
I/O
Data bus D8-D15 (16 bit) , D0-D7 (8 bit)
101
VSS
-
Ground
102-109
HA0-HA7
O
Address bus A00-A07
110
VCC
-
Power supply
111-118
HA8-HA15
O
Address bus A08-A15
119
VSS
-
Ground
120
HA16
O
Address bus A16
6-1
6-3.
SYSCON  DIAGNOSIS
The same contents as board detail check by serial interface can be
checked from the remote commander.
On the Test Mode Menu screen, press 
[0]
 key on the remote com-
mander, and the following check menu will be displayed.
### Syscon Diagnosis ###
Check Menu
0. Quit
1. All
2. Version
3. Peripheral
4. Servo
5. Supply
6. AV Decoder
7. Video
8. Audio
_
0. Quit
Quit the Syscon Diagnosis and return to the Test Mode Menu.
1. All
All items continuous check
This menu checks all diagnostic items continuously. Normally, all
items are checked successively one after another automatically
unless an error is found, but at a certain item that requires judg-
ment through a visual check to the result, the following screen is
displayed for the key entry.
### Syscon Diagnosis ###
Diag All Check
No. 2 Version
 2-3. ROM Check Sum
Check Sum = xxxx
Press NEXT Key to Continue
Press PREV Key to Repeat
_
For the ROM Check, the check sum calculated by the Syscon is
output, and therefore you must compare it with the specified value
for confirmation.
Following the message, press 
[NEXT]
 key to go to the next item,
or 
[PREV]
 key to repeat the same check again. To quit the diagno-
sis and return to the Check Menu screen, press 
[STOP]
 or
[ENTER]
 key. If an error occurred, the diagnosis is suspended
and the error code is displayed as shown below.
### Syscon Diagnosis ###
 3-3. EEPROM Check
Error 03: EEPROM Write/Reed N
Address
: 00000001
Write Data : 2492
Read Data
: 2490
Press NEXT Key to Continue
Press PREV Key to Repeat
_
Press 
[STOP]
 key to quit the diagnosis, or 
[PREV]
 key to repeat
the same item where an error occurred, or 
[NEXT]
 key to continue
the check from the item next to faulty item.
6-1.
GENERAL  DESCRIPTION
The Test Mode allows you to make diagnosis and adjustment eas-
ily using the remote commander and monitor TV. The instructions,
diagnostic results, etc. are given on the on-screen display (OSD).
Note: Since the remote commander belongs to this model has no
number buttons, use other DVD remote commander with
number buttons on it.
6-2.
STARTING  TEST  MODE
Press the 
[TITLE]
[CLEAR]
[POWER]
 keys on the remote com-
mander in this order with the power of main unit in OFF status,
and the Test Mode starts, then “DIAG START” will be displayed
on the fluorescent display tube and the menu shown below will be
displayed on the TV screen. At the bottom of menu screen, the
model name and revision number are displayed. Last Off at the
lower right of screen indicates the information code concerning
the last power off.
To execute each function, select the desired menu and press its
number on the remote commander.
To exit from the Test Mode, press the 
[POWER]
 key.
Test Mode Menu
0. Syscon Diagnosis
1. Drive Auto Adjustment
2. Drive Manual Operation
3. Mecha Aging
4. Emergency History
5. Version Information
6. Video Level Adjustment
Exit: POWER Key
_
Model  : DPX-14xxxx
Revision : 1.xxxx
Last Off: xx
Power Off Information Code List
00 :
Primary Power Off
01 :
Power Off Request from SYSTEM CONTROL
02 :
Power Off by Emergency Power Off Command from SYS-
TEM CONTROL
 (if information is sent from SYSTEM CONTROL)
03 :
IF CON Judged that SYSTEM CONTROL is Faulty
04 :
Power Off from Diagnosis Mode of IF CON
05 :
Forced Power Off by the User
06 :
Power Off by Power Supply Voltage Monitor
SECTION  6
TEST  MODE
DVP-K360
6-2
Submenu
Selecting 2 and subsequent items calls the submenu screen of each
item.
For example, if “5. Supply” is selected, the following submenu
will be displayed.
### Syscon Diagnosis ###
Check Menu
No. 5 Supply
0. Quit
1. All
2. ARP Register Check
3. ARP to RAM Data Bus
4. ARP to RAM Address Bus
5. ARP RAM Check
_
0. Quit
Quit the submenu and return to the main menu.
1. All
All submenu items continuous check.
This menu checks 2 and subsequent items successively. At the item
where visual check is required for judgment or an error occurred,
the checking is suspended and the message is output for key entry.
Normally, all items are checked successively one after another au-
tomatically unless an error is found.
Selecting 2 and subsequent items executes respective menus and
outputs the results.
For the contents of each submenu, see “General Description of
Checking Method” and “Check Items List”.
General Description of Checking Method
2. Version
(2-2) Revision
ROM revision number is displayed.
Error: Not detected.
The revision number defined in the source file of ROM
(IC107) is displayed with four digits.
(2-3) ROM Check Sum
Check sum is calculated.
Error: Not detected.
8-bit data are added up to the ROM (IC107) address
0x000F0000 to 0x002EFFFF, and the result is displayed
with 4-digit hexadecimal number. Error is not detected.
Compare the result with the specified value.
(2-5) Region
Region code is displayed.
Error: Not detected.
The region code determined from the model code is dis-
played.
(2-6) AD 3 PORT Check
AD 3 PORT status is displayed.
Error: Not detected.
Which status, High (Pull Up), NC (Non Connect), or Low
(Pull Down), the AD 3 PORT is placed in now is checked.
3. Peripheral
(3-2) Gate Array Check
Data write 
 read, and accord check
Error 02: Gate array write/read discord
Data of 0x00 to 0xFF is written sequentially to the address
0xF and then read for checking.
(3-3) EEPROM Check
Data write 
 read, and accord check
Error 03: EEPROM write/read discord
0x9249, 0x2942 and 0x4294 are written to the address 0x00
to 0xFF of the EEPROM and then read for checking. Be-
fore writing, the data are saved, then after checking, they
are written to restore the contents of EEPROM.
4. Servo
(4-2) Servo DSP Check
Data write 
 read, and accord check
Error 12: Read data discord
0x9249, 0x2942 and 0x4294 are written to the RAM ad-
dress 0x602 of the Servo DSP and then read for checking.
Also, OPT type “1 LASER” or “2 LASER” is displayed.
(4-3) DSP Driver Test
Test signal data 
 DSP Driver
Error: Not detected.
Caution: Do not perform this checking with the mechanical deck
connected.
The maximum voltage is applied to the Servo Driver IC
(IC401). If the mechanical deck is connected, it will be
destroyed immediately. Following the output message,
disconnect the mechanical deck, then enter the specified
4- or 5-digit value from the commander, and press the
[ENTER]
 key. The test is conducted only if the entered
value accords. To exit the test, check the output level,
then press 
[NEXT]
 key.
This check is not conducted, but skipped in “All” menu
item.
Supplement: How to disconnect mechanical deck
Disconnect flexible flat cables connected to the
CN201 and CN202 of MB-98 board. Also, discon-
nect flat cable from the CN402.
(2-4) Model Type
Model code is displayed.
Error: Not detected.
The model code read from the EEPROM is displayed with
2-digit hexadecimal number.
Model Type
DVP-K360 (Chinese)
3
6
DVP-K360 (EXCEPT Chinese)
3
7
6-3
5. Supply
(5-2) ARP Register Check
Data write 
 read, and accord check
Error 08: ARP register write, and read data discord
Data 0x00 to 0xFF is written sequentially to the ARP TMAX
register (address 0xC6) and then read for checking.
(5-3) ARP to RAM Data Bus
Data write 
 read, and accord check
Error 09: ARP 
←→
 RAM data bus error
Data 0x0001 to 0x8000 where one bit each is set to 1 are
written to the address 0 of RAM (IC303) connected to the
ARP (IC302) through the bus, then they are read and
checked. In case of discord, written bit pattern and read
data are displayed. If data where multiple bits are 1 are
read, the bits concerned may touch each other. Further, if
data where certain bit is always 1 or 0 regardless of written
data, the line could be disconnected or shorted.
(5-4) ARP to RAM Address Bus
Data write 
 other address read discord check
Error 10: ARP 
←→
 RAM address bus error
Caution: Address and data display in case of an error is
different from the display of other diagnosis (de-
scribed later).
Before starting the test, all addresses of RAM (IC303) are
cleared to 0x0000.
First, 0xA55A is written to the address 0x00000, and the
address data are read and checked from addresses 0x00001
to 0x80000 while shifting 1 bit each. Next, the data at that
address is cleared, and it is written to the address 0x00001,
and read and checked in the same manner. This check is
repeated up to the address 0x80000 while shifting the ad-
dress data by 1 bit each.
If data other than 0 is read at the addresses except written
address, an error is given because all addresses were al-
ready cleared to 0. In this check, the error display pattern is
different from that of other diagnosis; read data, written
address, and read address are displayed in this order. How-
ever, the message uses same template, and accordingly ex-
change Address and Data when reading. The following dis-
play, for example,
### Syscon Diagnosis ###
 5-4. ARP to RAM Address Bus
Error 10: ARP - RAM Address B
Address
: 0000A55A
Write Data : 00000000
Read Data
: 00080000
Press NEXT Key to Continue
Press PREV Key to Repeat
_
shows the data 0xA55A was read from address 0x00080000
though it was written to the address 0x00000000. This im-
plies that these addresses are in the form of shadow. Also,
if the read data is not 0xA55A, another error will be present.
(5-5) ARP RAM Check
Data write 
 read, and accord check
Error 11: ARP RAM read data discord
The program code data stored in ROM are copied to all
areas of RAM (IC303) connected to the ARP (IC302)
through the bus, then they are read and checked if they ac-
cord. If the detail check was selected initially, the data are
written to all areas and read, then the same test is conducted
once again with the data where all bits are inverted between
1 and 0. If discord is detected, faulty address, written data,
and read data are displayed following the error code 11,
and the test is suspended.
6. AV Decoder
(6-2) 1930 RAM
Data write 
 read, and accord check
Error 13: AVD RAM read data discord
The program code data stored in ROM (IC107) are copied
to all areas of RAM (IC504, IC505) connected to the AVD
(IC503) through the bus, then they are read and checked if
they accord. Further, the same test is conducted once again
with the data where all bits are inverted between 1 and 0. If
discord is detected, faulty address, written data, and read
data are displayed following the error code 13, and the test
is suspended.
During the test, OSD display becomes blank as the OSD
area is also checked.
(6-3) 1930 SP
ROM 
 AVD RAM 
 Video OUT
Error: Not detected.
The data including sub picture streams in ROM (IC107)
are transferred to the RAM (IC504, IC505) in AVD (IC503),
and output as video signals from the AVD (IC503).
Though OSD display becomes blank, the output of video
signals continues until the key is pressed.
 They are output from all video terminals (Composite, Y/
C, Component) except EURO AV terminal.
7. Video
(7-2) Color Bar
AVD color bar command write 
 Video OUT
Error: Not detected.
The command is transferred to the AVD, and the color bar
signals are output from video terminals.
They are output from all video terminals (Composite, Y/C,
Component) except EURO AV terminal.
8. Audio
(8-2) ARP 
 1930
Error 14 : ARP 
 1930 video NG
15 : ARP 
 1930 audio NG
(8-3) Test Tone
A pink noise signal is output from the AVD (IC503) through
optical coaxial digital terminal and analog audio terminal.
Error: Not detected.
After turning on all outputs, each time the 
[NEXT]
 key is
pressed, the output channel is switched for individual chan-
nel checking.
Left + Right 
 Left 
 Right are checked in this order.
Page of 107
Display

Click on the first or last page to see other DVP-K360 service manuals if exist.