DOWNLOAD Sony DVP-F5 / DVP-FX1 Service Manual ↓ Size: 23.56 MB | Pages: 122 in PDF or view online for FREE

Model
DVP-F5 DVP-FX1
Pages
122
Size
23.56 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-f5-dvp-fx1.pdf
Date

Sony DVP-F5 / DVP-FX1 Service Manual ▷ View online

6-15
22. Auto LCD test display
Command
: 22
Operation
: The following operation is repeated.
LCD all segments turn on (5 seconds) All
segments turn on (5 seconds) 
→ Model name
display (2 seconds) 
→ ROM version display (2
seconds) 
→ ROM creation date display (2
seconds).
LCD display : As described above.
23. Initialization of the outputs that are set by the test
mode
Command
: 23
Operation
: The forced output that is specified by the test
mode item No. 6, No. 7, No. 10 to No. 7 and No.
30 to No. 32 are initialized.
LCD display : “23 
− ini”
* The TFT PANEL is set to the default state from
the NTSC/PAL setting.
* POWER_SAVE TFT inverter high output
* Forced ON output to TFT LCD INVPCON
* Forced ON output to TFT LCD power supply
TFTPCON
* LCD backlight check forced ON output
* CHGCNT forced OFF output, LBCHG forced
ON output
24. SW 3.3 V check
Command
: 24
Operation
: The 3.3 V input voltage is displayed on LCD.
* Valid range during POWER ON
2.02 V (272h)        PON_CHK        2.42 V
(2FDh)
* Valid range during STAND-BY
PON_CHK        0.1 V (01Fh)
LCD display : “24 
− XXX”.  XXX is the input voltage.
* Reference value : This value is around 2C6.
25. DC_OUT check
Command
: 25
Operation
: The DC_OUT voltage is displayed on LCD.
* Valid voltage when the DC OUT JACK is
connected.
1.28 V (18Dh)        DC OUT MNT
LCD display : “25 
− XXX”.  XXX is the input voltage.
* Reference value : This value is around 1A8 to
198.
26. BATT-MNT check
Command
: 26
Operation
: The BATT voltage is displayed on LCD.
* Valid voltage when operated on battery.
1.43 V (1BDh)        BATTMNT < 2.03 V (276h)
LCD display : “26 
− XXX”.  XXX is the input voltage.
* Reference value : This value is around 275 to
1BD.
27. DC_IN check
Command
: 27
Operation
: The DC_IN voltage is displayed on LCD.
* Valid voltage when operated on DC.
1.96 V (261h)        VCCMNT    <   2.65 V
(335h)
LCD display : “27 
− XXX”.  XXX is the input voltage.
* Reference value : This value is around 261 to
334.
<
=
<
=
<
=
<
=
<
=
<
=
28. TFT LCD EVR adjustment (NTSC setting)
Command
: 28
Operation
: Even when the LINE IN/OUT is switched by
the VIDEO switch for the TFT LCD monitor
EVR adjustment, the DVDPCON is maintained
in the ON state and the V_IOCNT output is
switched so that the LINE OUT picture or the
LINE IN picture is output to the TFT LCD.
When the machine enters this mode, the state
that is specified by the test mode is initialized.
* XPAL and EVR setting
During LINE IN mode
XPAL : NTSC setting
EVR : NTSC setting
During LINE OUT mode
XPAL : NTSC setting
EVR : NTSC setting
LCD display : “28-tFt” + NTSC segment display
29. TFT LCD EVR adjustment (PAL setting)
Command
: 29
Operation
: Even when the LINE IN/OUT is switched by
the VIDEO switch for the TFT LCD monitor
EVR adjustment, the DVDPCON is maintained
in the ON state and the V_IOCNT output is
switched so that the LINE OUT picture or the
LINE IN picture is output to the TFT LCD.
When the machine enters this mode, the state
that is specified by the test mode is initialized.
* XPAL and EVR setting
During LINE IN mode
XPAL : PAL setting
EVR : PAL setting
During LINE OUT mode (The XPAL is set to
the NTSC setting in order to display the
SYScon diagnosis display on the TFT LCD.)
XPAL : NTSC setting
EVR : PAL setting
LCD display : “29-tFt” + NTSC segment display
30. Forced CHGCNT ON & LBCHG OFF
Command
: 30
Operation
: The CHGCNT is forced to ON and the LBCHG
is forced to OFF.  (The charging processing is
interrupted.)
When charging is in progress in the STAND
BY mode, the charging processing is interrupted.
When charging is in progress in the POWER ON
mode, the machine enters the forced STAND-
BY mode.
When 10 minutes have elapsed after the forced
charge is set to ON, the forced charging is
cancelled.
When charging is started by any commands other
than this command, the machine follows their
outputs after charging is started once.
LCD display : “30 
− on”
6-16
31. CHGCNT OFF & LBCHG ON
Command
: 31
Operation
: The CHGCNT is forced to OFF and the LBCHG
is forced to ON.
When charging is in progress in the STAND-
BY mode, the charging processing is interrupted.
When charging is in progress in the POWER ON
mode, the machine enters the forced STAND-
BY mode.
When charging is started by any commands other
than this command, the machine follows their
outputs after charging is started once.
LCD display : “31 
− OFF”
32. Forced CHGCNT ON & LBCHG ON (State of forced
charging the low voltage battery)
Command
: 32
Operation
: The CHGCNT is forced to ON and the LBCHG
is forced to ON.  (The charging processing is
interrupted.)
When charging is in progress in the STAND-
BY mode, the charging processing is interrupted.
When charging is in progress in the POWER ON
mode, the machine enters the forced STAND-
BY mode.
When 10 minutes have elapsed after the forced
charge is set to ON, the forced charging is
cancelled.
When charging is started by any commands other
than this command, the machine follows their
outputs after charging is started once.
LCD display : “32 
− on”
33. (intentionally left blank)
34. Forced STAND-BY state setting
Command
: 34
Operation
: When charging is in progress in the POWER ON
mode, the machine enters the forced STAND-
BY mode.
The charging processing is interrupted and the
charging is re-started.
LCD display : “34 
− St”
35. (intentionally left blank)
36. VCCMNT voltage during charging display
Command
: 36
Operation
: The VCCMNT voltage that is inputted by the
charging sequence is displayed.
* Valid voltage of VCCMNT
1.96 V (261h)        VCCMNT   <   2.65 V
(335h)
LCD display : “36 
− XXX”.  XXX is the input voltage.
* Reference value : This value is around 261 to
334.
37. CHGMNT voltage during charging display (when
CHGMNT = ON)
Command
: 37
Operation
: The CHGMNT voltage that is inputted by the
charging sequence is displayed. (Voltage when
CHGMNT = ON)
* Valid voltage of BATTMTN
5.0 V (156h)        BATTMTN   <   1.90 V
(24Dh)
LCD display : “37 
− XXX”.  XXX is the input voltage.
* Reference value : This value is around 156 to
24C.
38. CHGMNT voltage during charging display (when
CHGMNT = OFF)
Command
: 38
Operation
: The CHGMNT voltage that is inputted by the
charging sequence is displayed. (Voltage when
CHGMNT = OFF)
* Valid voltage of BATTMTN
BATTMTN   <   1.90 V (24Dh)
LCD display : “38 
− XXX”.  XXX is the input voltage.
* Reference value:  This value is around 0 to 24C.
39. (intentionally left blank)
40. Charging status display
Command
: 40
Operation
: Charging status display
LCD display : “40 
− XXX”.  XXX is the charging status data.
* Contents of the charging status display
00h : State waiting for starting of charging.
01h : Continuous charging is in progress.
02h : Full charged judgment processing is in
progress.
03h : Supplementary charging of 1 hour is in
progress.
04h : Normal charging is complete.
05h : The 1 hour timer has ended.
06h : The 12 hour timer has ended.
07h : Charging the low voltage battery is in
progress during the continuous charging.
10h : Charging is terminated due to the
charging condition error.
11h : Charging is terminated due to the
abnormal voltage during continuous
charging.
12h : Charging is terminated due to the
abnormal voltage when full charged
condition is detected.
13h : Charging is terminated due to the
abnormal voltage during the
supplementary charging.  (Or normal
end.)
14h : Charging is terminated due to abnormal
voltage of 8.6 V or more of battery
voltage when fully charged.
15h : Charging is terminated due to abnormal
voltage of 5.0 V or less battery voltage
when fully charged.
<
=
<
=
6-17
41. BATT switch check and BATTYPE check
Command
: 41
LCD display : “41 
− m n”
m : BATT switch = “1” (Already connected state)
or “0” (Not connected yet state) display.
m : BATTYPE = “1” (Lithium-ion battery) or “0”
(Other batteries than the lithium-ion battery)
display.
6-18E
MEMO
Page of 122
Display