SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
HELP24
Adhesive bond (B-40): J-6082-614-A
1.
While drawing out the flexible PWB and harness of stator through the flexible PWB threading hole of front holding tube, install the
front holding tube block.
2.
Apply two drops of adhesive bond (B-40) to the tips of eight screws and fix the front holding tube block with eight screws.
Note:
Tighten four screws diagonally first and then the rest four screws diagonally.
Apply the 
adhesive bond (B-40)
Flexible PWB threading hole
of front holding tube
Flexible PWB threading hole
of front holding tube
Front Holding Tube Block
Tighten four screws diagonally
Tighten the rest four 
screws diagonally
Flexible PWB and harness of stator
Flexible PWB and harness of stator
HELP
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
HELP25
Adhesive bond (B-10):
J-6082-612-A
Adhesive bond (LOCTITE 460)
Note:
Use the adhesive bond (LOCTITE 460) or the equivalent.
Do not use the instant glue that becomes white when dried.
1.
Set the flexible substrate setting tape, FH flexible PC board and click plate to the front holding tube and fix them with washers and
screws.
2.
Apply the adhesive bond (B-10) to the location indicated in the figure.
Note:
If too much adhesive bond is applied, it flows in the gap in the click plate and FH flexible PC board and causes no conduction.
3.
Affix the FHB shielding tape as shown in the figure.
4.
Apply the adhesive bond (LOCTITE 460) to the indicated portion of front holding tube.
5.
Install the focus hold button and the focus hold button base and fix them with a scotch tape until the adhesive bond dries.
Flexible Substrate Setting Tape
FH Flexible PC Board
Front Holding
Tube
Click Plate
Click Plate
Screw
Washer
Washer
Affix the 
FHB shielding tape
Apply the 
adhesive bond
(LOCTITE 460)
Focus Hold
Button Base
Focus Hold Button,
Focus Hold Button Base
Focus Hold
Button
Scotch tape, 
etc.
Scotch tape, 
etc.
Apply the 
adhesive bond 
(B-10)
HELP
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
HELP26
1.
Affix the FH flexible setting tape and MR sensor setting tape to the indicated portion of FH flexible PC board.
2.
Affix the FH flexible setting tape to the indicated portion of front holding tube.
3.
Affix the FH flexible PC board to the front holding tube, referring to the affixing reference.
FH Flexible Setting Tape
FH Flexible Setting Tape
FH Flexible PC board
Align the edges
with the stair.
Front Holding Tube
Front Holding Tube
MR Sensor Setting Tape
FH Flexible PC board
HELP
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
HELP27
1.
Affix the DV encoder flexible PC board to the front holding barrel along the affixing reference as shown in the figure below.
Front Holding
Barrel
Front Holding
Barrel
DV Encoder Flexible 
PC Board
DV Encoder Flexible 
PC Board
DV Encoder Flexible 
PC Board
Align the leading edge flexible
board with the corner crossed
by two arrow lines.
Do not peel off the detached
sheet on the flexible board  at 
the upper side above the line
at this moment. 
Affix the flexible board,
leaving the curve at four corners.