DSC-RX100M2_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-1021 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No.
• Angular Velocity Sensor Sensitivity adjustment
• AWB standard data input & check, Color reproduction check
• Strobe adjustment
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note:  A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC ad-
dress) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
1.  Download the latest-version Adjust Manual from the TISS homepage.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN check” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize.
 MENU 
→ 
 → [Initialize] → [Reset Network Settings] → [OK] → ●
5.  Perform the following operations for the unit to display MAC address.
 MENU 
→ 
 → [Disp MAC Address] → ●
6.  Confirm that the displayed MAC address has been updated.
Applicable parts
•  SY-1021 BOARD, COMPLETE (SERVICE)
Note: The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
Perform the above operations after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, print out the 
flyer given at the manual and attach it to the set when returning the set to customer.
– ENGLISH –
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE401).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity ADJ”.
SE401
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
Type A:
Type B:
Y P
Y P
SY-1021 BOARD (SIDE A)
Note: The sensor sensitivity of SE401 of SY-1021 board is written only repair parts.
DSC-RX100M2_L2
1-2
– ENGLISH –
1-2.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
Destination Ver. window
3)  Search the model whose new Destination Data file you want to get on the TISS homepage.
 
When the Destination Data file has been updated, a file with a name “Destination File For ‘model name’.zip” is registered.
(Example) Destination File For DSC-WX50.zip
Furthermore, the version supported by the Destination Data file is shown in the Remarks column.
Note : If the Destination Data file has not been updated, contact the Service Headquarters.
 4)  Download the Destination Data file of the relevant model and unzip the file.
5)  Execute “DESTINATION DATA WRITE” in the Adjust tab of the Adjust manual.
 
Click the [START] button.
DSC-RX100M2_L2
1-3
– ENGLISH –
6)  Click the [File Update] button in the window.
 
7)  A file selection screen opens. Select the Destination Data file to be added and click the [Open] button.
 
8)  When the file has been successfully added, the following window opens.
 
9)  Check the Destination Ver. window and confirm that the version has been updated.
Destination Ver. window
1-3.  NOTES ON REMOVING/INSTALLING THE IMAGER BOARD (CD-847 FLEXIBLE BOARD)
When the CD-847 Flexible Board (Imager) is mounted to the lens, shift and tilt adjustment is made with Spacer Plates.
When removing the CD-847 Flexible Board, pay attention to the following.
(1)  When the lens is not replaced
 
Example: In the case of disassembly, cleaning, or replacement of the CD-847 Flexible Board (Imager)
•  Check and record the size of the built-in three Spacer Plates and store them so as not to lose them.
•  When assembling the CD-847 Flexible Board, be sure to install the Spacer Plates to their original locations.
Size
0.xx
Note
Be careful not to lose the Spacer Plates.
If any Spacer Plate is lost or their previous positions are not sure, repeatedly take a photo and check that there is no local defocus. 
Selecting appropriate Spacer Plates
 
is needed.
(2)  When the lens is replaced
•  Check the size of the built-in three Spacer Plates. If the thickness of a Spacer Plate is not 0.20, discard the Spacer Plate.
•  Prepare three Spacer Plates B (t = 0.2) (Sony Part No.: 4-410-540-01) and install them to the new lens.
0.20
DSC-RX100M2_L2
1-4
– ENGLISH –
1-4.  CHECKING THE Wi-Fi FUNCTION
Perform the following procedure to check the Wi-Fi function.
Required equipment: Windows personal computer with Wi-Fi interface
1.  Turn on the power of the unit.
2.  Perform the following operations.
 MENU 
→ 
 → [Ctrl with Smartphone] → ●
3.  When preparation for Wi-Fi has been completed, the following screen opens and a password for Wi-Fi connection is displayed.
Ctrl with Smartphone
Operate smartphone to connect to
this device via Wi-Fi.
Enter
SSID DIRECT-XXXX:DSC-XXXXXXX
Password XXXXXXXX
Device Name DSC-XXXX
Wi-Fi
Cancel
4.  Confirm on the personal computer that the unit is detected as a connectable wireless network.
5.  To further confirm that the unit is connectable, connect the unit to the personal computer and select “Network and Internet” → “Manage Wireless 
Networks” from Control Panel to open the network connection list. The unit is included in the list.
1-5. SELF-DIAGNOSIS FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction 
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the LCD screen shows 
a 4-digit display consisting of an alphabet and numbers, which blinks 
at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” 
in which the problem occurred, and “detailed code” of the problem.
0 0
3 2
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
Page of 39
Display

Sony DSC-RX100M2 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony DSC-RX100M2 (serv.man2) Service Manual ↓ Size: 8.1 MB | Pages: 39 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DSC-RX100M2 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony DSC-RX100M2 (serv.man2) Digital Camera. Information contained in Sony DSC-RX100M2 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.