5-45
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
If not adjusted, perform the steps below.
1)
Remove the MR sensor holding plate, correct the position of MR sensor holding plate block as shown in Fig. 5-9-21.
2)
Install the MR sensor holding plate, perform the MR waveform inspection again.
3)
Repeat steps 1) and 2) until the inspection OK.
4)
After completing the adjustment, apply the adhesive bond (B-10) to the tip of two screws.
Fig.5-9-21
3. Motor Assembly Inspection
The following pop-up window is one example.
Fig.5-9-22
If the NG judgment continues three times in the motor assembly inspection, perform the MR waveform inspection.
When the MR waveform inspection is OK, perform the adjustment of MR sensor.
When the MR waveform inspection is NG, replace the ultrasonic motor unit.
4. DMF Ring Rotation Detector SW Inspection
The following pop-up window is one example.
Fig.5-9-23
Deformation or damage of MF rotation detector switch plate block.
Installation position of MF rotation detector switch plate block.
Apply the adhesive bond (B-10).
MR Sensor Holding Plate
A
B
MR Sensor Holding Plate
MR Sensor Holding Plate
tweezers
Bend about 3
°.
Be careful not to bend this part.
If the ellipse of MR sensor waveform drops 
to the lower right side, bend the part B 
by 1, 2
° than the part A.
5-46
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
5-10. FINISHED INSPECTION (ActuatorChecker)
5-10-1.
Finished inspection (ActuatorChecker)
Equipment
Personal Computer
Finished Inspection JIG (AC100 V only)
Lens Adjustment Program (ActuatorChecker)
1. Preparations
1)
 Connected to equipment with checking lens. (Refer to Fig. 5-1-25 of Section 5-1-3.)
2)
Start up of “ActuatorChecker”.
3)
Click [Set up], and perform the initial setting. (Refer to Section 5-1-4.)
2. Checking Method
1)
Click [START].
Fig.5-10-1
2)
The Serial window appears. Input the lens serial number.
Note:
When [OK] is clicked without inputting the serial number, the date executed is displayed on the completion window of each item.
     Fig.5-10-2
3)
The following window appears, press down the ENTER key.
Fig.5-10-3
4)
It starts from the ROM Data inspection, and it advances to the CPU Mode Standby Current check by the automatic operation.
5)
When the CPU Mode Standby Current Check finishes normally, the Lens Stating Circuit Check is started, change AF-MF switch to
MF.
Fig.5-10-4
5-47
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
6)
When the Lens Starting Circuit Check finishes normally, the DMF Ring Rotation Detect Switch Check is started, set the focus to near
position and press down the ENTER key.
Fig.5-10-5
7)
When the DMF Ring Rotation Detect SW Check finishes normally, the Focus Adjustment Point Check is started, set the focus to
infinity position and press down the ENTER key.
Fig.5-10-6
8)
When the Focus Adjustment Point Check finishes normally, the Focus Pattern Check is started, set the focus to near position at about
5 sec.
Fig.5-10-7
9)
Next, set the focus to infinity position at about 5 sec.
Fig.5-10-8
10) When the Focus Pattern Check finishes normally, the Zoom Adjustment Point Check is started, set the zoom to WIDE position and
press down the ENTER key.
Fig.5-10-9
11) When the Zoom Adjustment Point Check finishes normally, the Zoom Pattern Check is started, set the zoom to TELE position and
press down the ENTER key.
Fig.5-10-10
12) Next, set the zoom to WIDE position at about 10 sec at a stretch.
Fig.5-10-11
5-48
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
13) Next, set the zoom to TELE position at about 10 sec at a stretch.
Fig.5-10-12
14) When the Zoom Pattern Check finishes normally, the E2PROM Initial Value Check is started automatically.
15) When the E2PROM Initial Value Check finishes normally, the MR D/A Offset Adjustment is started, set the focus to near position at about 3 sec.
Fig.5-10-13
16) When the MR D/A Offset Adjustment finishes normally, the Dv Pulse Check is started, set the focus to infinity position and press
down the ENTER key.
Fig.5-10-14
17) Next, set the focus to near position at a stretch and press down the ENTER key.
Fig.5-10-15
18) Next, set the focus to infinity position at a stretch and press down the ENTER key.
Fig.5-10-16
19) When the DV Pulse Check finishes normally, the Focus Pattern Switching Position Adjustment is started, set the focus to near
position at about 3 sec at a stretch.
Fig.5-10-17
20) When the Focus Pattern Switching Position Adjustment finishes normally, the Motor Control Coefficient Adjustment is started automatically.
21) When the Motor Control Coefficient Adjustment finishes normally, the Focus Hold Button Check is stavted, push hold button once softly.
Fig.5-10-18