DOWNLOAD Sony DSC-U40 (serv.man4) Service Manual ↓ Size: 359.82 KB | Pages: 31 in PDF or view online for FREE

Model
DSC-U40 (serv.man4)
Pages
31
Size
359.82 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-u40-sm4.pdf
Date

Sony DSC-U40 (serv.man4) Service Manual ▷ View online

DSC-U40
6-6
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-7)
Fig. 6-1-6
Fig. 6-1-7
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
woody board A
woody board B
woody board B
woody board C
woody board A
DSC-U40
6-7
1-2.
INITIALIZATION  OF  2F,  4F,  5F,  6F  PAGE
DATA
1-2-1.
Initialization of 2F, 4F, 5F, 6F Page Data
1.
Initializing of 2F, 4F, 5F, 6F Page Data
Note 1:
Initialize the data every page of 2F, 4F, 5F and 6F.
Note 2:
If the 4F page data has been initialized, the following
adjustments need to be performed again.
1) LCD system adjustments
Note 3:
If the 6F page data has been initialized, the following
adjustments need to be performed again.
1) Camera system adjustments
Adjusting Page
2F
Adjusting Address
10 to 73
Adjusting Page
4F
Adjusting Address
00 to FF
Adjusting Page
5F
Adjusting Address
00 to FF
Adjusting Page
6F
Adjusting Address
00 to FF
Initializing Method:
1) Click 
[Page Edit]
 on the SEUS screen to display the SEUS
PAGE EDIT screen.
2) Click 
[Page]
, and then enter the page to be initialized.
3) Click 
[Preset Data Read]
 to display the Set ID input screen.
4) Enter Set ID = “6” and read the initializing data on the SEUS
PAGE EDIT screen.
5) On the SEUS PAGE EDIT screen, change the data at “Fixed
data-2” address given in the table on the page to be initialized.
Note:
New data for change are not listed in the table. If the
data are to be changed, read and copy the data from the
same model. Copying the data from different models
may cause an operation failure.
6) Confirm that the data at respective adjustment addresses are
the initial values (adjustment initial values) given in the table.
If different, change to the adjustment initial values.
7) Click 
[Write]
 to write the initializing data to the set.
8) Click 
[Close]
 to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
6F
00
20 
[Write]
2
20
00
29 
[Set]
3
20
01
29 
[Set]
(Note)
Note:
At this time, the set is reset and the power is turns off once
and then on again. Accordingly, the message “Receive
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click 
[Connect]
 on the SEUS screen to restore the “con-
nected” state.
2.
2F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 4 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 5 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Address
Initial value
Remark
10 to 20
Fixed data-1 (Initialized data)
21
00
Test mode
22 to 73
Fixed data-1 (Initialized data)
3.
4F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 4 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 5 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Address
Initial value
Remark
00 to 1F
Fixed data-1 (Initialized data)
20
21
Fixed data-2
22 to 71
Fixed data-1 (Initialized data)
72
88
V-COM adj. (LCD)
73
A4
Bright adj. (LCD)
74, 75
Fixed data-1 (Initialized data)
76
8C
White balance adj. (LCD Light ON)
77
7C
(LCD)
78
63
Contrast adj. (LCD)
79 to 7F
Fixed data-1 (Initialized data)
80
90
White balance adj. (LCD Light OFF)
81
82
(LCD)
82 to A7
Fixed data-1 (Initialized data)
A8
Fixed data-2
A9 to FF
Fixed data-1 (Initialized data)
4.
5F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 4 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 5 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
DSC-U40
6-8
5.
6F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 4 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 5 of “1. Initializing of 2F, 4F, 5F, 6F Page
Data”)
Address
Initial value
Remark
00 to 0F
Fixed data-1 (Initialized data)
10
10
11
00
12
10
Flange back check
13
00
14
00
15
FF
16, 17
Fixed data-1 (Initialized data)
18
10
19
00
1A
10
1B
00
Flange back adj.
1C
10
1D
1D
1E, 1F
Fixed data-1 (Initialized data)
20
00
21
00
22
00
23
00
24
20
25
20
Flange back adj.
26
00
27
02
28
02
29
00
2A
00
2B
00
2C to 3D
Fixed data-1 (Initialized data)
3E
FF
Flange back adj.
3F to 51
Fixed data-1 (Initialized data)
52
00
Flange back adj.
53
00
54 to 57
Fixed data-1 (Initialized data)
58
44
59
A9
5A
15
5B
5B
Hall adj.
5C
79
5D
5D
5E
13
5F
42
60
00
F No. compensation
61
00
Address
Initial value
Remark
62
00
63
00
F No. compensation
64
00
65
3E
66
00
Light value adj.
67
A3
68
10
Hall adj.
69 to 6F
Fixed data-1 (Initialized data)
70
2F
71
81
72
1F
AWB 3200K standard data input
73
81
74
2F
75 to 7B
Fixed data-1 (Initialized data)
7C
1D
7D
01
7E
31
AWB 5800K standard data input
7F
01
80 to 87
Fixed data-1 (Initialized data)
88
00
89
00
8A
00
8B
00
8C
00
CCD linearity check
8D
00
8E
00
8F
00
90 to 99
Fixed data-1 (Initialized data)
9A
00
CCD linearity check
9B
00
9C to 9F
Fixed data-1 (Initialized data)
A0
2A
A1
00
A2
60
AWB 5800K standard data input
A3
00
A4
F4
A5
F1
A6
6A
A7
88
A8
FC
Color reproduction data input & check
A9
FF
AA
7A
AB
6C
AC to AF
Fixed data-1 (Initialized data)
B0
00
Mixed color cancel data input & check
B1
00
B2
00
AWB 3200K standard data input
B3
00
AWB 5800K standard data input
DSC-U40
6-9
Address
Initial value
Remark
B4
00
AWB 3200K standard data input
B5
Fixed data-1 (Initialized data)
B6
28
Strobe adj.
B7
6E
B8
09
B9
39
BA
06
BB
6A
BC
06
BD
03
BE
00
BF
00
C0
00
C1
00
C2
00
C3
00
C4
00
C5
00
C6
00
C7
44
Mechanical shutter adj.
C8
5B
C9
69
CA
00
CB
00
CC
80
CD
88
CE
98
CF
90
D0
88
D1
00
D2
00
D3
00
D4
00
D5
00
D6
00
D7
14
D8 to D9
Fixed data-1 (Initialized data)
DA
00
DB
00
DC
00
DD
00
DE
00
DF
00
Strobe adj.
E0
00
E1
00
E2
00
E3
00
E4
00
6F Page table
Address
Initial value
Remark
E5
00
E6
00
E7
00
E8
00
E9
00
EA
00
Strobe adj.
EB
00
EC
00
ED
00
EE
00
EF
00
F0 to FF
Fixed data-1 (Initialized data)
Page of 31
Display

Click on the first or last page to see other DSC-U40 (serv.man4) service manuals if exist.