DOWNLOAD Sony DSC-W30 (serv.man3) Service Manual ↓ Size: 493.33 KB | Pages: 32 in PDF or view online for FREE

Model
DSC-W30 (serv.man3)
Pages
32
Size
493.33 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS BRAZIL
File
dsc-w30-sm3.pdf
Date

Sony DSC-W30 (serv.man3) Service Manual ▷ View online

6-23
DSC-W30_ADJ
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj. ”.
3) Upon successful completion of the “1. Data setting during LCD
Adj. & EVR Data Write”, the following message is displayed
during execution in “2. V-COM Adj. ”. On the SEUS screen,
operate the UP/DOWN key so that the brightness of portions
A and B on the LCD panel is equal. After the adjustment, click
the 
[OK]
 button.
Fig. 6-1-46
4) Upon completion of “2. V-COM Adj.”, “3. White Balance Adj.”
is executed. The following message is displayed, and then check
that LCD screen is not colored.
If colored, change the data of page: 8F, address: 42 and 43 on
the SEUS Operation screen to adjust so that the LCD screen is
not colored.
Fig. 6-1-47
5) If the 
[OK]
 button is clicked, “4. Release of Data Setting dur-
ing LCD Adj.” will be executed.
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the 
[OK]
 button.
Fig. 6-1-48
SEUS operation screen
Fig. 6-1-49
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-50
UP/DOWN key
A
B
6-24
DSC-W30_ADJ
1-6. ERRO
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-6-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error
Fig. 6-1-51
Symptom
USB communication with the set is abnormal.
Cause
USB cable is not inserted tightly.
Power supply is not installed correctly.
Communication with SEUS is abnormal.
Remedy
Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
Install the power supply correctly.
Start the SEUS and click the 
[Connect]
 to
check that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-52
Symptom
The camera is not ready for adjustment.
Cause
Data error exists in the camera.
Remedy
Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-53
Symptom
Adjustment does not finish within the specified
time.
Cause
Adjustment conditions are wrong.
Data error exists in the camera.
Remedy
Check that the conditions such as a subject
are correct.
Reset the camera.
4.
Adjustment NG
Fig. 6-1-54
Symptom
The adjusted data does not become the speci-
fied value.
Cause
Adjustment conditions are wrong.
Data error exists in the camera.
Remedy
Check that the conditions such as a subject
are correct.
Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-25
DSC-W30_ADJ
5.
Data Save Error
Fig. 6-1-55
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
Data writing to the flash memory failed.
Connection is faulty.
Power supply is not installed correctly.
Remedy
On the SEUS Operation screen, 
[Set]
 the data
to the pages and addresses displayed in the
message, and 
[Save]
 them. (Cancel manu-
ally the data setting during adjustment.)
Check the connection.
Install the power supply correctly.
1-6-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not op-
erate normally.
In this case, the 
[Release  Data  Setting]
 button is displayed in
“red” on the screen as shown in Fig. 6-1-56, 57 and 58. Click the
[Release Data Setting]
 button to cancel the data setting. When
the data setting is cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred,  the 
[Release Data
Setting]
 button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Video System Adjustment screen
Fig. 6-1-56
Camera System Adjustment screen
Fig. 6-1-57
LCD System Adjustment screen
Fig. 6-1-58
How to cancel the 
data setting during 
adjustment is 
display here.
6-26
DSC-W30_ADJ
1-7. INICIAÇÃO DOS DADOS
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “03”.
4) Click 
[All]
 of the ALL SELECT buttons to select all pages.
(Fig. 6-1-59 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is “00”.
10) Select page: 80, address: 30, and check that the data is “00”.
11) Perform“VIDEO OUT Default Data and Exif Model Data
Check” and “Initial Language Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
Fig. 6-1-59
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6D or 6E or 6F or 78 page data have been initial-
ized, the following adjustment needs to be performed
again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “03”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-59
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is “00”.
10) Select page: 80, address: 30, and check that the data is “00”.
11) When 4F page is initialized, perform “VIDEO OUT Default
Data Check” and “Initial Language Data Check”.
12) When 8F page is initialized, perform “Exif Model Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
B
A
03
Page of 32
Display

Click on the first or last page to see other DSC-W30 (serv.man3) service manuals if exist.