DOWNLOAD Sony DSC-T90 (serv.man2) Service Manual ↓ Size: 4.4 MB | Pages: 63 in PDF or view online for FREE

Model
DSC-T90 (serv.man2)
Pages
63
Size
4.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera
File
dsc-t90-sm2.pdf
Date

Sony DSC-T90 (serv.man2) Service Manual ▷ View online

1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DSC-T90_L2
1-5-3. Self-diagnosis Code Table
C
C
E
E
E
E
E
E
E
E
E
Block
Function
1
3
3
2
6
1
6
1
6
2
6
2
6
2
6
2
6
2
9
1
9
2
Detailed
Code
0
1
0
1
0
0
1
0
0
2
1
0
1
1
1
2
2
0
0
1
0
0
Symptom/State
The internal memory has experienced a
 media error.
The internal memory has experienced a
format error.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
“Memory Stick Duo” type error
The camera cannot read or write data
on the “Memory Stick Duo”.
Trouble with hardware
Difficult to adjust focus
(Cannot initialize focus)
Zoom operations fault
(Cannot initialize zoom lens.)
Abnormality of IC for steadyshot.
Lens initializing failure.
Lens overheating (PITCH).
Lens overheating (YAW).
Abnormality of thermistor.
Abnormality when flash is being charged.
Non-standard battery is used.
Self-diagnosis Code
Repaired b
y:
Correction
Turn the power off and on again.
Format the internal memory.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Insert a supported “Memory Stick Duo”.
Turn the power off and on again, or taking out and inserting the
“Memory Stick Duo” several times.
Turn the power off and on again.
Retry turn the power on by the power switch. If it does not
recover, check the focus reset sensor of lens block (pin w; of
CN401 on the SY-226 board). If it is OK, check the focus motor
drive IC (IC401 on the SY-226 board).
Retry turn the power on by the power switch. Check the zoom
reset sensor of lens block (pin wk of CN401 on the SY-226
board), if zooming is performed when the zoom button is
operated. If it is OK, check the zoom motor drive IC (IC401 on
the SY-226 board).
Check or replacement of the IC for steadyshot (IC401 on the SY-
226 board).
Check or replacement of the IC for steadyshot (IC401 on the SY-
226 board).
Check the HALL element (PITCH) of optical image stabilizer
(pin q;, qa of CN401 on the SY-226 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE401 on the SY-226
board) peripheral circuits.
Check the HALL element (YAW) of optical image stabilizer (pin
7
, qs of CN401 on the SY-226 board). If it is OK, check
PITCH/YAW angular velocity sensor (SE401 on the SY-226
board) peripheral circuits.
Check the OIS temp sensor of optical image stabilizer (pin qk of
CN401 on the SY-226 board).
Checking of flash unit or replacement of flash unit. (Note)
Use the compatible battery only.
Note:
After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
1-6
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DSC-T90_L2
1-6. PROCESS  AFTER  FIXING  FLASH  ERROR
When “FLASH error”  (Self-diagnosis Code  E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the HOME screen.
Method for Initializing the Flash Error Code
Initializes the setting to the default setting. 
Even if you execute this function, the images are retained.
1
t
 
 (Settings) 
t
 [Main Settings] 
t
t
 [Initialize] 
t
t
 [OK] 
• Be sure not to turn off the camera while initializing.
Note
1-7
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DSC-T90_L2
1. SERVICE  NOTE
1-1. SY-226基板交換時の注意
リストアデータ
補修用基板と交換する時,交換前の基板より調整に必要となるデータを取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「Restore Data」を実行させてください。
本機で取得されるデータは下記になります。
• USB Serial No.
• Angular Velocity Sensor Sensitivity Adjustment (Dp/Dy/Fpy Data)
• Wide Limit Adjustment
Note:交換前の基板よりデータが読み取れない場合は,SY-226基板とレンズを同時に交換する必要があります。
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「Destination Data Write」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB Serial No. Input」を実行させてください。
角速度センサ
補修用基板と交換する時,角速度センサ(SE401)の感度表示を書き留めてください
Adjust StationからAdjust Manualを起動させて「Angular Velocity Sensor Sensitivity Adjustment」を実行させて書き留めたデータ
を入力してください。
Note:SY-226基板のSE401感度表示は補修用基板にしか記載されておりません。
1-2. レンズ交換時の注意
XX
YY
F
N
L
1
/L
2
Wide Limit Data (2-byte data)
XXYY
YAW data
PITCH/YAW Data
PITCH data
P.PP / Y.YY
FN Data
FN data
XX
Note:PITCH/YAWデータ,FNデータおよびW端調整データ
は,補修用部品にのみ記載されています。
SE401
SY-226 BOARD (SIDE A)
PPP
YYY
PPP : PITCH sensor sensitivity
YYY : YAW sensor sensitivity
レンズ交換時,補修用レンズ添付のPITCH/YAWデータ,
F N データおよびW 端調整データを書き留めてください。
Adjust StationからAdjust Manualを起動させて「Wide Limit
Adjustment」,「Angular  Velocity  Sensor  Sensitivity
Adjustment」を実行させて書き留めたデータを入力してく
ださい。
1-8
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DSC-T90_L2
内蔵メモリーのコピー方法
内蔵メモリーのフォーマット方法
1
2
(メモリー管理)
[メモリーツー
ル]
[コピー]
[実行]
ご注意
充分に充電したバッテリーをご使用ください。残量の少ないバッテリーを使用して画像ファイルを
コピーすると、バッテリー切れのためデータを転送できなかったり、データを破損するおそれがあり
ます。
画像ごとのコピーはできません。
データをコピーしても、内蔵メモリー内のデータは削除されません。内蔵メモリーの内容を消去す
[フォーマット]を行ってください。
のフォルダを指定することはできません。
ありません。
1
(メモリー管理)
[メモリーツー
ル]
[フォーマット]
[実
行]
ご注意
フォーマットすると、プロテクトしてある画像も含めて、すべてのデータが消去され、元に戻せませ
ん。
1-3. 内蔵メモリーのデータコピーおよび消去方法
内蔵メモリーのデータコピーまたは消去はホーム画面の操作から実行可能です。(消去する場合は内蔵メモリーの初期化を
行います。)
Note 1: SY-226基板交換の際は,基板交換前に内蔵メモリーのデータを消去して下さい。
Note 2: SY-226基板交換の際は,基板交換後に内蔵メモリーのフォーマットおよび初期化を実行して下さい。
Page of 63