DOWNLOAD Sony DSC-RX1 / DSC-RX1R (serv.man2) Service Manual ↓ Size: 6.86 MB | Pages: 28 in PDF or view online for FREE

Model
DSC-RX1 DSC-RX1R (serv.man2)
Pages
28
Size
6.86 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-rx1-dsc-rx1r-sm2.pdf
Date

Sony DSC-RX1 / DSC-RX1R (serv.man2) Service Manual ▷ View online

DSC-RX1/RX1R_L2
– 3 –
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH 
MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST 
ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPO-
NENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS 
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY 
SONY. 
ATTENTION AU  COMPOSANT  AYANT  RAPPORT 
À  LA  SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES 
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT 
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REM-
PLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT 
LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES 
SUPPLÉMENTS PUBLIÉS PAR SONY.
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
注意
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
UNLEADED SOLDER
This unit uses unleaded solder.
Boards requiring use of unleaded solder are printed with the lead free 
mark (LF) indicating the solder contains no lead.
(Caution:  Some printed circuit boards may not come printed with the 
lead free mark due to their particular size.)
: LEAD FREE MARK
Be careful to the following points to solder or unsolder.
•   Set the soldering iron tip temperature to 350 °C approximately. 
If cannot control temperature, solder/unsolder at high temperature 
for a short time.
Caution:  The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!  
Unleaded solder is more viscous (sticky, less prone to 
flow) than ordinary solder so use caution not to let solder 
bridges occur such as on IC pins, etc.
•   Be sure to control soldering iron tips used for unleaded solder and 
those for leaded solder so they are managed separately. Mixing un-
leaded solder and leaded solder will cause detachment phenomenon.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer.
1.  Check the area of your repair for unsoldered or poorly-soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or contact high-wattage resistors.
3.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
4.  Look for parts which, through functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
5.  Check the B+ voltage to see it is at the values specified.
6.  Flexible Circuit Board Repairing
 
•   Set the soldering iron tip temperature to 350 °C approximately.
 
•   Do not touch the soldering iron on the same conductor of the circuit 
board (within 3 times).
 
•   Be careful not to apply force on the conductor when soldering or 
unsoldering.
1.  注意事項をお守りください。
 
サービスのとき特に注意を要する個所については,キャビ
ネット,シャーシ,部品などにラベルや捺印で注意事項を
表示しています。これらの注意書き及び取扱説明書等の注
意事項を必ずお守り下さい。
2.  指定部品のご使用を
 
セットの部品は難燃性や耐電圧など安全上の特性を持った
ものとなっています。従って交換部品は,使用されていた
ものと同じ特性の部品を使用して下さい。特に回路図,部
品表に0印で指定されている安全上重要な部品は必ず指定
のものをご使用下さい。
3.  部品の取付けや配線の引きまわしはもとどおりに
 
安全上,チューブやテープなどの絶縁材料を使用したり,
プリント基板から浮かして取付けた部品があります。また
内部配線は引きまわしやクランパによって発熱部品や高圧
部品に接近しないよう配慮されていますので,これらは必
ずもとどおりにして下さい。
4.  サービス後は安全点検を
 
サービスのために取外したネジ,部品,配線がもとどおり
になっているか,またサービスした個所の周辺を劣化させ
てしまったところがないかなどを点検し,安全性が確保さ
れていることを確認して下さい。
5.  チップ部品交換時の注意
 
・  取外した部品は再使用しないで下さい。
 
・  タンタルコンデンサのマイナス側は熱に弱いため交換時
は注意して下さい。
6.  フレキシブルプリント基板の取扱いについて
 
・  半田こてのこて先温度は約350℃に設定してください。
 
・  同一パターンに何度もコテ先を当てないで下さい。(3回
以内)
 
・  パターンに力が加わらないよう注意して下さい。
サービス,点検時には次のことにご注意ください。
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(Lead Free)を意味する
レッドフリーマークがプリントされています。
(注意: 基板サイズによっては,無鉛半田を使用していてもレッ
ドフリーマークがプリントされていないものがありま
す)
:レッドフリーマーク
無鉛半田は,下記の点に注意して使用してください。
・  半田こてのこて先温度は約350℃に設定してください。
温度調節が無理な場合は,高温短時間で作業を行ってくだ
さい。
注意:  半田こてを長く当てすぎると,基板のパターン(銅
箔)がはがれてしまうことがありますので,注意して
ください。また,従来の半田よりも粘性が強いため,
IC端子などが半田ブリッジしないように注意してく
ださい。
・  半田こてのこて先は,必ず無鉛半田用と有鉛半田用に分け
て管理してください。
無鉛半田と有鉛半田が混在すると剥離現象が発生してしま
います。
– ENGLISH –
– JAPANESE –
注意
如果电池更换不当会有爆炸危险。
只能用同样类型或等效类型的电池来更换。
务必按照说明处置用完的电池。
DSC-RX1/RX1R_L2
1-1
1. SERVICE  NOTE
1-1.  NOTES ON REPLACING THE SY-1001 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No.
• Angular Velocity Sensor Sensitivity adjustment
• AWB standard data input & check, Color reproduction check
• Strobe adjustment
• Lens data carry
Regarding the PlayMemories Home
PlayMemories Home has been written in internal memory.
The SY-1001 board for service is supplied with PlayMemories Home pre-installed.
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note:  A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Lens Data Carry
When replacing the main board, read the QR code given on the Data Carry QR Seal attached to the JK-1002 Flexible Board.
Start the Adjust Manual and read the QR code using a QR code reader.
To read data from the main board, execute [Lens data carry] on the ADJUST tab of the Adjust Manual and read the previous data before the main board 
is replaced using [ORIGINAL DATA READ AND SAVE].
The read data is used for adjustment after replacement. When adjustment, execute [LOAD] from [Lens data carry] on the ADJUST tab of the Adjust 
Manual.
1-2.  NOTES ON REPLACING THE LENS
When replacing the lens, read the QR code given on the data sheet of the replacement 
lens for service.
Remove the Data Carry QR Seal and stick it to the JK-1002 Flexible Board. (For details, 
refer to “Assembly-1: Notes on Assembling the IM Imager Unit and Lens Block.”)
Start the Adjust Manual and read the QR code using a QR code reader.
The read data is used for adjustment after replacement. When adjustments, Select [Lens 
data carry] on the ADJUST tab of the Adjust Manual, and click the [LOAD] button to 
load the file.
Data carry QR seal
– ENGLISH –
1-3.  NOTES ON REMOVING/INSTALLING THE IMAGER BOARD
With the following features, this unit is likely to capture foreign particles.
• The imager sensor size is large.
• The space between the imager sensor and the lens is small.
Therefore, pay close attention to foreign particles.
1-4.  NOTES ON REPLACING THE LSV-1600A DEVICE AND THE IM IMAGER UNIT
1)   When replacing the LSV-1600A Device or the IM Imager Unit, read values from the IM Data Carry Seal and the Lens Data Carry QR Seal shown 
in the figure below, and then write down the read values.
 
Lens data carry QR seal
IM data carry seal
Lens data carry QR seal 
(Describing lens tilting amount)
IM data carry seal  
(Describing imager tilting amount) 
00000014
-14.77   10.30
1058300067
X -5.8 
Y
 +0.7
2)  Start “Shim Selection Tool Ver_[].[].exe.”
 
Enter each recorded value into “Shim Selection Tool Ver_[].[].exe” according to the figure below, and then click [OK].
Note: Download “Shim Selection Tool Ver_[].[].exe” from the TISS homepage.
 
Lens data carry QR seal
IM data carry seal
Enter the values provided on the seats attached to the lens block
and the rear tube. Then click the [OK] button.
1058300067
X -5.8  Y +0.7
00000014
-14.77   10.30
DSC-RX1/RX1R_L2
1-2
– ENGLISH –
3)  The thicknesses of the shims to be used are displayed on the screen.
 
 
Select shims that correspond to the displayed thicknesses from following table.
Part Number
Thickness (mm)
Part Number
Thickness (mm)
4-443-059-01
0.12±0.005
4-443-060-31
0.38±0.005
4-443-059-11
0.14±0.005
4-443-060-41
0.40±0.005
4-443-059-21
0.16±0.005
4-443-060-51
0.42±0.005
4-443-059-31
0.18±0.005
4-443-060-61
0.44±0.005
4-443-059-41
0.20±0.005
4-443-060-71
0.46±0.005
4-443-059-51
0.22±0.005
4-443-060-81
0.48±0.005
4-443-059-61
0.24±0.005
4-443-060-91
0.50±0.005
4-443-059-71
0.26±0.005
4-443-061-01
0.52±0.005
4-443-059-81
0.28±0.005
4-443-061-11
0.54±0.005
4-443-059-91
0.30±0.005
4-443-061-21
0.56±0.005
4-443-060-01
0.32±0.005
4-443-061-31
0.58±0.005
4-443-060-11
0.34±0.005
4-443-061-41
0.60±0.005
4-443-060-21
0.36±0.005
4)  Install the imager and adjust the flange back.
1-5.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
Destination Ver. window
3)  Search the model whose new Destination Data file you want to get on the TISS homepage.
 
When the Destination Data file has been updated, a file with a name “Destination File For ‘model name’.zip” is registered.
(Example) Destination File For DSC-WX50.zip
Furthermore, the version supported by the Destination Data file is shown in the Remarks column.
Note : If the Destination Data file has not been updated, contact the Service Headquarters.
 
DSC-RX1/RX1R_L2
1-3
4)  Download the Destination Data file of the relevant model and unzip the file.
5)  Execute “DESTINATION DATA WRITE” in the Adjust tab of the Adjust manual.
 
Click the [START] button.
6)  Click the [File Update] button in the window.
 
– ENGLISH –
7)  A file selection screen opens. Select the Destination Data file to be added and click the [Open] button.
 
8)  When the file has been successfully added, the following window opens.
 
9)  Check the Destination Ver. window and confirm that the version has been updated.
Destination Ver. window
Page of 28
Display

Sony DSC-RX1 / DSC-RX1R (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony DSC-RX1 / DSC-RX1R (serv.man2) Service Manual ↓ Size: 6.86 MB | Pages: 28 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DSC-RX1 / DSC-RX1R (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony DSC-RX1 / DSC-RX1R (serv.man2) Digital Camera. Information contained in Sony DSC-RX1 / DSC-RX1R (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.