Sony BDP-S7200 Service Manual ▷ View online
1-2-9 In case of BU assy replacement:
1. OP related data for new assy is controlled by BU factory
2. All of data is recorded into a barcode label
3. The label is put on the assy
4. Service parts will be followed
5. In service, the data should be read out from problem assy
6. The read data should be saved to new assy
1. OP related data for new assy is controlled by BU factory
2. All of data is recorded into a barcode label
3. The label is put on the assy
4. Service parts will be followed
5. In service, the data should be read out from problem assy
6. The read data should be saved to new assy
1-2-10. Fact fi nding:
1. The label is “DATA MATRIX” format
2. The number of data is 91 words
3. The method of reading and saving is required when BU and main board are replaced.
1. The label is “DATA MATRIX” format
2. The number of data is 91 words
3. The method of reading and saving is required when BU and main board are replaced.
1-2-11. New service method
1. All of BU data on the barcode label is shot by digital camera in order to make a JPEG fi le of BU data.
2. Application software in the PC makes digital data from JPEG fi le.
3. The converted data is stored to USB memory.
4. The USB memory is connected to BDP 8G unit.
5. In service mode, there is a command to save the data from USB memory to board memory.
1. All of BU data on the barcode label is shot by digital camera in order to make a JPEG fi le of BU data.
2. Application software in the PC makes digital data from JPEG fi le.
3. The converted data is stored to USB memory.
4. The USB memory is connected to BDP 8G unit.
5. In service mode, there is a command to save the data from USB memory to board memory.
1-2-12 . BU Data
Description: BDPRdec.exe
When instruction to PC, password is required. The password will be supplied to only service HQ, and service center name,
q’ty and all of software registered information should be maintained by service HQ, and Video will ask to report the
registration information.
q’ty and all of software registered information should be maintained by service HQ, and Video will ask to report the
registration information.
Shoot the barcode
Format is JPEG
Format is JPEG
Save the TEXT data
USB device is connected
to symbol on the
rear unit, and the TEXT
data as new data is
loaded to unit by service
mode.
to symbol on the
rear unit, and the TEXT
data as new data is
loaded to unit by service
mode.
Application Software
Data convert from
JPEG
Data convert from
JPEG
TEXT
A
A
1-9
BDP-S7200
1-10E
BDP-S7200
2.0 DEVICE ID INFORMATION
2.1 Procedure to check “Device ID”
1. From XMB(home menu), select “Setup”
2.Select “System Setting” and press “ ENTER” key
3. Select “System Information” and push “ENTER” key.
4. Device ID is shown on the display. (figure 2.1)
DEVICE ID : XX:XX: XX:XX: XX:XX <= 12 digit
If you need deleting of customer’s registration, please contact to service HQ with Device ID information.
BDP BX620/S6200
(figure 2.1)
2-1
BDP-S7200
SECTION 2
DISASSEMBLY
• This set can be disassembled in the order shown below.
2-1. DISASSEMBLY FLOW
2-2. SIDE PANEL AND TRAY COVER ASSY
SET
2-2 REAR PANEL AND
TRAY COVER ASSY
TRAY COVER ASSY
(Page 2-1)
2-3 TOP PANEL, FR-1306 BOARD, FL-1306
BOARD AND WLAN
MODULE
BOARD AND WLAN
MODULE
(Page 2-2)
2-4 SWITCHING
REGULATOR
(Page 2-2)
REGULATOR
(Page 2-2)
2-5 MB-1302 BOARD
(Page 2-3)
2-6 BD DRIVE AND FOOT
(Page 2-3)
2-2
BDP-S7200
䐡Two screws +BV3(3-CR)
䐠Harness (PM-1004)
䐢Switching
regulator
regulator
䐣PS i
l t
䐣PS insulator
䐟Release
PS insulator Clip
PS insulator Clip
䐟Si h
k
d lid
䐟Six hook and slide
䐠Top Panel
䐦Flexible flat cable
(FIM-1004)
(FIM-1004)
䐪Ten screws
+BV3(3-CR)
䐩FL-1306
䐫Case Top
䐢Fl ibl fl t
bl (WIM 1001)
䐨FR 1306
䐧Flexible flat cable
(FIF-1001)
(FIF-1001)
䐣WLAN Module
䐤Four screws +BV3(3-CR)
䐢Flexible flat cable (WIM-1001)
䐡One screw +BV3(3-CR)
䐥Earth Plate USB
䐨FR-1306
(FIF 1001)
2-3. TOP PANEL, FR-1306 BOARD, FL-1306 BOARD AND WLAN MODULE
2-4. SWITCHING REGULATOR