Sony DSC-W120 / DSC-W125 (serv.man3) Service Manual ▷ View online

6-6
DSC-W120/W125_ADJ
Ver. 1.3  2008.06
4.
Precautions When Using Pattern Box
1) It takes about 30 minutes for pattern box to stabilize its brightness.
Turn on the pattern box 30 minutes before the adjustment starts.
2) Make arrangement so that the outside light does not enter the chart surface in the pattern box.
Also, place a board between chart and camera, and make a hole at the lens part of the board so that the camera is not reflected in the
shot image screen.
(Adjustment may not be performed correctly due to the influence of outside light.)
Example 1:
Place a box to block a section between pattern box and camera.
Example 2:
Place a board having a hole in front of the camera and cover the pattern box and camera with a blackout curtain
3) Control of color chart
The color chart will fade if it is exposed to direct sunlight or strong light.
Since the fading of color chart progresses even with the light in the pattern box, remove and store the color chart when it is not used.
Remove the color chart and store it.
Store the color chart in a place not exposed to direct light, avoiding high temperature and humidity.
Use the color chart for about three years, and afterward replace it with a new chart.
Pattern box
Front of the lens
Make the hole of the same
size as the lens. 
Make the hole of the same
size as the pattern box. 
L = About 9 cm
L
Camera
Pattern box
Front of the lens
Board that opens hole
to lens part
L = About 9 cm
L
Camera
Cover with a blackout curtain
6-7
DSC-W120/W125_ADJ
5.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B, C and D of 15 mm thickness.
2) Apply black mat paint to one side of woody board A, B and D.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B, C and D are internal. (Fig. 6-1-7)
Fig. 6-1-6
Fig. 6-1-7
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
woody board D (1)
370 mm
370 mm
700 mm
730 mm
100 mm
120 mm
woody board A
woody board B
woody board B
woody board C
woody board A
woody board D
Fig. 6-1-8
Flash adjustment box
Front of the lens
Background paper
L = 50 cm
L
Camera
6-8
DSC-W120/W125_ADJ
3.
Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
Fig. 6-1-9
1
[Connecting the Equipment] button
A connection diagram of the equipment is displayed.
2
[CONNECT] button
The mode of camera is switched to the Adjustment Mode.
When the Adjustment Mode has switched normally, the op-
eration of the buttons 4 – 0 is enabled.
3
[END] button
The mode of camera is switched to the normal mode.
When the normal mode has switched correctly, the Automatic
Adjustment Program is finished.
4
[DESTINATION DATA WRITE] button
The “DESTINATION DATA WRITE” screen appears.
5
[USB SERIAL N0. INPUT] button
The “USB SERIAL No. INPUT” screen appears.
6
[VIDEO SYSTEM ADJUSTMENT] button
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
7
[CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
8
[LCD SYSTEM ADJUSTMENT] button
The “LCD SYSTEM ADJUSTMENT” screen appears.
9
[SERVICE MODE] button
The “SERVICE MODE” screen appears.
0
[DATA BACKUP] button
The “DATA BACKUP” screen appears.
qa
This part indicates the version of Automatic Adjustment Pro-
gram.
qs
[Adjust item] button
“Adjusting items when replacing main parts and boards” table
is displayed.
1-2.
ADJUSTMENT  PROGRAM
The DSC-W120/W125 is adjusted by the Automatic Adjustment
Program. The Automatic Adjustment Program enters automatically
via the SeusEX the adjustment operations that were formerly en-
tered manually by the adjustment remote commander (some items
may be adjusted by manual operation on the operation screen of
the SeusEX).
1.
Precautions When Using Automatic Adjustment
Program
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi-
cation with the camera via the SeusEX. Accordingly, the Au-
tomatic Adjustment Program must be used in the environment
where the SeusEX operates.
2) The Automatic Adjustment Program cannot be used when the
SEUS or the SeusCam is running. Exit the SEUS or the
SeusCam before using the Automatic Adjustment Program.
3) The SeusEX must be already started on the PC when using the
Automatic Adjustment Program. With the SeusEX not started,
some adjustment items will take time in adjustment.
4) The program run time may vary depending on the environ-
ment of the personal computer used.
2.
Start of Automatic Adjustment Program
Double-click the application file (DSC-W120_W125 Auto-Adj
Ver_1.5r06.exe), and the Automatic Adjustment Program will start.
3
5
4
7
6
2
1
qs
9
0
8
qa
Ver. 1.5  2009.03
6-9
DSC-W120/W125_ADJ
4.
Setting of Adjustment Mode
Before performing the adjustment, “Setting of Adjustment Mode”
is required.
[Setting method]
1) Connect the Camera to the PC with a USB cable, and turn on
the power switch.
2) Start the Automatic Adjustment Program, and click the [Con-
nect] button on the Main Menu screen.
3) Turn off the power button of the set when the following mes-
sage is displayed.
4) Once turn off a set completely by pulling a “DC In Jack” (Or
you can pull a Multi-connector).
5) Connect a “DC In Jack” again and turn on a set by the power
button of a body.
Click the [OK]  button on the message screen when the set
started.
6) Upon successful completion of the settings in the Adjustment
Mode, the operation of each button on the Main Menu screen
is enabled.
5.
Release of Adjustment Mode
To finish the adjustment, be sure to perform “Release of Adjust-
ment Mode”.
[Releasing method]
1) Click the [END] button on the Main Menu screen.
2) When the following message is displayed, releasing of adjust-
ment mode has completed. Click the [OK] button in the mes-
sage window to exit the Automatic Adjustment Program.
Note:
The Camera switches to the normal mode by turning
off and on the power switch. After the adjustment fin-
ished, turn off and on again the power switch of the
Camera to confirm that the USB mode screen is dis-
played.