6-15
2.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 2 Start]
 button.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
Fig. 6-1-19
4) Click the 
[OK]
 button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
Fig. 6-1-20
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-21
6-16
DSC-W1/W12
3.
Picture Frame Setting (Standard Picture Frame)
In the “Color Shading Adjustment” and “CAMERA Adjustment
3”, set the picture frame so as to attain the positions shown in the
following figure when shooting the color bar chart.
Check on the oscilloscope
Measurement Point: Video terminal of A/V OUT jack
(75
Ω terminated)
1. Horizontal period
Fig. 6-1-22
2. Vertical period
Fig. 6-1-23
Check on the monitor TV
Fig. 6-1-24
B
A
C
A = C =
B
2
E = F
V
E
F
Color bar chart picture frame
Effective picture frame
A
B
C
E
F
A = C =
E = F
B
2
DSC-W1/W12
6-17
4.
Color Shading Adjustment
[Adjustment method]
1) Start the Color Shading Adjustment Program
(W1P100ColorShade.exe).
2) Select “DSC-W1” with the Model Select radio button.
Fig. 6-1-25
3) Click the 
[Connect]
  button to set the camera to the adjust-
ment mode.
Fig. 6-1-26
4)
Adjust the mode dial of the camera to “P” and with the zoom
at WIDE end, shoot the color bar chart.
5)
Adjust the camera direction and distance to set the picture frame.
(Refer to 3. Picture Frame Setting)
6)
Remove the color bar chart in the pattern box, and set the clear
chart.
Note:
At this time, nothing must be reflected in the clear chart.
7)
Click the 
[Color Shading Adjustment]
 button.
Fig. 6-1-27
8)
A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-28
9) Upon successful completion of the adjustment, the following
message is displayed. Click the 
[OK]
 button.
Fig. 6-1-29
6-18
DSC-W1/W12
5) Upon successful completion of the “AWB 3200K Check”, the
following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-32
6) Click the 
[OK]
 button, and the “7. AWB 5800K Standard Data
Input” and “8. AWB 5800K Check” will be executed.
7) Upon successful completion of the “AWB 5800K Check”, the
following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-33
8) Click the 
[OK]
 button, and the “9. AWB 3200K Check” and
“10. CCD Linearity Check” will be executed.
9) Upon successful completion of “10. CCD Linearity Check”,
the following message is displayed. Change the chart in ac-
cordance with the message.
Fig. 6-1-34
5.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Mechanical Shutter Adj.
5. Light Value Adj.
6. AWB 3200K Standard Data Input
7. AWB 5800K Standard Data Input
8. AWB 5800K Check
9. AWB 3200K Check
10. CCD Linearity Check
11. Color Reproduction Adj.
12. CCD White Defect Compensation Check
13. CCD Black Defect Compensation Check
14. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 3 Start]
 button.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-22 to
Fig. 6-1-24 (See page 6-16), set the subject and click the 
[OK]
button.
Fig. 6-1-30
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-31
4) Click the 
[OK]
 button, and the items from “3. F No. Compen-
sation” to “6. AWB 3200K Standard Data Input” will be ex-
ecuted.