DOWNLOAD Sony DSC-RX100M3 (serv.man3) Service Manual ↓ Size: 9.21 MB | Pages: 31 in PDF or view online for FREE

Model
DSC-RX100M3 (serv.man3)
Pages
31
Size
9.21 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-rx100m3-sm3.pdf
Date

Sony DSC-RX100M3 (serv.man3) Service Manual ▷ View online

DSC-RX100M3_L2
– 3 –
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH 
MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST 
ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPO-
NENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS 
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY 
SONY. 
ATTENTION AU  COMPOSANT  AYANT  RAPPORT 
À  LA  SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES 
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT 
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REM-
PLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT 
LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES 
SUPPLÉMENTS PUBLIÉS PAR SONY.
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
注意
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
UNLEADED SOLDER
This unit uses unleaded solder.
Boards requiring use of unleaded solder are printed with the lead free 
mark (LF) indicating the solder contains no lead.
(Caution:  Some printed circuit boards may not come printed with the 
lead free mark due to their particular size.)
: LEAD FREE MARK
Be careful to the following points to solder or unsolder.
•   Set the soldering iron tip temperature to 350 °C approximately. 
If cannot control temperature, solder/unsolder at high temperature 
for a short time.
Caution:  The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!  
Unleaded solder is more viscous (sticky, less prone to 
flow) than ordinary solder so use caution not to let solder 
bridges occur such as on IC pins, etc.
•   Be sure to control soldering iron tips used for unleaded solder and 
those for leaded solder so they are managed separately. Mixing un-
leaded solder and leaded solder will cause detachment phenomenon.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer.
1.  Check the area of your repair for unsoldered or poorly-soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or contact high-wattage resistors.
3.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
4.  Look for parts which, through functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
5.  Check the B+ voltage to see it is at the values specified.
6.  Flexible Circuit Board Repairing
 
•   Set the soldering iron tip temperature to 350 °C approximately.
 
•   Do not touch the soldering iron on the same conductor of the circuit 
board (within 3 times).
 
•   Be careful not to apply force on the conductor when soldering or 
unsoldering.
1.  注意事項をお守りください。
 
サービスのとき特に注意を要する個所については,キャビ
ネット,シャーシ,部品などにラベルや捺印で注意事項を
表示しています。これらの注意書き及び取扱説明書等の注
意事項を必ずお守り下さい。
2.  指定部品のご使用を
 
セットの部品は難燃性や耐電圧など安全上の特性を持った
ものとなっています。従って交換部品は,使用されていた
ものと同じ特性の部品を使用して下さい。特に回路図,部
品表に0印で指定されている安全上重要な部品は必ず指定
のものをご使用下さい。
3.  部品の取付けや配線の引きまわしはもとどおりに
 
安全上,チューブやテープなどの絶縁材料を使用したり,
プリント基板から浮かして取付けた部品があります。また
内部配線は引きまわしやクランパによって発熱部品や高圧
部品に接近しないよう配慮されていますので,これらは必
ずもとどおりにして下さい。
4.  サービス後は安全点検を
 
サービスのために取外したネジ,部品,配線がもとどおり
になっているか,またサービスした個所の周辺を劣化させ
てしまったところがないかなどを点検し,安全性が確保さ
れていることを確認して下さい。
5.  チップ部品交換時の注意
 
・  取外した部品は再使用しないで下さい。
 
・  タンタルコンデンサのマイナス側は熱に弱いため交換時
は注意して下さい。
6.  フレキシブルプリント基板の取扱いについて
 
・  半田こてのこて先温度は約350℃に設定してください。
 
・  同一パターンに何度もコテ先を当てないで下さい。(3回
以内)
 
・  パターンに力が加わらないよう注意して下さい。
サービス,点検時には次のことにご注意ください。
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(Lead Free)を意味する
レッドフリーマークがプリントされています。
(注意: 基板サイズによっては,無鉛半田を使用していてもレッ
ドフリーマークがプリントされていないものがありま
す)
:レッドフリーマーク
無鉛半田は,下記の点に注意して使用してください。
・  半田こてのこて先温度は約350℃に設定してください。
温度調節が無理な場合は,高温短時間で作業を行ってくだ
さい。
注意:  半田こてを長く当てすぎると,基板のパターン(銅
箔)がはがれてしまうことがありますので,注意して
ください。また,従来の半田よりも粘性が強いため,
IC端子などが半田ブリッジしないように注意してく
ださい。
・  半田こてのこて先は,必ず無鉛半田用と有鉛半田用に分け
て管理してください。
無鉛半田と有鉛半田が混在すると剥離現象が発生してしま
います。
– ENGLISH –
– JAPANESE –
注意
如果电池更换不当会有爆炸危险。
只能用同样类型或等效类型的电池来更换。
务必按照说明处置用完的电池。
DSC-RX100M3_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-1036 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No. INPUT
• Lens data carry
• AWB adj
• Light sensor adj
• Eye sensor adj
• EVF Data Input
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note: A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference from 
the ID registered by the customer.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC ad-
dress) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
1.  Download the latest-version Adjust Manual.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN check” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize.
 MENU 
→   → [Reset Network Set.] → [OK] → ●
5.  Perform the following operations for the unit to display MAC address.
 MENU 
→   → [Disp MAC Address] → ●
6.  Confirm that the displayed MAC address has been updated.
Applicable parts
•  SY-1036 BOARD, COMPLETE (SERVICE)
 
Note: The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
Perform the above operations after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, download the 
Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach it to the set when returning the set to customer.
– ENGLISH –
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE7701).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity ADJ”.
Type A:
Type B:
P Y
P Y
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
SY-1036 BOARD (SIDE A)
SE7701
Note: The sensor sensitivity of SE7701 of SY-1036 board is written only repair parts.
1-2.  NOTES ON REPLACING THE LENS
When replacing the lens, read the QR code of the repair lens.
To read the QR code, start the Adjust manual and press the QR code reader button.
The read data is used in the following processes.
•  Selection of Spacer Plate when mounting the imager board
•  Adjustment after replacing the lens
1-2-1.
 
Selection of Spacer Plate when Mounting the Imager Board
1.  Load the Spacer Plate on the QR code reader screen.
2.  The thickness of the Spacer Plate to be loaded is displayed.
 
3.  Select the Spacer Plate according to the instructions on the screen and mount the imager board.
1-2-2.
 
Adjustment after Replacing the Lens
Perform LOAD from “Lens data carry” on the ADJUST tab in the Adjust manual.
QR code
DSC-RX100M3_L2
1-2
– ENGLISH –
1-3.  NOTES ON REMOVING/INSTALLING THE IMAGER BOARD (CD-847 FLEXIBLE BOARD)
When the CD-847 Flexible Board (Imager) is mounted to the lens, shift and tilt adjustment is made with Spacer Plates.
When removing the CD-847 Flexible Board, pay attention to the following.
(1)  When the lens is not replaced
 
Example: In the case of disassembly, cleaning, or replacement of the CD-847 Flexible Board (Imager)
•  Check and record the size of the built-in three Spacer Plates and store them so as not to lose them.
•  When assembling the CD-847 Flexible Board, be sure to install the Spacer Plates to their original locations.
Size
0.xx
Note
Be careful not to lose the Spacer Plates.
If any Spacer Plate is lost or their previous positions are not sure, repeatedly take a photo and check that there is no local defocus. 
Selecting appropriate Spacer 
Plates
 is needed.
(2)  When the lens is replaced
 
Refer to “1-2. NOTES ON REPLACING THE LENS” for select Spacer Plates and install them to the new lens.
1-4.  NOTES FOR REPLACING THE EVF DISPLAY DEVICE (LCD902) OR THE SY-1036 BOARD
Adjustment values of each EVF display device (LCD902) are stored on the SY board.
Therefore, when the LCD902 or the SY board has been replaced, write adjustment values.
White balance value
Brightness value
2565687041A
Example of the label which is put on repairing EVF display device (LCD902)
Note:  When a label is mention such as the illustration, please read it follows.
 
Brightness value: 256
 
White balance value: 874
When LCD902 is replaced:
1.  Check and write down the adjustment values printed on the repairing EVF display device (LCD902) label.
2.  After the LCD902 has been replaced, execute “EVF Data Input” on the ADJUST tab by using the Adjust manual to write the adjustment values.
When replacing SY board (in case adjustment values can be read):
1.  In case the unrepaired unit starts and adjustment values can be read by using the Adjust manual, execute “ADJUSTMENT DATA BACKUP” on 
the DATA tab.
2.   After the SY board has been replaced with a SY board for repair, execute “ADJUSTMENT DATA BACKUP” on the DATA tab of the Adjust 
manual to write the extracted data to the unit.
When replacing SY board (in case adjustment values cannot be read):
Consult with each Head Quarters.
DSC-RX100M3_L2
1-3
– ENGLISH –
1-5.  CHECKING THE Wi-Fi FUNCTION
Perform the following procedure to check the Wi-Fi function.
Required equipment: Windows personal computer with Wi-Fi interface
1.  Turn on the power of the unit.
2.  Perform the following operations.
 MENU 
→   → [Application List] → [Smart Remote Embedded] → ●
3.  When preparation for Wi-Fi has been completed, the following screen opens and a password for Wi-Fi connection is displayed.
Smart Remote Embedded
Operate smartphone to connect to
this device via Wi-Fi.
SSID DIRECT-XXXX:DSC-XXXX
Password XXXXXXXX
Device Name DSC-XXXX
Wi-Fi
Exit App.
4.  Confirm on the personal computer that the unit is detected as a connectable wireless network.
5.  To further confirm that the unit is connectable, connect the unit to the personal computer and double-click the “current connection” from the icon 
displayed on the notice field, make sure that the unit is displayed in the Wireless internet access column.
1-6. SELF-DIAGNOSIS FUNCTION
1-6-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction 
manual.
1-6-2. Self-diagnosis Display
When problems occur while the unit is operating, the LCD screen shows 
a 4-digit display consisting of an alphabet and numbers, which blinks 
at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” 
in which the problem occurred, and “detailed code” of the problem.
0 0
3 2
C
Repaired by:
Refer to “1-6-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
1-6-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the 
memory card.
Turn the power off and on again, or taking out and inserting the 
memory card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
4
1
0
0
Abnormality of wireless LAN module or 
host  CPU.
Replace the SY-1036 board.
E
4
1
0
1
Abnormality of network control device.
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, 
check the focus MR sensor signal of lens block (pin 4, 5 of CN6800 
on the SY-1036 board). If it is OK, check the focus motor drive IC 
(IC6802 on the SY-1036 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset 
sensor signal of lens block (pin 1 of CN6800 on the SY-1036 board) 
when zooming is performed when the zoom button is operated. If it is 
OK, check the zoom motor drive IC (IC6802 on the SY-1036 board).
E
6
1
3
0
Reset position detection error on the stepper
iris initializing
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Check or replacement of the IC for steadyshot (IC6802 on the SY-
1036 board).
Page of 31
Display

Sony DSC-RX100M3 (serv.man3) Service Manual ▷ Download

  • DOWNLOAD Sony DSC-RX100M3 (serv.man3) Service Manual ↓ Size: 9.21 MB | Pages: 31 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DSC-RX100M3 (serv.man3) in PDF for free, which will help you to disassemble, recover, fix and repair Sony DSC-RX100M3 (serv.man3) Digital Camera. Information contained in Sony DSC-RX100M3 (serv.man3) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.