DOWNLOAD Sony DSC-S40 (serv.man15) Service Manual ↓ Size: 456.97 KB | Pages: 29 in PDF or view online for FREE

Model
DSC-S40 (serv.man15)
Pages
29
Size
456.97 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS BRAZIL
File
dsc-s40-sm15.pdf
Date

Sony DSC-S40 (serv.man15) Service Manual ▷ View online

6-19
DSC-S40
1-4.
LCD  SYSTEM  ADJUSTMENTS
1-4-1.
Function of Each Button on LCD System
Adjustment Screen
Click the 
[LCD SYSTEM ADJUSTMENT]
  button on the Main
Menu screen, and the “LCD SYSTEM ADJUSTMENT” screen in
Fig. 6-1-36 will appear.
Fig. 6-1-36
1
[To Menu]
 button
The Main Menu screen comes back.
2
[Start]
 button
“LCD Adjustment” starts.
3
[Reset]
 button
This button functions same as the “Initialize” of the setup
screen.
4
[Release Data Setting]
 button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the LCD adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
4
3
2
1
1-4-2.
Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in
Table 6-1-3. The Automatic Adjustment Program executes the ad-
justment items if the LCD Adjustment Start button is clicked.
Button
Adjustment
Signal
Page
Address
Name
LCD
V-COM AC adj.
8F
10
V-COM adj.
Arbitrary
8F
11
Adjustment
White Balance adj.
8F
42, 43
Table 6-1-3
6-20
DSC-S40
1-4-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. EVR Data Write
2. System Reset
3. Data Setting during LCD Adj.
4. V-COM AC Adj.
5. V-COM Adj.
6. White Balance Adj.
7. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the LCD Adjustment.
2) The Automatic Adjustment Program executes the items from
“1. Data Setting during LCD Adj.” to “4. V-COM AC Adj.”.
3) Upon successful completion of the “4. V-COM AC Adj.”, the
following message is displayed during execution in “5. V-COM
Adj.”. On the SEUS screen, operate the UP/DOWN key so
that the brightness of portions A and B on the LCD panel is
equal. After the adjustment, click the 
[OK]
 button.
Fig. 6-1-37
4) Upon completion of “5. V-COM Adj.”, “6. White Balance Adj.”
is executed. The following message is displayed, and then check
that LCD screen is not colored.
If colored, change the data of page: 8F, address: 42 and 43 on
the SEUS Operation screen to adjust so that the LCD screen is
not colored.
Fig. 6-1-38
5) If the 
[OK]
 button is clicked, “7. Release of Data Setting dur-
ing LCD Adj.” will be executed.
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the 
[OK]
 button.
Fig. 6-1-39
SEUS operation screen
Fig. 6-1-40
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-41
UP/DOWN key
A
B
6-21
DSC-S40
1-5.
ERROR
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-5-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error
Fig. 6-1-42
Symptom
USB communication with the set is abnormal.
Cause
USB cable is not inserted tightly.
Power supply is not installed correctly.
Communication with SEUS is abnormal.
Remedy
Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
Install the power supply correctly.
Start the SEUS and click the 
[Connect]
  to
check that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-43
Symptom
The camera is not ready for adjustment.
Cause
Data error exists in the camera.
Remedy
Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-44
Symptom
Adjustment does not finish within the specified
time.
Cause
Adjustment conditions are wrong.
Data error exists in the camera.
Remedy
Check that the conditions such as a subject
are correct.
Reset the camera.
4.
Adjustment NG
Fig. 6-1-45
Symptom
The adjusted data does not become the speci-
fied value.
Cause
Adjustment conditions are wrong.
Data error exists in the camera.
Remedy
Check that the conditions such as a subject
are correct.
Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-22
DSC-S40
5.
Data Save Error
Fig. 6-1-46
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
Data writing to the flash memory failed.
Connection is faulty.
Power supply is not installed correctly.
Remedy
On the SEUS Operation screen, 
[Set]
 the data
to the pages and addresses displayed in the
message, and 
[Save]
  them. (Cancel manu-
ally the data setting during adjustment.)
Check the connection.
Install the power supply correctly.
1-5-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not
operate normally.
In this case, the 
[Release Data Setting]
  button is displayed in
“red” on the screen as shown in Fig. 6-1-47 and 48. Click the
[Release Data Setting]
 button to cancel the data setting. When
the data setting is cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred,  the 
[Release Data
Setting]
 button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Camera System Adjustment screen
Fig. 6-1-47
LCD System Adjustment screen
Fig. 6-1-48
How to cancel the 
data setting during 
adjustment is 
display here.
Page of 29
Display

Click on the first or last page to see other DSC-S40 (serv.man15) service manuals if exist.