4-15
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
4-4-2. Flange Back (f’F) Adjustment
Equipment
• 1000 mm Collimator
• Flange Back Tester
• A-mount Attachment
• Flange Back Gauge (43.50mm)
Note:
“4-4-3. Focus-shift Adjustment” must be completed before performing the Flange Back (f’F) Adjustment.
1. Preparations
1)
Remove the focus rubber.
2. Adjusting Method
1)
Perform “4-4-1. Flange Back (f’F) Check”, and check that the flange back (f’F) of the checking lens is out of specification of Table
4-4-1.
2)
Set the zoom ring of the checking lens to Tele end position (focal length: 18 mm)
3)
Set the support barrel assembly of the checking lens to over infinity position.
4)
Turn the knob of the flange back tester until the chart image is the sharpest while looking through the microscope.
5)
Calculate the shift amount (x) using the following formula.
Shift amount (x) = Measured value - 44.70 mm
Measured value: Flange back f’F at over infinity position (focal length: 18 mm)
x = Shift-amount that should be adjusted by the back adjustment washer.
6)
Adjust the back adjustment washer thickness according to the result of step 5). (Refer to Table 4-4-2.)
Note:
Be sure to measure the thickness of the back adjustment washer by micrometer or vernier caliper.
• When the shift-amount is a negative value: Decrease the back adjustment washer thickness by the amount of shift amount (x).
• When the shift-amount is a positive value: Increase the back adjustment washer thickness by the amount of shift amount (x).
Back adjustment washer
Parts No.
t (mm)
A
2-886-768-01
0.5
B
2-886-781-01
0.3
C
2-886-782-01
0.2
D
2-886-783-01
0.1
E
2-886-784-01
0.05
F
2-886-785-01
0.03
Table 4-4-2
7)
Assemble the back adjustment washer, and perform the “4-4-1. Flange Back (f’F) Check” again.
4-16
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
4-4-3. Focus-shift Adjustment
This section describes the check/adjustment of focus-shift amount resulting change of the focal-length by zooming.
Equipment
• 1000 mm Collimator
• Flange Back Tester
• A-mount Attachment
• Flange Back Gauge (43.50mm)
Adjusting Method
Note:
About the insulating tape in the sentence. When shipping it, Mending tape (2-886-794-01) is used.
1)
Perform “4-4-1. Focus-shift/Flange Back (f’F) Check and Optical Axis Adjustment”, and check that the flange back (f’F) of the
checking lens is out of specification of Table 4-4-1.
2)
Set the zoom ring of the checking lens to Wide end position (focal length: 11 mm).
3)
Set the support barrel assembly of the checking lens to infinity position (center of the “L” mark index). (Fig. 4-4-6)
4)
Turn the knob of the flange back tester until the chart image is the sharpest while looking through the microscope, and check the
flange back (f’F).
5)
Set the zoom ring of the checking lens to Tele end position (focal length: 18 mm).
6)
Peel off the two insulating tapes. (Fig 4-4-6)
7)
Turn the support barrel assembly until the chart image is the sharpest.
8)
Set the focus gear barrel to the infinity position (infinity end) while maintaining the support barrel assembly so as not to rotate it.
Affix the two insulating tapes. (Fig 4-4-6)
9)
Perform steps 2) to 8) until the specification of focus-shift amount (difference between the maximum flange back (f’F) and minimum
flange back (f’F)) of the checking lens is met.
Focus-shift  = Maximum flange back (f’F) reading - Minimum flange back (f’F) reading
Specification
Focus-shift: Less or equal 0.03 mm
Fig4-4-6
3
10
m
ft
3
2
1.5
1
0.7
0.5
L mark index
Index
Focus gear barrel
Support barrel assembly
Insulating Tape (Two areas)
Align the center
4-17
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
4-5.
LENS ROM CHECK
Note:
If dialog box of error code appears during the checking, check the reason of error referring to page 4-22.
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1)
Connect the checking lens to the camera.
2)
Start the lens adjustment program “LensAdjustment.exe” referring to “4-1-2. Lens Adjustment Program”.
Fig. 4-5-1
2. Checking Method
1)
Click the 
[Connect]
 button on the lens adjustment program.
Note:
Click the 
[End]
 button to disconnect the USB connection, then lens adjustment program will terminate.
2)
Check that the display of “Lens Code” and “Model Name” is correct.
Note:
Zoom and focus position setting is not required.
Fig. 4-5-2
3)
Click the 
[End]
 button to terminate the lens adjustment program.
4)
Turn the POWER switch of the camera to OFF.
Ver 1.3  2007.04
4-18
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
4-6.
ZOOM BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK
Note:
If dialog box of error code appears during the checking or adjustment, check the reason of error referring to page 4-22.
4-6-1. Zoom Brush Position Check
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1)
Connect the checking lens to the camera.
2)
Start the lens adjustment program “LensAdjustment.exe” referring to “4-1-2. Lens Adjustment Program”.
Fig. 4-6-1
2. Checking Method
1)
Click the 
[Connect]
 button on the lens adjustment program.
Note:
Click the 
[End]
 button to disconnect the USB connection, then lens adjustment program will terminate.
Fig. 4-6-2
2)
Click the 
[Zoom]
 button on the lens adjustment program.
3)
Set the zoom position to Tele end, and check that the OK (Green) indicator of “Position” lights as shown in Fig. 4-6-3.
Note:
Lens focus position setting is not required.
Fig. 4-6-3
If the NG (Red) indicator of “Position” lights, check zoom brush and frekipattern is confirmed.
Fig. 4-6-4
4)
Click the 
[Exit]
 button.
5)
Click the 
[End]
 button to terminate the lens adjustment program.
6)
Turn the POWER switch of the camera to OFF.