DOWNLOAD Sony DSC-T10 (serv.man4) Service Manual ↓ Size: 687.3 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-T10 (serv.man4)
Pages
37
Size
687.3 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-t10-sm4.pdf
Date

Sony DSC-T10 (serv.man4) Service Manual ▷ View online

6-31
DSC-T10_ADJ
1-7.
INITIALIZATION  OF  DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note: If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0E”.
4) Click  [All]  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-68 A)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Select page: 2F, address: 4E and set data: 47.
9) Select page: 40, address: 38 and set data: 00.
10) Click [Save] on the SEUS screen.
11) Select page: 80, address: 34, and check that the data is “00”.
12) Select page: 80, address: 30, and check that the data is “00”.
13) Perform “VIDEO OUT Default Data Check” and “Initial Lan-
guage Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 [Set]
(Note)
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click [Connect]
on the SEUS screen to restore the “connected” state. (In
case that the power does not turn on again, press the power
button.)
Fig. 6-1-68
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1: If the 6E or 6F or 78 or CE or CF page data have been
initialized, the following adjustment needs to be per-
formed again.
1) Camera system adjustments
Note 2: If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0E”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-68
B
)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) When 2F page is initialized, select page: 2F, address: 4E and
set data: 47.
9) Select page: 40, address: 38 and set data: 00.
10) Click [Save] on the SEUS screen.
11) Select page: 80, address: 34, and check that the data is “00”.
12) Select page: 80, address: 30, and check that the data is “00”.
13) When 4F page is initialized, perform “VIDEO OUT Default
Data Check” and “Initial Language Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 [Set]
(Note)
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click [Connect]
on the SEUS screen to restore the “connected” state. (In
case that the power does not turn on again, press the power
button.)
B
A
0E
6-32
DSC-T10_ADJ
6-2. SERVICE  MODE
1.
Setting the Test Mode
Page 40
Address A1,  A3
• Forced CAMERA mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
• Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 07.
• Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
• After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
6-33
DSC-T10_ADJ
3.
LED Check
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 8E, address: FE, and set data: 20.
3) Select page: 80, address: 12, and set data: 01.
4) Check that all LED are lit.
• SELF TIMER/AF ILLUMINATOR
• MS ACCESS
5) Select page: 80, address: 12, and set data: 00.
6) Select page: 8E, address: FE, and set data: 00.
7) Select page: 00, address: 01, and set data: 00.
8) Click [Disconnect] on the SEUS screen.
9) Disconnect the USB cable.
10) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
5.
Switch Check (2)
Page 40
Address 5A
Using method:
1) Select page: 40, address: 5A.
2) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00 When data = 01 When data = 02
Shutter button
(XAE LOCK SW)
OFF
ON
ON
(CONTROL SWITCH BLOCK (RL60530) S004)
Shutter button
(XSHUTTER SW)
OFF
OFF
ON
(CONTROL SWITCH BLOCK (RL60530) S004)
Function
When data = FF or 00
When data = 55
Steady shot button
OFF
ON
(CONTROL SWITCH BLOCK (RL60530) S003)
6-34
DSC-T10_ADJ
7. Mode Switch Check
Page 20
Addresses A3
Using method:
1) Select page: 20, addresses: A3.
2) By discriminating the read data, the state of the mode switch can be discriminated.
6-34E
6. Switch Check (3)
Page 20
Addresses A0, A1
Using method:
1) Select page: 20, addresses: A0 and A1.
2) By discriminating the read data, the pressed key can be dis-
criminated.
8. Self Diagnosis Code
6-34E
Note: After repair, be sure to execute the “Initialize” of the setup screen.
Address
Data
2B to 33
49 to 54
60 to 6C
A3
MOVIE
PLAY
CAMERA
(MODE DIAL0)
(BT-029 flexible)
(BT-029 flexible)
(BT-029 flexible)
(IC301 AB14)
(S005)
(S005)
(S005)
Address
Data
00 to 0F
22 to 3C
42 to 5C
6E to 88
9C to B5
C1 to DB
FF
A0
CONTROL UP
CONTROL RIGHT CONTROL DOWN CONTROL LEFT
CONTROL SET
(KEY AD0)
(SW51800 block)
(SW51800 block)
(SW51800 block)
(SW51800 block)
(SW51800 block)
_
No key input
 (IC301 AA13)
(S001)
(S002)
(S003)
(S004)
(S006)
A1
ZOOM T
ZOOM W
SCREEN DISPLAY
MENU
IMAGE SIZE/
SLIDE SHOW
(KEY AD1)
(SW51800 block)
(SW51800 block)
ON/OFF
(SW51800 block)
DELETE
(SW51800 block)
No key input
(SW51800 block)
(SW51800 block)
(IC301 W15)
(S005)
(S007)
(S008)
(S009)
(S010)
(S011)
Display Code
  C:32:ss
  C:13:ss
Countermeasure
Turn the power off and on again.
Format the “Memory Stick” or internal
memory.
Insert a new “Memory Stick”.
Cause
Trouble with hardware.
“Memory Stick” or internal memory is
unformatted.
“Memory Stick” is broken.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
  E:61:ss
  E:91:ss
Checking of lens drive circuit.
Checking of flash unit or replacement
of flash unit. (Note)
Abnormality when flash is being
charged.
Trouble with internal memory.
Turn the power off and on again.
When failed in the focus zoom
initialization.
INTERNAL MEMORY ERROR
_
  E:62:ss
Inspect angular velocity sensor
peripheral circuits.
Steady shot function does not work well.