DOWNLOAD Sony DSC-T10 (serv.man4) Service Manual ↓ Size: 687.3 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-T10 (serv.man4)
Pages
37
Size
687.3 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-t10-sm4.pdf
Date

Sony DSC-T10 (serv.man4) Service Manual ▷ View online

6-14
DSC-T10_ADJ
SEUS operation screen
Fig. 6-1-15
Check on the oscilloscope
Fig. 6-1-16
1-3-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Video Adj.
2. Video Output Level Adj.
3. Release of Data Setting during Video Adj.
[Specified value of video output level adj.]
Measurement Point
Video terminal of USB, A/V, DC
IN cable for multi-use terminal
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level:
A = 286 
± 5 mV (NTSC mode)
A = 300 
± 5 mV (PAL mode)
Burst level:
B = 286 
± 25 mV (NTSC mode)
B = 300 
± 25 mV (PAL mode)
[Adjusting method]
1) Click the [Start] button of the VIDEO Adjustment.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Video Adj.”.
3) If “1. Data Setting during Video Adj.” completed successfully,
the next message is displayed during the execution of “2. Video
Output Level Adj.”. Using the UP/DOWN key on the SEUS
Operation screen, adjust so that the sync level of the video
signals satisfies the specified value. After the adjustment, check
that the burst level of the video signals satisfies the specified
value, and click the [OK] button in the message.
Fig. 6-1-13
4) If the [OK] button button is clicked, “3. Release of Data Set-
ting during Video Adj.” will be executed.
5) Upon successful completion of all items of the VIDEO Ad-
justment, the following message is displayed. Click the [OK]
button.
Fig. 6-1-14
UP/DOWN key
H
A
B
6-15
DSC-T10_ADJ
1-4.
CAMERA  SYSTEM  ADJUSTMENTS
1-4-1.
Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CAMERA SYSTEM ADJUSTMENT”
screen in Fig. 6-1-17 will appear.
Fig. 6-1-17
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
Each adjustment from “Camera Adjustment 1” to “Camera
Adjustment 8” starts.
4
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the camera adjust-
ment 1-8. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
5
4
3
2
1
2
3
6-16
DSC-T10_ADJ
1-4-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-3. The Automatic Adjustment Program divides the ad-
justment items into eight, camera adjustment 1-8. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note 1: The Automatic Adjustment Program does not support the “Wide Limit Adjustment”.
Note 2: Dark Siemens star chart.
Note 3: Use the AWB Adjustment Program (T10AwbAdjustment.exe).
Table 6-1-3
_
_
_
_
_
_
_
_
Button Name
Adjustment
Subject
Adjustment
Page
Adjustment
Address
CAMERA Adjustment 1
Hall Adj.
Not required
CE
54 to 57
CF
12 to 29, B0 to C3, 
(Note 1)
Wide Limit Adj.
Not required
6F
18, 19
CAMERA Adjustment 2
Flange Back Adj.
Siemens star chart with ND filter
for minipattern box (Note 2) or
Flange back adjustment jig
6F
18 to 3F, 52, 53
CAMERA Adjustment 3
Flange Back Check
Siemens star
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
F No. Compensation
6F
60, 61, 6B to 6D
6F
6B, 6F
78
0C to 0F
Mechanical Shutter Adj.
6F
6B to 6D, B8 to BD,
C7 to C9
Light Value Adj.
6F
65 to 67
(Note 3)
AWB 3200K-5800K
Standard Data Input
9 color chart
(Standard picture frame)
6E
00 to 21, 24 to 49
Color Reproduction
Adj. & Check
9 color chart
(Standard picture frame)
6E
50 to 57
CCD Linearity Check
CCD White Defect
Compensation Check
CCD Black Defect
Compensation Check
6E
72 to 75
6F
D8 to EF
CAMERA Adjustment 7
Auto Focus Illumination Check
Flash adjustment box (50 cm)
6F
10 to 15
CAMERA Adjustment 8
Angular Velocity Sensor
Sensitivity Adj.
Not required
CF
0C, 0D
Strobe Adj.
Flash adjustment box (50 cm)
CAMERA Adjustment 6
Measure Gain Adj.
CAMERA Adjustment 4
Clear chart
(Standard picture frame)
Clear chart
(Standard picture frame)
CAMERA Adjustment 5
6-17
DSC-T10_ADJ
1-4-3.
Adjusting Method
1.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Hall Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, the following screen is displayed.
Fig. 6-1-18
4) If the [OK] button is clicked, “2. Hall Adj.” and “3. Release of
Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA Ad-
justment 1, the following message is displayed. Click the [OK]
button.
Fig. 6-1-19