Digital Camera / SECTION 6 ADJUSTMENTS
File
dslr-a100-dslr-a100h-dslr-a100k-dslr-a100w-sm3.pdf
Date

Sony DSLR-A100 / DSLR-A100H / DSLR-A100K / DSLR-A100W (serv.man3) Service Manual ▷ View online

6-34
DSLR-A100_ADJ
21.
Sensitivity adjustment (CCD GAIN)
Required equipment
Luminance box
AE master lens
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Set the camera and the measuring instrument as shown on the Fig. 1.
3. Set the brightness of the Luminance box to EV 7.
4. Click “CCD GAIN” of the adjustment menu.
 “Does it adjust?” appears.
5. Click “YES”  then automatic adjustment starts.
6. The adjustment is completed when “OK” is displayed on the adjustment menu.
22.
Adjustment of the defective pixel (DEFECT PIXEL)
Required equipment
Luminance box
AE master lens
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Set the camera and the measuring instrument as shown on the Fig.1.
3. Set the brightness of the Luminance box to EV 8.
4. Click “DEFECT PIXEL” of the adjustment menu.
“Does it adjust?” appears.
5. Click “YES”  then automatic adjustment starts.
6. The adjustment is completed when “OK” is displayed on the adjustment menu.
Fig. 1
Fig. 1
Luminance box
During the adjustment, cover the 
luminance surface and body with 
a blackout curtain, etc. for shielding.
Luminance box
6-35
DSLR-A100_ADJ
Fig. 1
955 
±
 2 mm
Back ground paper
The chart must appear on the entire picture frame.
Lens mount surface
23.
Built-in Flash Adjustment (BI FLASH)
Adjust the dispersion of photometric device to the built-in flash.
This adjustment should be performed in a dark room.
Required equipment
Back ground paper (Size: 30 cm x 42 cm or larger)
PC with preinstalled the DSLR-A100 adjustment program
AE master lens
USB cable
AC adaptor/charger (AC-VQ900AM)
Distance when adjusting
Lens mount surface to Back ground paper = 955 
± 2 mm
Procedure of the adjustment
1. Pop up the flash lamp of the camera, and set the camera and chart as shown in Fig. 1.
2. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
3. Click “BI FLASH” of the adjustment menu.
4. “Does it adjust?” appears. Click “YES”.
5. Repeating the flash of flash lamp, automatic adjustment is taken place. (The lamp will flash about 15 times.)
6. “BI FLASH adjustment has completed!” appears when adjustment is completed.
6-36
DSLR-A100_ADJ
24.
Adjustment of white balance (WB)
Required equipment
Light Source-A (Refer to Light source-A maintenance.)
Light balance filter LB200
Master body
AE master lens
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
All white chart
Procedure of the adjustment
1. Set Master body to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Set the camera and the measuring instrument as shown on the Fig.1.
3. Click “WB” of the adjustment menu.
4. Click “MASTER” of WB adjustment menu.
5. Click “OK” after setting light source-A, according to the displayed information.
The adjustment is automatically started.
6. Click “OK” after setting light source-C, according to the displayed information. (Fig. 2)
The adjustment is automatically started.
7. “OK” is displayed on the adjustment menu, then reading data is complete.
8. Click “ADJUSTMENT END”
9. Exchange Master camera for target camera.
Be careful to exchange camera to avoid any change to the setting.
10. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
11. Click “WB” of the adjustment menu.
12. Click “ADJUSTMENT” of WB Adjustment menu.
13. “Does it adjust?” is displayed in the window, then click “YES”.
14. Click “OK” after setting light source-A, according to the displayed information.
The adjustment is automatically started.
15. Click “OK” after setting light source C, according to the displayed information. (Fig. 2)
The adjustment is automatically started.
16. The adjustment is completed when “OK” is displayed on the adjustment menu.
Fig. 1
Fig. 2
AE master lens
Light Source-A
Refer to Light source-A maintenance
All white chart
The chart must appear on the entire picture frame.
Light balance filter LB200
6-37
DSLR-A100_ADJ
Fig. 1
CAMERA
Exposure mode: M
Focus mode: MF
LENS
Master Lens for Shake
Frequency of 60 Hz: 300 
±
 5 r/min
Frequency of 50 Hz: 250 
±
 5 r/min
Control
Lens mount surface
1555 
±
 2 mm
Shake Offset Chart 
II
25.
Adjustment of the camera shaking compensation (SHAKE GAIN)
Required equipment
Vibration tester
Shake offset chart II
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Master lens for shake
Preparation of the adjustment
1. Set the camera without USB cable and the measuring instrument as shown on the Fig. 1.
Set distance between camera and shake offset chart II to 1555 
± 2 mm
      
Note 1:
Distance between camera and chart means distance between lens mount surface of the camera and chart. About lens mount
surface, refer to Fig. 1.
Note 2:
Use indirect lighting like room light for the lighting of the chart, not to use other direct lighting. If direct lighting is used,
adjustment error often happens because of the mis-detecting of the cross line of the chart.
2. Set the center of the camera finder to the center of the chart.
3. Confirm whether the center of the chart is located at the center of the screen or not by setting the camera to after view mode. If the
center of the chart is not located at the center of the screen, please perform setting again.
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
Attach the master lens for shake to the camera, and then set to the adjustment mode.
Confirm that the aperture value is not indicated as “--” on the LCD of the camera.
2. Click “SHAKE GAIN” of the adjustment menu. “Does it adjust?” appears.
3. Click “YES”  then take a picture in the automatic mode.
4. Follow the message, “Please turn on shake!”  Turn the power of the vibration tester on, and click “OK” after setting the rotation as
follows (Fig.1).  8 or 4 pictures are automatically taken.
Frequency of 60 Hz: 300 
± 5 r/min
Frequency of 50 Hz: 250 
± 5 r/min
5. Follow the message, “Please turn off shake!”  Turn the power of the vibration tester off, and click “OK” .
6. The adjustment is completed when “OK” is displayed on the adjustment menu.