HELP
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
HELP43
Grease (G-15):
J-682-619-A
Grease (G-85):
J-682-626-A
Grease (G-115): J-682-627-A
Apply the grease (G-15), grease (G-85) and grease (115) to the indicated portions of focus connect ring.
Apply the grease (G-85)
Apply the grease (G-15)
Apply the grease (G-115)
Focus Connect Ring
HELP
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
HELP44
Adhesive bond (B-10): J-6082-612-A
1.
Affix the flexible substrate set tape and insulating tape to the locations shown in the figure of main frame flexible PC board block.
2.
Fold the main frame flexible board block as instructed.
3.
Affix the flexible substrate set tape A, flexible substrate set tape B, flexible substrate set tape C and flexible substrate set tape D to the
locations shown in the figure of bearing press fitting block.
4.
Affix the main flexible PC board block to the bearing press fitting block, threading the DV encoder block of main flexible PC board
block in the hole of bearing press fitting block. When affixing, use “a” and “b” as references.
Affix the DV encoder block in parallel with the edge surface of bearing press fitting block.
Fold upward
Fold upward
Main Flexible PC Board Block
Fold downward
Fold downward
Fold downward
Fold downward
Fold downward
Flexible Substrate
Set Tape F 
(5x10.5mm)
Insulating Tape 
(11x15mm)
Flexible Substrate
Set Tape E 
(7.5x14mm) 
Flexible Substrate
Set Tape G 
(6.5x7.5mm) 
Flexible Substrate Set Tape A
Flexible Substrate Set Tape C
Flexible Substrate Set Tape D
Flexible Substrate Set Tape B
Bearing Press Fitting Block
(6.2x10mm)
Hole
Zoom Encoder
DV Encoder 
a
b
Main Flexible PC Board Block
Bearing Press Fitting Block
HELP
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
5.
Apply the adhesive bond (B-10) to the portions indicated in the figure.
HELP45
Grease (G-115):
J-6082-627-A
Anti-diffusion agent (A-20): J-6082-611-A
1.
Apply the anti-diffusion agent (A-20) to the indicated portion of bearing press fitting block.
2.
Apply the grease (G-115) to the indicated portion of bearing press fitting block.
Main Flexible Board Block
Apply the adhesive bond (B-10)
Apply the adhesive bond (B-10)
Apply the anti-diffusion agent 
(A-20)
Bearing Press Fitting Block
Bearing Press Fitting Block
Apply the grease (G-115)
(Press-fitted portion of focus ring)
Apply the grease (G-115)
(Press-fitted portion of focus connect ring)  
Apply the grease (G-115)
(Focus inner gear)
HELP
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
HELP46
Adhesive bond (B-10): J-6082-612-A
1.
Install the 4 group lens block to the focus cam tube block.
2.
Tighten the 4th lens hold washer shown in figure.
3.
Apply the adhesive bond (B-10) to the 2 locations of all circumference of 4 group lens block and 4th lens hold washer.
4 Group Lens Block
Apply the adhesive bond (B-10)
(2 locations of all circumference, width 5mm)
Apply the adhesive bond (B-10)
(2 locations of all circumference, width 5mm)
4th Lens Holder Block
Ver 1.1  2006.12
Page of 97
Display