DOWNLOAD Sony NEX-FS700 / NEX-FS700C / NEX-FS700CK / NEX-FS700E / NEX-FS700EK / NEX-FS700J / NEX-FS700JK / NEX-FS700K / NEX-FS700R / NEX-FS700RH / NEX-FS700U / NEX-FS700UK Service Manual ↓ Size: 20.69 MB | Pages: 112 in PDF or view online for FREE

Model
NEX-FS700 NEX-FS700C NEX-FS700CK NEX-FS700E NEX-FS700EK NEX-FS700J NEX-FS700JK NEX-FS700K NEX-FS700R NEX-FS700RH NEX-FS700U NEX-FS700UK
Pages
112
Size
20.69 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera
File
nex-fs700-nex-fs700c-nex-fs700ck-nex-fs700e-nex-fs.pdf
Date

Sony NEX-FS700 / NEX-FS700C / NEX-FS700CK / NEX-FS700E / NEX-FS700EK / NEX-FS700J / NEX-FS700JK / NEX-FS700K / NEX-FS700R / NEX-FS700RH / NEX-FS700U / NEX-FS700UK Service Manual ▷ View online

– 5 –
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS IDENTIFIED BY MARK 
0 OR DOTTED LINE WITH 
MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST 
ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPO-
NENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS 
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY 
SONY. 
ATTENTION AU  COMPOSANT  AYANT  RAPPORT 
À  LA  SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 
0 SUR LES 
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT 
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REM-
PLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT 
LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES 
SUPPLÉMENTS PUBLIÉS PAR SONY.
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
注意
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer.
1.  Check the area of your repair for unsoldered or poorly-soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or contact high-wattage resistors.
3.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
4.  Look for parts which, through functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
5.  Check the B+ voltage to see it is at the values specified.
6.  Flexible Circuit Board Repairing
•  Set the soldering iron tip temperature to 350 °C approximately.
•  Do not touch the soldering iron on the same conductor of the circuit 
board (within 3 times).
•  Be careful not to apply force on the conductor when soldering or 
unsoldering.
1.  注意事項をお守りください。
 
サービスのとき特に注意を要する個所については,キャビ
ネット,シャーシ,部品などにラベルや捺印で注意事項を
表示しています。これらの注意書き及び取扱説明書等の注
意事項を必ずお守り下さい。
2.  指定部品のご使用を
 
セットの部品は難燃性や耐電圧など安全上の特性を持った
ものとなっています。従って交換部品は,使用されていた
ものと同じ特性の部品を使用して下さい。特に回路図,部
品表に0印で指定されている安全上重要な部品は必ず指定
のものをご使用下さい。
3.  部品の取付けや配線の引きまわしはもとどおりに
 
安全上,チューブやテープなどの絶縁材料を使用したり,
プリント基板から浮かして取付けた部品があります。また
内部配線は引きまわしやクランパによって発熱部品や高圧
部品に接近しないよう配慮されていますので,これらは必
ずもとどおりにして下さい。
4.  サービス後は安全点検を
 
サービスのために取外したネジ,部品,配線がもとどおり
になっているか,またサービスした個所の周辺を劣化させ
てしまったところがないかなどを点検し,安全性が確保さ
れていることを確認して下さい。
5.  チップ部品交換時の注意
 
・  取外した部品は再使用しないで下さい。
 
・  タンタルコンデンサのマイナス側は熱に弱いため交換時
は注意して下さい。
6.  フレキシブルプリント基板の取扱いについて
 
・  半田こてのこて先温度は約350℃に設定してください。
 
・  同一パターンに何度もコテ先を当てないで下さい。(3回
以内)
 
・  パターンに力が加わらないよう注意して下さい。
サービス,点検時には次のことにご注意ください。
– ENGLISH –
– JAPANESE –
UNLEADED SOLDER
This unit uses unleaded solder.
Boards requiring use of unleaded solder are printed with the lead free 
mark (LF) indicating the solder contains no lead.
(Caution:  Some printed circuit boards may not come printed with the 
lead free mark due to their particular size.)
: LEAD FREE MARK
Be careful to the following points to solder or unsolder.
•   Set the soldering iron tip temperature to 350 °C approximately. 
If cannot control temperature, solder/unsolder at high temperature 
for a short time.
Caution:  The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!  
Unleaded solder is more viscous (sticky, less prone to 
flow) than ordinary solder so use caution not to let solder 
bridges occur such as on IC pins, etc.
•   Be sure to control soldering iron tips used for unleaded solder and 
those for leaded solder so they are managed separately. Mixing un-
leaded solder and leaded solder will cause detachment phenomenon.
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(Lead Free)を意味する
レッドフリーマークがプリントされています。
(注意: 基板サイズによっては,無鉛半田を使用していてもレッ
ドフリーマークがプリントされていないものがありま
す)
:レッドフリーマーク
無鉛半田は,下記の点に注意して使用してください。
・  半田こてのこて先温度は約350℃に設定してください。
温度調節が無理な場合は,高温短時間で作業を行ってくだ
さい。
注意:  半田こてを長く当てすぎると,基板のパターン(銅
箔)がはがれてしまうことがありますので,注意して
ください。また,従来の半田よりも粘性が強いため,
IC端子などが半田ブリッジしないように注意してく
ださい。
・  半田こてのこて先は,必ず無鉛半田用と有鉛半田用に分け
て管理してください。
無鉛半田と有鉛半田が混在すると剥離現象が発生してしま
います。
CHEMICALS
Some chemicals used for servicing are highly volatile.
Their evaporation caused by improper management affects your health
and environment, and wastes resources.
Manage the chemicals carefully as follows.
•  Store chemicals sealed in a specific place to prevent from exposure to 
high temperature or direct sunlight.
•  Avoid dividing chemicals into excessive numbers of small containers 
to reduce natural evaporation.
•  Keep containers sealed to avoid natural evaporation when chemicals 
are not in use.
•  Avoid using chemicals as much as possible. When using chemicals, 
divide only required amount to a small plate from the container and 
use up it.
PLASTIC PARTS
Be careful to the following points for plastic parts used in this unit.
•  Use a piece of cleaning paper or cleaning cloth for cleaning plastic 
parts. Avoid using chemicals.
  Even if you have to use chemicals to clean heavy dirt, don’t use paint 
thinner, ketone, nor alcohol.
•   Insert the specific screws vertically to the part when installing a plastic 
part.
  Be careful not to tighten screws too much.
各種薬品の取り扱いについて
現在使用されている薬品の中には揮発性の高い薬品もありま
す。
それらを不用意に取り扱い蒸発させてしまうと,環境や健康へ
影響を与えたり,資源の無駄使いになります。
各種薬品は,下記の点に注意して取り扱ってください。
・  保管場所を定め,高温になったり直射日光の当たらない場所
に密閉して保管してください。
・  小分け(ハンドラップ等)する数は必要最小限に留め,容器に
よる自然蒸発を防いでください。
・  作業に使用しない時は,必ずキャップ等をして自然蒸発を防
いでください。
・  薬品を使用する回数を極力少なくし,使用する場合は使用す
る量だけ容器より出して受け皿に残さないようにしてくださ
い。
樹脂系部品の取り扱いについて
本機に使用されている樹脂系の部品は,下記の点に注意して取
り扱ってください。
・  清掃には薬品を使用せず,清掃紙や清掃布を使用してくださ
い。
  やむを得ず汚れがひどくて薬品を使用する場合は,シンナー,
ケトン,エーテルは使用しないでください。
・  各部品の取り付けには指定されたねじを使用し,部品に対し
て垂直に取り付けてください。
  また,ねじを締め付ける時は,無理な力を加えないでくださ
い。
注意
如果电池更换不当会有爆炸危险。
只能用同样类型或等效类型的电池来更换。
务必按照说明处置用完的电池。
1-1
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
1. SERVICE  NOTE
1-1.  POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4 Vdc), the power is shut off 
so that the unit cannot operate.
These following method is available to prevent this.
Method:
Use the AC power adaptor.
1-2.  PRECAUTION ON REPLACING THE VC-650 BOARD
Note the following when replacing the board.
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
USB Serial No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
Identification of VC board
There are two types of repair VC board. When replacing this board, check the identification mark by marker pen.
No identification mark:  FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700U/FS700UK
Identification mark: 
FS700R/FS700RH
Identification mark
VC-650 BOARD (SIDE B)
– ENGLISH –
1-3.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
 
Destination Ver. window
3)  Search the model whose new Destination Data file you want to get on the TISS homepage.
 
When the Destination Data file has been updated, a file with a name “Destination File For ‘model name’.zip” is registered.
(Example) Destination File For 
DSC-WX50
.zip
Furthermore, the version supported by the Destination Data file is shown in the Remarks column.
Note : If the Destination Data file has not been updated, contact the Service Headquarters.
1-2
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
– ENGLISH –
 4)  Download the Destination Data file of the relevant model and unzip the file.
 
5)  Execute “DESTINATION DATA WRITE” in the Adjust tab of the Adjust manual.
 
Click the [START] button.
 
6)  Click the [File Update] button in the window.
 
7)  A file selection screen opens. Select the Destination Data file to be added and click the [Open] button.
 
8)  When the file has been successfully added, the following window opens.
 
9)  Check the Destination Ver. window and confirm that the version has been updated.
 
Destination Ver. window
1-3
NEX-FS700/FS700K/FS700C/FS700CK/FS700E/FS700EK/FS700J/FS700JK/FS700R/FS700RH/FS700U/FS700UK
– ENGLISH –
1-4.  PRECAUTION ON REPLACING THE MB N PLATE AND NDF UNIT
Perform the following procedures for each of the three washers.
Note: Measure the dimensions before replacement of the MB N Plate and NDF Unit according to procedures (1) to (3).
(1) Remove the Imager Block Assy and the IM Adjust Washers (A).
(2) Measure the dimensions (A) of the removed IM Adjust Washers.
SSM height adjustment
measurement JIG
-$
A
+
B
BA
(3) Measure the distance (B) between the surface of the screw hole where the IM Adjust Washers were set and the surface of the E-Mount.
(4) Likewise, measure the dimensions (B’) of each location where IM Adjust Washers of new Cabinet Front are installed.
(5) Calculate the dimension of (A’) of new IM Adjust Washer by using the formula below, and select the washers.
  
Dimension 
(A+B) before replacement – Dimension (B’) of new Cabinet Front
           
= Dimension (A’) of IM Adjust Washer after replacement
(6) Assemble the imager, using the selected IM Adjust Washers.
(7) After assembling is completed, perform the test shooting and confirm that no blur is observed in the peripheral area of shot.
1-5. SELF-DIAGNOSIS FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service 
mode display. Details of the self-diagnosis functions are provided in the 
Instruction manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD 
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the “repaired 
by:”, “block” in which the problem occurred, and “detailed code”of the 
problem.
0 0
3 2
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
E : Corrected by service
engineer
LCD screen
C : Corrected by customer
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Access error
Remove the power source. Reconnect it again and operate your cam-
corder again.
C
1
3
0
3
Access error (External media)
Turn power off and turn power on again.
C
1
3
0
4
Drive fault (External media)
Turn power off and turn power on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “DESTINATION DATA WRITE”.
Note 2: Functions of codes with * mark are not provided in this unit.
(                                            )
*
*
Page of 112
Display

Click on the first or last page to see other NEX-FS700 / NEX-FS700C / NEX-FS700CK / NEX-FS700E / NEX-FS700EK / NEX-FS700J / NEX-FS700JK / NEX-FS700K / NEX-FS700R / NEX-FS700RH / NEX-FS700U / NEX-FS700UK service manuals if exist.