Sony SAL85F14Z Service Manual ▷ View online

HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP04
Anti-diffusion agent (A-20): J-6082-611-A
Adhesive bond (B-10):
J-6082-612-A
1.
Apply the anti-diffusion agent (A-20) to indicated portion of 1st lens holder A.
2.
Install the 1st ball frame (A) lens block to the 1st lens holder A in orders of 1 to 4.
Note:
After installing the G3 stopper, apply the adhesive bond (B-10) between G3 stopper and 1st lens holder A. (One place in the
width of 10mm)
HELP05
Adhesive bond (B-40): J-6082-614-A
Apply the adhesive bond (B-40) to the tips of two screws shown in figure and tighten the screws.
2
1
3
4
G2 Stopper
G3 Stopper
Lens (G2)
Lens (G3)
1st Lens Holder A
Apply the anti-diffusion agent (A-20) (All round)
Apply the adhesive bond (B-40)
Apply the adhesive bont (B-10)
(One place in the width of 10mm)
1st Lens Holder A
G3 Stopper
HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP06
Adhesive bond (B-40): J-6082-614-A
Apply the adhesive bond (B-40) to the tips of three screws shown in figure and tighten the screws.
Apply the adhesive bond (B-40)
Apply the adhesive 
bond (B-40)
HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP07
Adhesive bond (LOCTITE 460)
Note:
Use the adhesive bond (LOCTITE 460) or an equivalent article.
Do not use what becomes white after drying like quick-drying glue.
Anti-diffusion agent (A-20): J-6082-611-A
Grease (G-85):
J-6082-626-A
1.
Apply the adhesive bond (LOCTITE 460) to the tip of screwed portion of stopper screw and tighten the stopper screw.
2.
Apply the grease (G-85) and the anti-diffusion agent (A-20) to the indicated portions of lens mount.
3.
Combine the pins of preset ring and aperture operate plate unit, install the lens mount rivetting block.
4.
Tighten four screws catercorner shown in figure.
Lens Mount Rivetting Block
Screws
Screws
Preset Ring
Apply the anti-diffusion agent (A-20) (All round)
Apply the grease (G-85) to the hole of coupler
Apply the grease (G-85) 
(3 locations of hood fixed tabs)
Apply the adhesive bond
(LOCTITE 460)
HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP08
Grease (G-35): J-6082-621-A
1.
Apply the grease (G-35) to the indicated portion of coupler.
2.
Select a coupler adjustment washer of same thickness as that of back adjustment washer used in the flange back adjustment and
install it.
Part No.
Description
Thickness
2-684-057-01
Coupler Adjustment Washer A
0.05 mm
2-684-058-01
Coupler Adjustment Washer B
0.07 mm
2-684-059-01
Coupler Adjustment Washer C
0.1 mm
2-684-060-01
Coupler Adjustment Washer D
0.2 mm
2-684-061-01
Coupler Adjustment Washer E
0.5 mm
Coupler Adjustment Washer
Coupler
Apply the grease (G-35) 
(All surroundings of addendum)