1-3
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
– ENGLISH –
1-4.  PRECAUTION ON REPLACING THE MB N PLATE AND NDF UNIT
Perform the following procedures for each of the three washers.
Note: Measure the dimensions before replacement of the MB N Plate and NDF Unit according to procedures (1) to (3).
(1) Remove the Imager Block Assy and the IM Adjust Washers (A).
(2) Measure the dimensions (A) of the removed IM Adjust Washers.
SSM height adjustment
measurement JIG
-$
A
+
B
BA
(3) Measure the distance (B) between the surface of the screw hole where the IM Adjust Washers were set and the surface of the E-Mount.
(4) Likewise, measure the dimensions (B’) of each location where IM Adjust Washers of new Cabinet Front are installed.
(5) Calculate the dimension of (A’) of new IM Adjust Washer by using the formula below, and select the washers.
  
Dimension 
(A+B) before replacement – Dimension (B’) of new Cabinet Front
           
= Dimension (A’) of IM Adjust Washer after replacement
(6) Assemble the imager, using the selected IM Adjust Washers.
(7) After assembling is completed, perform the test shooting and confirm that no blur is observed in the peripheral area of shot.
1-5. SELF-DIAGNOSIS FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service 
mode display. Details of the self-diagnosis functions are provided in the 
Instruction manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD 
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the “repaired 
by:”, “block” in which the problem occurred, and “detailed code”of the 
problem.
0 0
3 2
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
E : Corrected by service
engineer
LCD screen
C : Corrected by customer
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Access error
Remove the power source. Reconnect it again and operate your cam-
corder again.
C
1
3
0
3
Access error (External media)
Turn power off and turn power on again.
C
1
3
0
4
Drive fault (External media)
Turn power off and turn power on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “DESTINATION DATA WRITE”.
Note 2: Functions of codes with * mark are not provided in this unit.
(                                            )
*
*
1-4
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Turn power off and turn power on again.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Turn power off and turn power on again.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Turn power off and turn power on again.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Turn power off and turn power on again.
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Turn power off and turn power on again.
E
6
2
1
0
Shift lens initializing failure.
Turn power off and turn power on again.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-6. METHOD OF COPING WITH LENS ERROR].
E
9
1
0
1
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2
Abnormality of flash unit.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of flash unit Temperature 
detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each out-
put of DC/DC converter on IC4301 of VC-650 board with the AC 
adaptor connected DC JACK (J901). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing or back up the 
flash memory
Check the OneNAND of CPU (IC1301 on the VC-650 board).
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-650 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
– ENGLISH –
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
1-6.  METHOD OF COPING WITH LENS ERROR
When lens error is occurred, check the following items.
Lens error codes:
・  E: 61: 30 (Reset position detection error on the stepper iris initializing)
・  E: 62: 11 (Shift lens overheating (Pitch))
・  E: 62: 12 (Shift lens overheating (Yaw))
・  E: 62: 20 (Abnormality of thermistor)
Check items:
1.  Replace the lens.
2.  Replace the VC-650 board or IC1301 on the VC-650 board.
3.  Check that the square wave is appeared below points.
・ BODY_VD_LENS (pin 0 of CN6602 or pin 6 of IC6601 on the MT-076 board)
・ BODY_DATA_LENS (pin qf of CN6602 or pin 4 of IC6602 on the MT-076 board)
・ LENS_DATA_BODY (pin qd of CN6602 or pin 5 of IC6603 on the MT-076 board)
1-5
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
– JAPANESE –
1-1.  修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプターを使用する。
1-2.   VC-650 基板交換時の注意
基板交換時は,下記の点に注意してください。
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB SERIAL No. INPUT」を実行させてくだください。
VC基板の識別について
補修用VC基板には2種類あります。基板を交換する際は,マーカーペンによる識別マークの有無を確認してください。
マーク無し:  FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700U/FS700UK
マーク有り:  FS700R/FS700RH
VC-650 BOARD (SIDE B)
識別マーク
1-3.  Destination Data ファイルの追加について
Adjust manual に含まれる Destination Data ファイルが古い場合, 
「DESTINATION DATA WRITE」 が実行できないことがあります。
その場合は,下記の手順を参考にして, TISS ホームページより新しい Destination Data ファイル を入手してください。 
Note1:  この機種で仕向け設定を行うには,DSC-WX50シリーズの Adjust manual がインストールされている必要があります。
 
 
先に DSC-WX50 シリーズの Adjust manual をインストールしてください。
Note 2:  手順中の画像は実際と異なる場合があります。
1)  使用している Adjust manual の Destination Data ファイルが古い場合, Fig. 1 のようなウインドウが表示される。
 
[OK] ボタンをクリックする。
 
 Fig. 
1
2)  Destination Data Write ウインドウが表示される。 
 
 
 
 
Adjust manual の保持している Destination Data ファイル のバージョンを確認する。 
 
Destination Ver. ウインドウ
3)  TISSホームページにて,新しい Destination Data ファイルを入手したい機種を検索する。 
 
Destination  Data  ファイルが更新されている場合,「Destination  File  For  機種名 .zip」 という名称のファイルが登録されてい
る。 
 (例) Destination File For DSC-WX50.zip
 また,Remarks欄にはこの Destination Data ファイルが対応するバージョンが記載されています。
 Note: バージョンが更新されていなかった場合は,サービスヘッドクォーターへお問い合わせください。
1-6
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
4)  該当機種の Destination Data ファイルをダウンロードし,解凍する。 
 
5)  Adjust manual の Adjust タブにある,「DESTINATION DATA WRITE」 を実行する。
 
[START] ボタンをクリックする。
 
6)  ウインドウ内の [File Update] ボタンをクリックする。
 
– JAPANESE –
7)  ファイルを選択する画面が出るので,追加する Destination Data ファイルを選択し, [開く] ボタンをクリックする。
 
 
8)  ファイルの追加が成功すると, 下記のような画面が出る。
 
 
9)  Destination Ver. ウインドウを確認し,バージョンが更新されていることを確認する。
 
Destination Ver. 
ウインドウ
Page of 112
Display

Click on the first or last page to see other NEX-FS700 / NEX-FS700C / NEX-FS700CK / NEX-FS700E / NEX-FS700EK / NEX-FS700J / NEX-FS700JK / NEX-FS700K / NEX-FS700R / NEX-FS700RH / NEX-FS700U / NEX-FS700UK service manuals if exist.