6-8
DSC-T500_ADJ
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
woody board D (1)
370 mm
370 mm
700 mm
730 mm
100 mm
120 mm
woody board A
woody board B
woody board B
woody board C
woody board A
woody board D
Flash adjustment box
Front of the lens
Background paper
L = 50 cm
L
Camera
5.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B, C and D of 15 mm thickness.
2) Apply black mat paint to one side of woody board A, B and D.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B, C and D are internal. (Fig. 6-1-8)
Fig. 6-1-7
Fig. 6-1-8
Fig. 6-1-9
6-9
DSC-T500_ADJ
3.
Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-10 will appear. On this screen, select each ad-
justment section.
screen in Fig. 6-1-10 will appear. On this screen, select each ad-
justment section.
Fig. 6-1-10
1
[Connecting the Equipment] button
A connection diagram of the equipment is displayed.
A connection diagram of the equipment is displayed.
2
[CONNECT] button
The SeusZ starts to make the set in the connected state.
Upon successful connection, the operation of the buttons 4 –
qa
The SeusZ starts to make the set in the connected state.
Upon successful connection, the operation of the buttons 4 –
qa
is enabled.
3
[END] button
The Automatic Adjustment Program is finished.
The Automatic Adjustment Program is finished.
4
[INTERNAL MEMORY $Write Enable%] button
The “INTERNAL MEMORY (Write Enable)” screen appears.
The “INTERNAL MEMORY (Write Enable)” screen appears.
5
[DESTINATION DATA WRITE] button
The “DESTINATION DATA WRITE” screen appears.
The “DESTINATION DATA WRITE” screen appears.
6
[USB SERIAL N0. INPUT] button
The “USB SERIAL No. INPUT” screen appears.
The “USB SERIAL No. INPUT” screen appears.
7
[VIDEO SYSTEM ADJUSTMENT] button
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
8
[CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
9
[LCD SYSTEM ADJUSTMENT] button
The “LCD SYSTEM ADJUSTMENT” screen appears.
The “LCD SYSTEM ADJUSTMENT” screen appears.
0
[SERVICE MODE] button
The “SERVICE MODE” screen appears.
The “SERVICE MODE” screen appears.
qa
[DATA BACKUP] button
The “DATA BACKUP” screen appears.
The “DATA BACKUP” screen appears.
qs
This part indicates the version of Automatic Adjustment Pro-
gram.
gram.
qd
[Adjust item] button
“Adjusting items when replacing main parts and boards” table
is displayed.
“Adjusting items when replacing main parts and boards” table
is displayed.
1-2.
ADJUSTMENT PROGRAM
The DSC-T500 is adjusted by the Automatic Adjustment Program.
The Automatic Adjustment Program enters automatically via the
SeusZ the adjustment operations that were formerly entered manu-
ally by the adjustment remote commander (some items may be
adjusted by manual operation on the operation screen of the SeusZ).
The Automatic Adjustment Program enters automatically via the
SeusZ the adjustment operations that were formerly entered manu-
ally by the adjustment remote commander (some items may be
adjusted by manual operation on the operation screen of the SeusZ).
1.
Precautions When Using Automatic Adjustment
Program
Program
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi-
cation with the camera via the SeusZ. Accordingly, the Auto-
matic Adjustment Program must be used in the environment
where the SeusZ operates.
cation with the camera via the SeusZ. Accordingly, the Auto-
matic Adjustment Program must be used in the environment
where the SeusZ operates.
2) The Automatic Adjustment Program cannot be used when the
SEUS, SeusCam, or SeusEX is running. Exit the SEUS,
SeusCam or SeusEX before using the Automatic Adjustment
Program.
SeusCam or SeusEX before using the Automatic Adjustment
Program.
3) The SeusZ must be already started on the PC when using the
Automatic Adjustment Program. With the SeusZ not started,
some adjustment items will take time in adjustment.
some adjustment items will take time in adjustment.
4) The program run time may vary depending on the environ-
ment of the personal computer used.
2.
Start of Automatic Adjustment Program
Double-click the application file (DSC-T500 Auto-Adj
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
3
5
4
7
6
2
1
qd
0
qa
8
9
qs
Ver. 1.1 2009.01
6-10
DSC-T500_ADJ
2.
INTERNAL MEMORY (Write Enable)
[Preparations]
• Insert the battery pack.
• Remove the Memory Stick.
• Insert the battery pack.
• Remove the Memory Stick.
[Procedure]
1) Click the [Activate Write Enable] button.
2) Upon completion of the setting change, the following mes-
1) Click the [Activate Write Enable] button.
2) Upon completion of the setting change, the following mes-
sage will be displayed.
3) Disconnect the lead wire from the GND of the modified multi-
output stand.
4) Disconnect the USB cable and reconnect the USB cable to
activate the MassStorage mode for the USB connection.
5) Write the data read out into the PC to the internal memory of
the camera.
6) Exit the adjustment program, and turn off the power of the
camera, and the write enable setting will be cancelled.
1-3.
INTERNAL MEMORY (Write Enable)
Usually, the camera has been set so as to disable the data writing
from the PC to the internal memory of the camera.
This setting must be changed temporarily when the data is to be
written to the internal memory such as a case after the board re-
placement.
from the PC to the internal memory of the camera.
This setting must be changed temporarily when the data is to be
written to the internal memory such as a case after the board re-
placement.
1.
Function of Each Button on INTERNAL MEMORY
(Write Enable) Screen
(Write Enable) Screen
Click the [INTERNAL MEMORY $Write Enable%] button on the Main
Menu screen, and the “INTERNAL MEMORY (Write Enable)”
screen in Fig. 6-1-11 will appear.
Menu screen, and the “INTERNAL MEMORY (Write Enable)”
screen in Fig. 6-1-11 will appear.
Fig. 6-1-11
1
[To Menu] button
Return to the main menu.
Return to the main menu.
2
[Activate Write Enable] button
Change the setting so that the data can be written to the inter-
nal memory.
Change the setting so that the data can be written to the inter-
nal memory.
3
[Procedure] button
Indicate the procedure.
Indicate the procedure.
1
2
3
6-11
DSC-T500_ADJ
1-4.
DESTINATION DATA WRITE
Note:
The DESTINATION DATA WRITE cannot be set with other
than the Service board.
than the Service board.
1.
Function of Each Button on Destination Data Write
Screen
Screen
Click the [DESTINATION DATA WRITE] button on the Main Menu
screen, and the “DESTNATION DATA WRITE” screen in Fig. 6-
1-12 will appear.
screen, and the “DESTNATION DATA WRITE” screen in Fig. 6-
1-12 will appear.
Fig. 6-1-12
1
[To Menu] button
Return to the main menu.
Return to the main menu.
2
Destination Check button
Current destination setting checked when the “DESTINATION
DATA WRITE” screen started is displayed.
When this button is clicked, the destination is checked and the
display is updated.
Current destination setting checked when the “DESTINATION
DATA WRITE” screen started is displayed.
When this button is clicked, the destination is checked and the
display is updated.
3
Destination List
Select the written destination.
Select the written destination.
Note:
Two types of SY-209 BOARD, COMPLETE (SER-
VICE) are exists.
The destination displayed in the Destination List var-
ies depending on the type of SY-209 Board.
VICE) are exists.
The destination displayed in the Destination List var-
ies depending on the type of SY-209 Board.
4
[Data Write] button
Write the destination data to the camera.
Write the destination data to the camera.
2.
Destination Data Write
[Writing method]
1) Select the written destination with the Destination List.
1) Select the written destination with the Destination List.
2) Click the [Data Write] button.
3) Following message will be appeared after completing data
writing.
4) After the destination data writing completed, click the Desti-
nation Check button to check the destination
Table 6-1-2
Japanese
English
French
German
Spanish
Italian
Portuguese
Simplified
Chinese
Traditional
Chinese
Dutch
Russian
Korean
Persian
Arabic
Thai
Malay
Swedish
Norwegian
Danish
Finnish
Polish
Czech
Hungarian
Turkish
Greek
JE3
JE
z
a
a
a
a
a
a
a
a
a
a
PAL
U2
US
z
a
a
a
a
a
NTSC
CA2
CND
z
a
a
a
a
a
NTSC
E15
z
a
a
a
a
a
a
a
a
a
a
PAL
E32
z
a
a
a
a
a
a
a
a
a
a
PAL
E33
a
a
z
a
a
a
a
a
a
a
a
NTSC
AU2
AUS
z
a
a
a
a
a
PAL
HK1
HK
z
a
a
a
a
a
a
a
a
a
a
PAL
CN2
CH
a
a
a
a
z
a
a
a
a
a
a
PAL
KR2
KR
a
a
a
a
a
a
z
a
a
a
a
NTSC
TH6
Thai
a
a
a
a
a
a
a
a
a
z
a
PAL
AR2
AR
a
a
z
a
a
a
a
a
a
a
a
NTSC
BR1
BR
a
a
a
z
a
a
a
a
a
a
a
NTSC
CEE2
a
a
a
a
a
a
a
z
a
a
a
a
a
a
a
a
a
PAL
CEE8
z
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
PAL
CEE9
z
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
PAL
CEH
UK
z
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
PAL
z
: INITIAL LANGUAGE
VIDEO OUT
Default
AEP
AREA
SELECTABLE LANGUAGE
SY-209
Board
SERVICE
124
SERVICE
35
E
DESTINATION
3
4
2
1
3.
Language that can be selected about SY-209 board
Click on the first or last page to see other DSC-T500 (serv.man3) service manuals if exist.