Sony DSC-T9 (serv.man4) Service Manual ▷ View online
6-4
DSC-T9_ADJ
Method for formatting the Music
If you cannot play back a Music file for the Slide Show, the Music file might be corrupted. If
this happens, perform [Format Music].
When [Format Music] is performed, all the Music files are erased. Use the supplied software
“Music Transfer” to activate [Download Music].
this happens, perform [Format Music].
When [Format Music] is performed, all the Music files are erased. Use the supplied software
“Music Transfer” to activate [Download Music].
The message “All data will be erased Ready?” appears.
Format Music
OK
Formats the Music files. All data other than Music files
remain as it is.
remain as it is.
Cancel
Cancels the formatting.
Ver. 1.1 2005.11
6-5
DSC-T9_ADJ
Replaced parts
Block
Mounted parts
Board
replacement
replacement
replacement
Adjusting item
Adjustment
LCD unit
Back light unit
(AF illumination LED)
(Timing gen., CCD signal process)
(Camera DSP)
(Video amp.)
(64M super AND) (Note 4)
(YAW, PITCH sensor)
LCD901
D901
D002
IC101
IC301
IC605
IC401
SE501, SE502
(COMPLETE)
(COMPLETE) (Note 3, 4, 5)
Lens block
CCD block assy (Including CD-597 flexible board and CCD imager)
Flash unit
LCD block
LCD block
ST-131 board
SY-141 board
SY-141 board
SY-141 board
SY-141 board
SY-141 board
ST-131 board
SY-141 board
VIDEO adjustment
Video output level adj.
z
z
z
CAMERA adjustment 1
Hall adj.
z
z
(Note 1)
Wide limit adj.
z
z
CAMERA adjustment 2
Flange back adj.
z
z
z
CAMERA adjustment 3
Flange back check
z
z
z
F No. compensation
Measure gain adj.
Mechanical shutter adj.
Light value adj.
(Note 2)
AWB 3200K-5800K standard data input
z
z
z
Color reproduction adj. & check
CCD linearity check
CCD white defect compensation check
CCD black defect compensation check
CAMERA adjustment 6
Strobe adj.
z
z
z
z
z
CAMERA adjustment 7
Auto focus illumination check
z
z
z
(Note 1)
Angular velocity sensor sensitivity adj.
z
z
z
V-COM adj.
White Balance adj.
(Note 1)
Initialization of data
z
z
LCD adjustment
CAMERA adjustment 4
z
z
CAMERA adjustment 5
z
z
z
z
z
z
1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table.
Note 1:
The automatic Adjustment Program does not support the “Initialization of data” , “Wide Limit Adjustment” and “Angular Veloc-
ity Sensor Sensitivity Adjustment”. Perform them manually.
ity Sensor Sensitivity Adjustment”. Perform them manually.
Note 2:
Use the AWB Adjustment Program (T9AwbAdjustment.exe).
Note 3:
When replacing the SY-141 board, erase the data in internal memory of the board before replacement.
Note 4:
When replacing the SY-141 board or the IC401 on the SY-141 board, execute formatting and initialize the internal memory after
replacement.
replacement.
Note 5:
When replacing the SY-141 board, perform “VIDEO OUT Default Data Check” and “Initial Language Data Check” after re-
placement.
placement.
Table 6-1-1
6-6
DSC-T9_ADJ
1-2. List of service tools
• Oscilloscope
• Color monitor
Fig. 6-1-1
Note 1:
Personal computer
OS:
OS:
Windows98/98SE/Me/2000/XP Home/XP Pro
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Note 2:
In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it matches
to the pattern box PTB-450.
1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black.
2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
to the pattern box PTB-450.
1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black.
2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
Fig. 6-1-2
360 mm
155 mm
280 mm
woody boad A
woody boad A
9 colors chart
135 mm
Personal computer
(Note 1)
(Note 1)
J-1
J-10
J-9
J-7
HASP key and application
for adjustment (SEUS)
for adjustment (SEUS)
Contact our service headquater of each area
how to get the application for adjustment
(SEUS) and HASP key.
how to get the application for adjustment
(SEUS) and HASP key.
J-2
Pattern box PTB-450
J-6082-200-A
or
Small pattern box
PTB-1450
J-6082-557-A
J-6082-200-A
or
Small pattern box
PTB-1450
J-6082-557-A
J-4
Clear chart
For PTB-450:
J-6080-621-A
J-6080-621-A
For PTB-1450:
J-6082-560-A
J-6082-560-A
J-6
Minipattern box
J-6082-353-B
J-6082-353-B
Siemens star chart
J-6080-875-A
J-6080-875-A
Back ground paper
J-2501-130-A
J-2501-130-A
9 colors chart (Note 2)
For PTB-1450:
J-6082-562-A
J-6082-562-A
J-5
USB, A/V, DC IN cable
for multi-use terminal
1-830-848-11
for multi-use terminal
1-830-848-11
J-3
J-8
Flange back
adjustment jig
J-6082-563-A
adjustment jig
J-6082-563-A
AC power adaptor
AC-LS5
1-479-284-12
AC-LS5
1-479-284-12
J-11
6-7
DSC-T9_ADJ
Fig. 6-1-4
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS
1-1-1.
Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
2) Start up the application for adjustment (SEUS).
Note:
Before perform the adjustment, set the following data.
1) Select page: 40, address: 38 and set data: 00.
1) Select page: 40, address: 38 and set data: 00.
Fig. 6-1-3
PC
(The SEUS must be installed in the PC.)
OS: Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Audio
(Black)
(Black)
Video
(yellow)
(yellow)
Color monitor
Video system Adjustment
Osilloscope
Terminated
75
75
Ω
AC IN
AC power adaptor
AC-LS5
(1-479-284-12)
AC-LS5
(1-479-284-12)
USB, A/V, DC IN cable
for multi-use terminal
(1-830-848-11)
for multi-use terminal
(1-830-848-11)
HASP Key
To DC IN jack
To Multi connector
To USB
connector
connector
DISP SEL switch setting
TV: Video/Camera
System Adjustment
System Adjustment
CAMERA: LCD System
Adjustment
Adjustment
Pattern box
Front of the lens
L = About 11 cm
L
Camera