4-39
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
 DT 16-80mm F3.5-4.5 ZA)
4-10-3. Zoom Brush Pattern Check (Zoom Brush Pattern)
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Zoom Pattern]
.
Fig.4-10-16
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-10-17
3)
The message “Move ZOOM to TELE position. Then push [ENTER].” is displayed on the pop-up window.
Set the zoom to the tele position and press down the ENTER key.
Fig.4-10-18
4-40
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
 DT 16-80mm F3.5-4.5 ZA)
4)
When the tele position check finishes normally, the message “Move ZOOM to WIDE position at about 10sec.” is displayed on the
pop-up window.
Set the zoom to the wide position and press down the ENTER key.
Fig.4-10-19
5)
When the wide position check finishes normally, the message “Reverse ZOOM to TELE position at about 10sec.” is displayed on the
pop-up window.
Set the zoom to the tele position and press down the ENTER key.
Fig.4-10-20
6)
When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-10-21
3. In case of error display in the Zoom Pattern (Tele position (first try))
1)
When the error display and the NG display appear to the pop-up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
Fig.4-10-22
Fig.4-10-23
2)
 Although the lens is positioned at the tele position, if “NG” appears, confirm or perform the following.
• 4-10-1. Zoom Brush Position Adjustment (Search Zoom Adjustment Point)
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
• Rotating operation error of the focus ring (rotation speed is not suitable at a regulated speed.).
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-41
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
 DT 16-80mm F3.5-4.5 ZA)
4. In case of error display in the Zoom Pattern (WIDE position)
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
wide position can be done in more than 5 seconds and no more than 10 seconds.
• When the zoom pattern error
Fig.4-10-24
Fig.4-10-25
• When the lens does not reach the wide end infinity position seconds.
Fig.4-10-26
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
5. In case of error display in the Zoom Pattern (TELE position (second try))
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
tele position can be done in more than 5 seconds and no more than 10 seconds.
• When the zoom pattern error
Fig.4-10-27
Fig.4-10-28
• When the lens does not reach the tele end infinity position seconds.
Fig.4-10-29
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-42
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
 DT 16-80mm F3.5-4.5 ZA)
4-11. FOCUS BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK
4-11-1. Focus Brush Position Adjustment (Search Focus Adjustment Point)
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker)
• Adhesive bond (B-10)
1. Preparations
1)
Remove the zoom rubber ring and zoom hold ring from the lens unit.
Note:
After removing the zoom hold ring, do not move the zoom barrel in the arrow direction. If moved, the zoom brush will be
deformed.
Fig.4-11-1
2)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
3)
Start up of “ActuatorChecker.exe”.
4)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
Zoom Rubber Ring
Screw
Screw
Screw
Zoom Hold Ring
Zoom Barrel