Sony SLT-A77 / SLT-A77K / SLT-A77M / SLT-A77Q / SLT-A77V / SLT-A77VK / SLT-A77VM / SLT-A77VQ Service Manual ▷ View online
Sony Corporation
Auto-ADJ
Ver. 3.0 2015.03
(ENGLISH)
For adjusting these models, the Adjust manual and the Adjust station are required.
For details of installing the Adjust station and the Adjust manual, please refer to the Service manual ADJ of
HDR-TG5/TG5E/TG5V/TG5VE/TG7VE.
For details of installing the Adjust station and the Adjust manual, please refer to the Service manual ADJ of
HDR-TG5/TG5E/TG5V/TG5VE/TG7VE.
Adjust manual Installation
Note 1: Be sure to install Adjust station first.
Note 2: Do not change the initially set folder to which the program is forwarded to.
Note 2: Do not change the initially set folder to which the program is forwarded to.
Note 3: To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
Install the Adjust manual of the DSC-WX50 series in advance.
1. Download the Adjust manual (SLT-A77V_Series_AM_Ver_
□.□_x64.zip) from TISS home page.
2. Double-click
Setup.msi.
3. The installation window appears.
Click [Next]. Adjust manual installation starts.
4. The widow to choose the destination folder of the Adjust manual program appears.
Click
Click
[Next].
5. When Adjust manual is installed normally, the confirmation window appears.
Click [Close]. The installer is closed.
(JAPANESE)
これらの機種で調整を行なうには,アジャストマニュアルとアジャストステーションが必要です。
アジャストマニュアルとアジャストステーションのインストール方法詳細は,HDR-TG5/TG5E/TG5V/TG5VE/TG7VEの
ADJ編を参照してください。
アジャストマニュアルとアジャストステーションのインストール方法詳細は,HDR-TG5/TG5E/TG5V/TG5VE/TG7VEの
ADJ編を参照してください。
アジャストマニュアルインストール手順
注意1: インストールは必ず Adjust station を先に行なってください。
注意2: 転送先フォルダは初期設定より変更しないでください。
注意2: 転送先フォルダは初期設定より変更しないでください。
注意3: この機種で仕向け設定を行うには,DSC-WX50シリーズの Adjust manual がインストールされている必要があります。
先に DSC-WX50 シリーズの Adjust manual をインストールしてください。
1. TISSホームページより,Adjust manual (SLT-A77V_Series_AM_Ver_□.□_x64.zip) をダウンロードします。
2. Setup.msiをダブルクリックします。
3. インストーラー画面が表示されます。
2. Setup.msiをダブルクリックします。
3. インストーラー画面が表示されます。
[Next] ボタンをクリックしてください。アジャストマニュアルのインストールを開始します。
4. 転送先フォルダを選択する画面が表示されます。
[Next] ボタンをクリックしてください。
5. インストールが完了すると,画面が表示されます。
[Close] ボタンをクリックしてください。インストールが終了します。
9-834-614-59
SLT-A77/A77K/A77L/A77M/A77Q/A77V/A77VK/A77VL/A77VM/A77VQ_ADJ
Ver.
Date
History
Contents
S.M. Rev.
issued
1.0
2011.09
Official Release
—
—
1.1
2011.10
Revised-1
(A1 11-247)
(A1 11-247)
Replacement of the previously issued SERVICE MANUAL 9-834-614-51.
• Change of Adjust manual.
Version of Adjust manual has been changed from Ver_1.0 to Ver_1.1.
• Modification of Usage and Diag ercord.
• Modification of Center Adj.
• Modification of Level Adj.
• Modification of Aori Adj (Using the Alignment Tester).
• Modification of Aori Adj (Using the Adjustment Unit).
• Modification of Tebure Revise Adj.
• Modification of Tebure Sensitive Adj.
• Modification of Gain Adj.
• Modification of Defect Detection.
• Modification of High Temp Defect Detection.
• Modification of WB Adj.
• Modification of Hitomi Adj.
• Modification of Sokkan Check (Using the AF chart).
• Modification of Sokkan Check (Using the 40 inch monitor).
• Modification of Flatness Adjustment.
• Modification of EDF Adj (Using the AF chart).
• Modification of EDF Check/Shift (Using the AF chart).
• Modification of EDF Adj (Using the 40 inch monitor).
• Modification of EDF Check/Shift (Using the 40 inch monitor).
• Modification of EVF WB ADJ.
• Modification of EVF OLED Temperature sensor Adj.
• Modification of Destination data write.
• Change of Adjust manual.
Version of Adjust manual has been changed from Ver_1.0 to Ver_1.1.
• Modification of Usage and Diag ercord.
• Modification of Center Adj.
• Modification of Level Adj.
• Modification of Aori Adj (Using the Alignment Tester).
• Modification of Aori Adj (Using the Adjustment Unit).
• Modification of Tebure Revise Adj.
• Modification of Tebure Sensitive Adj.
• Modification of Gain Adj.
• Modification of Defect Detection.
• Modification of High Temp Defect Detection.
• Modification of WB Adj.
• Modification of Hitomi Adj.
• Modification of Sokkan Check (Using the AF chart).
• Modification of Sokkan Check (Using the 40 inch monitor).
• Modification of Flatness Adjustment.
• Modification of EDF Adj (Using the AF chart).
• Modification of EDF Check/Shift (Using the AF chart).
• Modification of EDF Adj (Using the 40 inch monitor).
• Modification of EDF Check/Shift (Using the 40 inch monitor).
• Modification of EVF WB ADJ.
• Modification of EVF OLED Temperature sensor Adj.
• Modification of Destination data write.
Yes*
1.2
2011.11
Revised-2
(A2 11-286)
(A2 11-286)
Replacement of the previously issued SERVICE MANUAL 9-834-614-52.
• Change of Adjust manual.
Version of Adjust manual has been changed from Ver_1.1 to Ver_1.2.
・ Modification of SS Adj.
• Change of Adjust manual.
Version of Adjust manual has been changed from Ver_1.1 to Ver_1.2.
・ Modification of SS Adj.
Yes*
1.3
2011.11
Revised-3
(A3 11-288)
Replacement of the previously issued SERVICE MANUAL 9-834-614-53.
• Modification of EDF Adj (Using the AF chart).
• Modification of EDF Check/Shift (Using the AF chart).
• Modification of AF Micro Adj.
• Chage of List of service tools.
• Modification of EDF Adj (Using the AF chart).
• Modification of EDF Check/Shift (Using the AF chart).
• Modification of AF Micro Adj.
• Chage of List of service tools.
Yes*
1.4
2012.03
Revised-4
(A4 11-476)
Replacement of the previously issued SERVICE MANUAL 9-834-614-54.
• Change of Adjust manual Version of Adjust manual has been changed
from Ver_1.3 to Ver_1.4.
• Change of Prepare Adj.
• Change of AF/Iris PI,RPS Adj.
• Correction of Center Adj.
• Correction of Gain Adj.
• Correction of SS Adj.
• Correction of NonLinear Elec shut Adj.
• Correction of Hitomi Adj.
• Correction of Flatness Adjustment.
• Modification of Destination data write.
• Change of Adjust manual Version of Adjust manual has been changed
from Ver_1.3 to Ver_1.4.
• Change of Prepare Adj.
• Change of AF/Iris PI,RPS Adj.
• Correction of Center Adj.
• Correction of Gain Adj.
• Correction of SS Adj.
• Correction of NonLinear Elec shut Adj.
• Correction of Hitomi Adj.
• Correction of Flatness Adjustment.
• Modification of Destination data write.
Yes*
1.5
2012.04
Revised-5
(A5 12-052)
(A5 12-052)
Replacement of the previously issued SERVICE MANUAL 9-834-614-55.
• Change of Adjust manual Version of Adjust manual has been changed
• Change of Adjust manual Version of Adjust manual has been changed
from Ver_1.4 to Ver_1.5.
• Modification of Center Adj.
• Modification of Level Adj.
• Modification of Destination data write.
• Modification of Level Adj.
• Modification of Destination data write.
Yes*
1.6
2012.06
Revised-6
(A6 12-105)
Replacement of the previously issued SERVICE MANUAL 9-834-614-56.
• Change of Adjust manual Version of Adjust manual has been changed
• Change of Adjust manual Version of Adjust manual has been changed
from Ver_1.5 to Ver_1.6.
• Addition of SLT-A77K/A77M/A77VM.
• Modification of Destination data write.
• Modification of Destination data write.
Yes*
1.7
2013.07
Revised-7
(A7 13-046)
Replacement of the previously issued SERVICE MANUAL 9-834-614-57.
• Addition of SLT-A77L/A77VL.
• Addition of SLT-A77L/A77VL.
Yes*
983461459.pdf
2015C08-1
© 2015.03
Published by Sony Techno Create Corporation
SLT-A77/A77K/A77L/A77M/A77Q/A77V/
A77VK/A77VL/A77VM/A77VQ
*: S.M. revised only top cover.
Revision History (1/2)
Revision History (2/2)
SLT-A77/A77K/A77L/A77M/A77Q/A77V/A77VK/A77VL/A77VM/A77VQ_ADJ
Ver.
Date
History
Contents
S.M. Rev.
issued
3.0
2015.03
Revised-8
(A8 14-173)
(A8 14-173)
Replacement of the previously issued SERVICE MANUAL 9-834-614-58.
• Change of Adjust manual.
Version of Adjust manual has been changed from Ver_1.6 to Ver_3.0.
• Modification of HASP Key authentication.
• Modification of “Destination data write”.
• Modification of “NonLinear Elec shut Adj”.
• Change of Adjust manual.
Version of Adjust manual has been changed from Ver_1.6 to Ver_3.0.
• Modification of HASP Key authentication.
• Modification of “Destination data write”.
• Modification of “NonLinear Elec shut Adj”.
Yes*
*: S.M. revised only top cover.
Display