DOWNLOAD Sony DSC-W580 (serv.man2) Service Manual ↓ Size: 7.1 MB | Pages: 21 in PDF or view online for FREE

Model
DSC-W580 (serv.man2)
Pages
21
Size
7.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-w580-sm2.pdf
Date

Sony DSC-W580 (serv.man2) Service Manual ▷ View online

DSC-W580_L2
1-3
– ENGLISH –
1-6.  PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed 
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
Method for Initializing the Flash Error Code
Initialize 
Initializes the setting to the default setting.  
Even if you execute this function, the images are retained. 
1. MENU 
 
 (Settings) 
 
 (Main Settings) 
 [Initialize] 
 [OK] 
 
Note 
Be sure not to turn off the camera while initializing. 
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a me-
dia error.
Turn the power off and on again.
The internal memory has experienced a for-
mat error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the 
memory card.
Turn the power off and on again, or taking out and inserting the memory 
card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, 
check the focus reset sensor of lens block (pin wk of CN401 on the 
SY-274 board). If it is OK, check the focus motor drive IC (IC401 on 
the SY-274 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset 
sensor of lens block (pin eg of CN401 on the SY-274 board) when 
zooming is performed when the zoom button is operated. If it is OK, 
check the zoom motor drive IC (IC401 on the SY-274 board).
E
6
2
0
2
Abnormality of IC for steadyshot.
Check of the IC for steadyshot (IC401 on the SY-274 board).
E
6
2
1
0
Lens initializing failure.
Check of the IC for steadyshot (IC401 on the SY-274 board).
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin wa of 
CN401 on the SY-274 board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin qf, 
qh
 of CN401 on the SY-274 board). If it is OK, check PITCH angular 
velocity sensor (SE401 on the SY-274 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin qd, 
qa
 of CN401 on the SY-274 board). If it is OK, check YAW angular 
velocity sensor (SE401 on the SY-274 board) peripheral circuits.
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note)
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC201 on the SY-274 board).
Note: After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2011.07
DSC-W580_L2
1-4
1-7.  ORNAMENTAL RING A OR BARRIER ASSY REPLACING METHOD
1-8.  OPTICAL STEPPING MOTOR (F1430) REPLACING METHOD
A
Barrier Assy
Claws
Claws
Hole
Barrier Assy
Claws
Claws
Barrier
Lever
3
4
Installation
1
2
5
Removal
1
2
3
4
Barrier Tape
Dent
Ornamental Ring A
Barrier Assy
Barrier Tapes
Barrier Tape
Barrier Tape
Ornamental Ring A
Solvent
Tweezers
Disengage the four claws and remove the Barrier Assy.
Fit the four claws while inserting the Barrier Lever into the hole and attach the Barrier Assy.
Affix two Barrier Tapes to the Barrier Assy so that the end of each Barrier Tape touches the dent.
Note: The Barrier Tapes must not be wrinkled.
Peel off the release papers of the Barrier Tapes.
Install the Ornamental Ring A and press it lightly.
Turn on the power switch and extend the lens (WIDE end).
Detach the battery.
Apply alcohol to two gaps A of the Ornamental Ring A with tweezers or a fine-tipped stick as shown below.
Turn the Ornamental Ring A clockwise and counterclockwise to detach it.
Removal
1
2
Screw
Optical Stepping
Motor (F1430)
Solders
Install
1
2
Screw
Optical Stepping
Motor (F1430)
Groove
Projection
of worm
Solders
Remove the screw.
Unsolder the four locations of the Optical Stepping Motor (F1430) to detach it.
Solder the four locations of the Optical Stepping Motor (F1430).
Install the Optical Stepping Motor (F1430) with a screw.
*Tightening torque = 0.0xx
± 0.0xN • m (0.x ± 0.xkgf • cm)
Note:
Install the Optical Stepping Motor (F1430) while fitting the groove with the projection of worm.
DSC-W580_L2
1-5
1-9.  DC MOTOR WORM (A) BLOCK ASSY REPLACING METHOD
5
6
7
Removal
1
2
3
4
Remove the Rear Mirror Plate.
Remove the Gear B (Black) and the Gear A (White).
Remove the two screws, and remove soldering from the two points, and then remove the DC Motor (A) Block Assy.
Claws
Screws
Screws
Rear Mirror
Plate
DC Motor Worm
(A) Block Assy
Solders
Screws
Gear B
(Black)
Gear A
(White)
Sensor
Sensor
Claw
Boss
Rib
Rib
Claw
Disconnect the Iris Flexible Board
from LF-115 Flexible Board.
Top View
FG Leaf
Spring
Boss
Claws
FPC Retainer
Back View
Rib
LF-115 Flexible Board
Disengage the two claws and remove the FG Leaf Spring.
Remove the two Sensors.
Disengage the three claws and remove the FPC Retainer.
Remove the LF-115 Flexible Board.
Installation
1
2
3
4
Solder the two locations.
Install the DC Motor Worm (A) Block Assy and secure it with two screws.
*Tightening torque = 0.0xx
± 0.0xN • m (0.x ± 0.xkgf • cm)
Install the Gear B (Black) and the Gear A (White).
Install the Rear Mirror Plate and secure it with two screws.
*Tightening torque = 0.0xx
± 0.0xN • m (0.x ± 0.xkgf • cm)
Install the LF-115 Flexible Board.
Install the FPC Retainer while fitting the three claws and the boss.
Install the two Sensors
Install the FG Leaf Spring while fitting the two claws..
6
7
8
Claws
Sensor
Sensor
FG Leaf Spring
Boss
FPC Retainer
Claw
Boss
Rib
Rib
Claw
Disconnect the Iris Flexible Board
from LF-115 Flexible Board.
Top View
Back View
5
Screws
Screws
Rear Mirror Plate
DC Motor Worm
(A) Block Assy
Solders
Screws
Gear B
(Black)
Gear B
(Black)
Gear D
(Black)
Naruto
Gear
Gear A
(White)
Gear A
(White)
Gear C
(White)
Claws
Rib
LF-115 Flexible Board
DSC-W580_L2
1-6
5
6
Removal
1
2
3
4
Claws
Sensor
Sensor
Claw
Boss
Rib
Rib
Rib
Claw
Disconnect the Iris Flexible Board
from LF-115 Flexible Board.
LF-115 Flexible Board
Top View
FG Leaf
Spring
Boss
Claws
FPC Retainer
Back View
Gear B
(Black)
Gear D
(Black)
Gear A
(White)
Gear C
(White)
Naruto
Gear
Screws
Rear Mirror
Plate
Screws
Disengage the two claws and remove the FG Leaf Spring.
Remove the two Sensors.
Disengage the three claws and remove the FPC Retainer.
Remove the LF-115 Flexible Board.
Remove the four screws to detach the Rear Mirror Plate
Remove the Gear B (Black), Gear A (White), Gear C (White), Gear D (Black), and Naruto Gear.
7
8
9
Iris Flexible Board
Cutout
Main Assy (A)
Rotary Tube
Block Assy
3 Group Spring
3 Group Frame
Block Assy
Tube
Lubricating
q;
qa
Main Assy (B)
Tube Lubricating
Block Assy
Shield Ring (C)
Remove the 3 Group spring and remove the 3 Group Frame Block Assy..
Turn the Tube Lubricating to the TELE state and remove the Iris Flexible Board from the cutout.
Remove the Main Assy (A) in the WIDE state.
Remove the Main Assy (B).
Remove the Tube Lubricating Block Assy and the Shield Ring (C) from the Rotary Tube Block Assy.
1-10.   TWO TUBE LUBRICATING BLOCK ASSY AND GROUP 1 FRAME REPLACING METHOD
Page of 21
Display