ILCE-7/7K/7R_L2
– 3 –
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH 
MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST 
ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPO-
NENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS 
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY 
SONY. 
ATTENTION AU  COMPOSANT  AYANT  RAPPORT 
À  LA  SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES 
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT 
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REM-
PLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT 
LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES 
SUPPLÉMENTS PUBLIÉS PAR SONY.
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
Caution
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
CHEMICALS
Some chemicals used for servicing are highly volatile.
Their evaporation caused by improper management affects your health 
and environment, and wastes resources.
Manage the chemicals carefully as follows.
•  Store chemicals sealed in a specific place to prevent from exposure 
to high temperature or direct sunlight.
•  Avoid dividing chemicals into excessive numbers of small containers 
to reduce natural evaporation.
•  Keep containers sealed to avoid natural evaporation when chemicals 
are not in use.
•  Avoid using chemicals as much as possible. When using chemicals, 
divide only required amount to a small plate from the container and 
use up it.
EXTERIOR  PARTS
Be careful to the following points for plastic parts used in this unit.
•  Use a piece of cleaning paper or cleaning cloth for cleaning plastic 
parts. Avoid using chemicals.
 
Even if you have to use chemicals to clean heavy dirt, don’t use paint 
thinner, ketone, nor alcohol.
•  Insert the specific screws vertically to the part when installing a 
plastic part.
 
Be careful not to tighten screws too much.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer.
各種薬品の取り扱いについて
現在使用されている薬品の中には揮発性の高い薬品もありま
す。
それらを不用意に取り扱い蒸発させてしまうと,環境や健康へ
影響を与えたり,資源の無駄使いになります。
各種薬品は,下記の点に注意して取り扱ってください。
・ 
保管場所を定め,高温になったり直射日光の当たらない場
所に密閉して保管してください。
・ 
小分け(ハンドラップ等)する数は必要最小限に留め,容器
による自然蒸発を防いでください。
・ 
作業に使用しない時は,必ずキャップ等をして自然蒸発を
防いでください。
・ 
薬品を使用する回数を極力少なくし,使用する場合は使用
する量だけ容器より出して受け皿に残さないようにしてく
ださい。
樹脂系部品の取り扱いについて
本機に使用されている樹脂系の部品は,下記の点に注意して取
り扱ってください。
・ 
清掃には薬品を使用せず,清掃紙や清掃布を使用してくだ
さい。
 
やむを得ず汚れがひどくて薬品を使用する場合は,シン
ナー,ケトン,エーテルは使用しないでください。
・ 
各部品の取り付けには指定されたねじを使用し,部品に対
して垂直に取り付けてください。
 
また,ねじを締め付ける時は,無理な力を加えないでくだ
さい。
サービス,点検時には次のことにご注意ください。
– ENGLISH –
– JAPANESE –
1.  Check the area of your repair for unsoldered or poorly-soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or contact high-wattage resistors.
3.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
4.  Look for parts which, through functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
5.  Check the B+ voltage to see it is at the values specified.
6.  Flexible Circuit Board Repairing
 
•   Keep the temperature of the soldering iron around 350°C during 
repairing.
 
•   Do not touch the soldering iron on the same conductor of the circuit 
board (within 3 times).
 
•   Be careful not to apply force on the conductor when soldering or 
unsoldering.
UNLEADED  SOLDER
This unit uses unleaded solder. 
Boards requiring use of unleaded solder are printed with the lead free 
mark (LF) indicating the solder contains no lead.
(Caution:  Some printed circuit boards may not come printed with the 
lead free mark due to their particular size.)
: LEAD FREE MARK
Be careful to the following points to solder or unsolder.
•  Set the soldering iron tip temperature to 350°C approximately.
 
If cannot control temperature, solder/unsolder at high temperature 
for a short time.
 
Caution: The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!
 
 
Unleaded solder is more viscous (sticky, less prone to 
flow) than ordinary solder so use caution not to let solder 
bridges occur such as on IC pins, etc.
•  Be sure to control soldering iron tips used for unleaded solder and 
those for leaded solder so they are managed separately. Mixing 
unleaded solder and leaded solder will cause detachment phenom-
enon.
1.  注意事項をお守りください。
 
サービスのとき特に注意を要する個所については,キャビ
ネット,シャーシ,部品などにラベルや捺印で注意事項を
表示しています。これらの注意書きおよび取扱説明書等の
注意事項を必ずお守りください。
2.  指定部品のご使用を
 
セットの部品は難燃性や耐電圧など安全上の特性を持った
ものとなっています。従って交換部品は,使用されていた
ものと同じ特性の部品を使用してください。特に回路図,
部品表に0印で指定されている安全上重要な部品は必ず指
定のものをご使用ください。
3.  部品の取付けや配線の引きまわしはもとどおりに
 
安全上,チューブやテープなどの絶縁材料を使用したり,
プリント基板から浮かして取付けた部品があります。また
内部配線は引きまわしやクランパによって発熱部品や高圧
部品に接近しないよう配慮されていますので,これらは必
ずもとどおりにしてください。
4.  サービス後は安全点検を
 
サービスのために取外したネジ,部品,配線がもとどおり
になっているか,またサービスした個所の周辺を劣化させ
てしまったところがないかなどを点検し,安全性が確保さ
れていることを確認してください。
5.  チップ部品交換時の注意
 
・  取外した部品は再使用しないでください。
 
・  タンタルコンデンサのマイナス側は熱に弱いため交換時
は注意してください。
6.  フレキシブルプリント基板の取扱いについて
 
・  こて先温度を約350℃に設定して行ってください。
 
・  同一パターンに何度もこて先を当てないでください。
 
  (3回以内)
 
・  パターンに力が加わらないよう注意してください。
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(Lead Free)を意味する
レッドフリーマークがプリントされています。
(注意: 基板サイズによっては,無鉛半田を使用していてもレッ
ドフリーマークがプリントされていないものがありま
す)
:レッドフリーマーク
無鉛半田は,下記の点に注意して使用してください。
・ 
半田こてのこて先温度は約350℃に設定してください。
 
温度調節が無理な場合は,高温短時間で作業を行ってくだ
さい。
 
注意: 半田こてを長く当てすぎると,基板のパターン(銅
箔)がはがれてしまうことがありますので,注意して
ください。また,従来の半田よりも粘性が強いため,
IC端子などが半田ブリッジしないように注意してく
ださい。
・ 
半田こてのこて先は,必ず無鉛半田用と有鉛半田用に分け
て管理してください。
 
無鉛半田と有鉛半田が混在すると剥離現象が発生してしま
います。
注意
如果电池更换不当会有爆炸危险。
只能用同样类型或等效类型的电池来更换。
务必按照说明处置用完的电池。
ILCE-7/7K/7R_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-1022 BOARD
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
Deleting Network Settings
Before replacing the SY-1022 board, delete the customer’s network settings.
Start the Adjust Manual in the Adjust Station and execute the “NETWORK SETTING RESET”.
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note:  A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Imager DRA Data
Extract the imager data from the set before the SY board replacement using “Restore Data (Imager DRA Data Reference)” in the DATA tab of the 
Adjust manual. 
After the SY board has been replaced, write the data extracted from the set before the SY board replacement in the set using “Imager DRA Data Write” 
in the ADJUST tab of the Adjust manual.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC ad-
dress) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
1.  Download the latest-version Adjust Manual.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN check” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize.
 MENU 
→ 
 → [Reset Network Settings] → [OK] → ●
5.  Perform the following operations for the unit to display MAC address.
 MENU 
→ 
 → [Disp MAC Address] → ●
6.  Confirm that the displayed MAC address has been updated.
Applicable parts
•  SY-1022 BOARD, COMPLETE (SERVICE)
Note: The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
Perform the above operations after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, print out the 
flyer given at the manual and attach it to the set when returning the set to customer.
1-2.  PRECAUTION FOR REPLACEMENT OF IMAGER (ILCE-7/7K)
In this model, the following procedure is required when the imager is replaced.
•  In the case that the imager data can be extracted from the set before the replacement, refer to “Imager DRA Data” in “1-1. PRECAUTION ON 
REPLACING THE SY-1022 BOARD”.
•  In the case that the imager data cannot be extracted from the set before the replacement, replace both SY board and imager unit. 
  Capture the data to PC from CD-ROM supplied with the imager unit when it is ordered.
  Write the captured data in the set using “Imager DRA Data Write” in the ADJUST tab of the Adjust manual.
  After all adjustment items have been completed, execute “Phase Difference AF Check” on the SERVICE tab of the Adjust manual.
– ENGLISH –
1-3.  NOTES FOR REPLACING THE EVF DISPLAY DEVICE (LCD902) OR THE SY-1022 BOARD
WB adjustment values of each EVF display device (LCD902) are stored on the SY board.
Therefore, when the LCD902 or the SY board has been replaced, write WB adjustment values.
10/11_193_26_0
Adjustment
value
The label which is put on repairing EVF display device (LCD902)
When LCD902 is replaced:
1.  Check and write down the adjustment values printed on the repairing EVF display device (LCD902) label.
2.  After the LCD902 has been replaced, execute “EVF Data Input” on the ADJUST tab by using the Adjust manual to write the adjustment values.
When replacing SY board (in case adjustment values can be read):
1.  In case the unrepaired unit starts and adjustment values can be read by using the Adjust manual, execute “ADJUSTMENT DATA BACKUP” on 
the DATA tab.
2.   After the SY board has been replaced with a SY board for repair, execute “ADJUSTMENT DATA BACKUP” on the DATA tab of the Adjust 
manual to write the extracted data to the unit.
When replacing SY board (in case adjustment values cannot be read):
Consult with each Head Quarters.
ILCE-7/7K/7R_L2
1-2
1-4.  CHECKING THE Wi-Fi FUNCTION
Perform the following procedure to check the Wi-Fi function.
Required equipment: Windows personal computer with Wi-Fi interface
1.  Turn on the power of the unit.
2.  Perform the following operations for the unit.
 MENU→ 
 →[Send to Smartphone]→●
3.  The Send to smartphone screen is displayed.
4.  The image selected from the camera or smartphone is displayed, select the picture to be used.
5.  Select “This image” on the view on smartphone screen and press the ● of the center, the “Wi-Fi Standby…” screen is appeared.
6.  When preparation for Wi-Fi has been completed, the “Running as an access point.” screen opens and a password for Wi-Fi connection is displayed.
SSID
 
DIRECT-XXXX:MODEL-NAME
Password
  
XXXXXXXX
Device Name
  
ILCE-XX
Wi-Fi
Send to Smartphone
Operate smartphone to connect to 
this device via Wi-Fi.
Cancel
Enter
7.  Confirm on the personal computer that the unit is detected as a connectable wireless network.
8.  To further confirm that the unit is connectable, connect the unit to the personal computer and select “Network and Internet” → “Manage Wireless 
Networks” from Control Panel to open the network connection list. The unit is included in the list.
– ENGLISH –
– JAPANESE –
1-1.  SY-1022基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
ネットワーク設定の消去
SY-1022基板を交換する際は,基板を交換する前にお客様のネットワーク設定を消去してください。
Adjust StationからAdjust Manualを起動させて 「NETWORK SETTING RESET」を実行させてください。
USBシリアルNo.およびプロダクトIDについて
本機はセット固有のID(USBシリアルNo.)と機種固有のID(プロダクトID)を書き込んだ後に出荷されています。
新品の補修用基板にはこれらのIDが書き込まれていないため,基板交換後にIDを入力する必要があります。
補修用基板に交換した後はAdjust StationからAdjust Manualを起動し,「PRODUCT ID & USB SERIAL No. INPUT」を実行させてIDを入
力してください。
Note:  新しくプロダクトIDを入力すると,必ずしも基板交換前のIDと同じIDになるとは限りません。新しいIDと元のIDが違う場合にはお客様がユーザー登録さ
れているIDと相違が出てしまう可能性があります。
イメージャ DRA データ
Adjust manualのDATAタブにある,
「Restore Data (Imager DRA Data Reference)」を使用して,SY基板を交換する前のセットからイメー
ジャデータを抽出してください。
SY基板の交換後,Adjust manualのADJUSTタブにある,「Imager DRA Data Write」を使用してSY基板を交換する前のセットから抽出
したデータをセットへ書き込んでください。
MAC アドレスの更新
Wi-Fi 搭載基板を交換した時,またはメイン IC (CPU) が搭載されている基板を交換した場合,IC の固有番号 (MAC アドレス) を取り
込み直す必要があります。
下記の作業を実施して,IC の固有番号 (MAC アドレス) を取り込み直してください。
1.  最新版のAdjust Manualをダウンロードする。
2.  ダウンロードしたAdjust Manualをインストールする。
3.  Adjust Manualを起動し,ADJUSTタブにある「Wireless LAN check」を実施する。
4.  セット本体を下記のように操作し,設定リセットを行う。
 
MENU → 
 → [ネットワーク設定リセット] →[確認] → 中央の●で決定
5.  セット本体を下記のように操作し,MACアドレスを表示する。
 
MENU → 
 → [MACアドレス表示] → 中央の●で決定
6.  MACアドレスの表示が更新されていることを確認する。
対象となる部品
・  SY-1022 BOARD, COMPLETE (SERVICE)
Note:  
 Adjust manual 内の DATA タブにある,ADJUSTMENT DATA BACKUP にある機能,LOAD AND WRITE は,セットの全てのデータを上書き
します。
 
 
そのため,上記の操作で更新した MAC アドレス も上書きされてしまいます。
上記の操作は全ての作業を実施した後に行ってください。
交換修理後はMAC アドレスが変更されていますので,お客様に接続機器の再設定をしていただく必要があります。そのため巻末
の投げ込みをプリント出力し,セットに添付して返却してください。
1-2. イメージャ交換時の注意 (ILCE-7/7K)
このモデルではイメージャを交換する際に,下記の手順が必要です。
・  交換前のセットからイメージャデータの抽出が可能である場合
  "1-1. SY-1022基板交換時の注意" にある "イメージャ DRA データ" の内容を参照してください。
・  交換前のセットからデータの抽出が不可能である場合
  SY基板とイメージャユニットの両方を交換してください。
  また,イメージャユニットを注文した際に添付されているCD-ROMよりデータをPCに取り込んでください。
  取り込んだデータを Adjust manual のADJUSTタブにある,「Imager DRA Data Write」を使用してセットへ書き込んでください。
  また調整の全項目が完了した後に,Adjust manual の SERVICE タブにある「Phase Difference AF Check」を実施してください。
ILCE-7/7K/7R_L2
1-3E
– JAPANESE –
1-3.   EVF表示素子(LCD902)またはSY-1022基板交換時の注意
本機ではEVF表示素子(LCD902)ごとのWB調整値がSY基板に書き込まれています。
このためLCD902またはSY基板を交換した場合には調整値の書き込みを行ってください。
10/11_193_26_0
調整値
補修用EVF素子(LCD902)に貼られているラベル
LCD902交換時
1.  補修用EVF素子(LCD902)のラベルに印字されている調整値を確認し,控えておく。
2.  交換作業が完了したらAdjust manualを使用し,ADJUSTタブにある「EVF Data Input」を実行する。
SY基板交換時 (調整値を読み取り可能な場合)
1.  修理前のセットが起動し,Adjust manualを使用し調整値を読み取ることが可能な場合は,DATAタブにある「ADJUSTMENT 
DATA BACKUP」を実行する。
2.  補修用SY基板に交換した後,抽出したデータをAdjust manualのDATAタブにある「ADJUSTMENT DATA BACKUP」を実行してセッ
トに書き込む。
SY基板交換時 (調整値を読み取り不可能な場合)
サービスHQへお問い合わせください。
1-4.  Wi-Fi機能の確認
Wi-Fi 機能を確認するときは以下の手順で行ってください。
用意する機器: Wi-Fi接続の可能なWindowsパソコン
1.  本機の電源を入れる。
2.  セット本体を下記のように操作する。
 
MENU→ 
 →[スマートフォン転送]→中央の●で決定
3.  スマートフォン転送画面が表示される。
4.  カメラまたはスマートフォンから画像を選択する画面が表示されるので,使用したい画像が保存されている方を選択する。
5.  スマートフォン転送画面から「この画像」を選択し、中央の●を押すと「Wi-Fi準備中」の画面に切り替わる。
6.  Wi-Fi準備が完了すると「アクセスポイントとして動作中」という画面に切り替わり,Wi-Fi接続のためのパスワードが表示される。
スマートフォン転送
スマートフォンを操作して
本機にWi-Fi接続してください
SSID
 
DIRECT-XXXX:MODEL-NAME
パスワード
 
XXXXXXXX
機器名称
  
ILCE-XX
Wi-Fi
キャンセル
● 決定
7.  パソコン側で接続可能なワイヤレスネットワークとして,本機が検出されることを確認する。
8.  さらに接続可能なことを確認したい場合には本機とパソコンを接続後,コントロールパネルの「ネットワークとインターネット」 
→ 「ワイヤレスネットワークの管理」からネットワーク接続リストを開くと,リストに本機が表示される。
Page of 24
Display

Sony ILCE-7 / ILCE-7K / ILCE-7R (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony ILCE-7 / ILCE-7K / ILCE-7R (serv.man2) Service Manual ↓ Size: 9.02 MB | Pages: 24 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony ILCE-7 / ILCE-7K / ILCE-7R (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony ILCE-7 / ILCE-7K / ILCE-7R (serv.man2) Digital Camera. Information contained in Sony ILCE-7 / ILCE-7K / ILCE-7R (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.