DOWNLOAD Sony DSC-P92 (serv.man4) Service Manual ↓ Size: 701.59 KB | Pages: 44 in PDF or view online for FREE

Model
DSC-P92 (serv.man4)
Pages
44
Size
701.59 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p92-sm4.pdf
Date

Sony DSC-P92 (serv.man4) Service Manual ▷ View online

6-8
DSC-P92
COVER
COVER
1-2.
INITIALIZATION OF 0E, 2F, 4F, 6F PAGE
DATA
1-2-1.
INITIALIZATION OF 2F PAGE DATA
1. Initializing the 2F Page Data
Adjusting page
2F
Adjusting Address
00 to 7F
Initializing Method:
1)
Select page: 00, address: 01, and set data: 01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
“2F”.
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input “0C” and click [OK] to read the preset data.
6)
On the SEUS PAGE EDIT screen, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8)
Click [Write] to write the initializing data to the EEPROM of
the camera.
9)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 2F Page data
Order Page Address Data
Procedure
1
20
00
29
Write the data.
2
20
01
29
Write the data.
3
Check “Receive Paket Error” is
displayed on the SEUS screen.
4
Turn on the power.
5
Click [Connect] on the SEUS
screen.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 20
21
22 to 7F
00
Test mode
Fixed data-1
2. 2F Page Table
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 2F Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 2F Page
Data”.)
Table. 6-1-2.
6-9
DSC-P92
1-2-2.
Initializing the 4F Page Data
1. Initializing the 4F Page Data
Note: If the 4F page data has been initialized, the following adjustments
need to be performed again.
1) Video system adjustments
2) LCD system adjustments
Adjusting page
4F
Adjusting Address
00 to FF
Initializing Method:
1)
Select page: 00, address: 01, and set data: 01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
“4F”.
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input “0C” and click [OK] to read the preset data.
6)
On the SEUS PAGE EDIT screen, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8)
Click [Write] to write the initializing data to the EEPROM of
the camera.
9)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 4F Page data
Order Page Address Data
Procedure
1
20
00
29
Write the data.
2
20
01
29
Write the data.
3
Check “Receive Paket Error” is
displayed on the SEUS screen.
4
Turn on the power.
5
Click [Connect] on the SEUS
screen.
2. 4F Page Table
Note1: Fixed data-1: Initialized data. (Refer to “1. Initializing the 4F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 4F
Page Data”.)
Address
Remark
Initial value
Address
Remark
Initial value
00 to 7E
80
81
82
83
84
85
86
87
88
89
8A
8B
8C to 91
92
93
94
95
98 to 9F
A0
A1 to A2
A3
A4
A5 to A7
A8
A9 to AB
AC
AD
AE
AF
B0 to FF
4E
FF
80
90
21
BD
08
3B
8E
77
39
36
29
07
1F
1F
80
28
00
00
00
00
00
Fixed data-1
Fixed data (LCD)
VCO adj. (LCD)
V COM adj. (LCD)
Bright adj. (LCD)
Fixed data (LCD)
PSIG level adj. (LCD)
White balance adj.
Contrast adj. (LCD)
VG center adj. (LCD)
Fixed data-1
Fixed data (LCD)
Fixed data-1
Video output level adj.
Fixed data-1
Fixed data (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Recording counter (Hexadecimal)
(Note2)
Fixed data-1
Table. 6-1-3.
Note2: Refer to “6-2. SERVICE MODE”.
6-10
DSC-P92
1-2-3.
Initializing the 6F Page Data
1. Initializing the 6F Page Data
Note: If the 6F page data has been initialized, the following adjustments
need to be performed again.
1) Camera system adjustments
Adjusting page
6F
Adjusting Address
00 to FF
Initializing Method:
1)
Select page: 00, address: 01, and set data: 01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
“6F”.
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input “0C” and click [OK] to read the preset data.
6)
On the SEUS PAGE EDIT screen, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8)
Click [Write] to write the initializing data to the EEPROM of
the camera.
9)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 6F Page data
Order Page Address Data
Procedure
1
20
00
29
Write the data.
2
20
01
29
Write the data.
3
Check “Receive Paket Error” is
displayed on the SEUS screen.
4
Turn on the power.
5
Click [Connect] on the SEUS
screen.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
FF
FF
FF
FF
FF
FF
FF
FF
36
54
87
71
10
C0
00
00
00
00
00
00
20
20
13
46
0A
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
FF
00
00
Fixed data-1
Auto focus illumination check
Flange back Adj.
Fixed data-1
Flange back Adj.
2. 6F Page Table
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 6F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 6F
Page Data”.)
6-11
DSC-P92
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
00
33
26
FD
30
0D
25
60
32
9C
80
80
00
00
EF
FF
80
80
00
00
EF
FF
00
00
00
80
2A
38
5F
A0
05
F4
7C
A8
0F
02
7F
99
7B
A8
00
F4
81
B9
7A
43
01
23
7A
10
6B
0F
F6
0F
AWB 3200K standard data input
AWB 5200K standard data input
Color reproduction adj.
AWB 3200K standard data input
AWB 5800K standard data input
AWB 3200K standard data input
AWB 5800K standard data input
AWB 3200K standard data input
Fixed data-1
Strobe adj.
Mechanical shutter adj.
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54 to 5F
60
61
62
63
64
65
66
67
68 to 6A
6B
6C
6D
6E to 6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
30
FE
6D
FF
00
00
43
7A
1D
5C
41
92
1E
BF
D5
E1
00
00
E7
03
D5
33
00
00
E7
03
00
00
Flange back Adj.
Fixed data-1
F No. standard data input
Light value adj.
Fixed data-1
F No. standard data input/
Mechanical shutter adj.
Fixed data-1
AWB 3200K standard data input
Address
Remark
Initial value
Address
Remark
Initial value
Address
Remark
Initial value
Address
Remark
Initial value
6F page
Page of 44
Display

Click on the first or last page to see other DSC-P92 (serv.man4) service manuals if exist.