Sony DSC-P73 (serv.man11) Service Manual ▷ View online
Auto-ADJ
SERVICE MANUAL
Ver 1.1 2004.05
DSC-P73
Sony EMCS Co.
9-876-733-91
2004E0500-1
© 2004. 5
Published by DI Technical Support Section
CORRECTION-1
We will inform you that there are printing errors
in the service manual previously issued.
• Correction of the data save method
&
: Points added portion.
-
: Points changed portion.
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS
1-1-4.
Using Method of SEUS
(Service Manual Page 6-7)
2.
Operation
• Data saving
To write the all changed data to the nonvolatile memory, click
[Save]
on the SEUS screen and wait for more than 3 sec.
1-1-5.
Precaution on Use of SEUS
(Service Manual Page 6-7)
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Page Edit]
on the SEUS screen to display the SEUS
PAGE EDIT screen.
3) Click
[File]
and load the data from PC.
4) Click
[Write]
on the SEUS PAGE EDIT screen.
5) Click
[Close]
to close the SEUS PAGE EDIT screen.
6) Click
[Save]
on the SEUS screen.
7) Wait for more than 3 sec.
8) Select page: 80, address: 30, and check that the data is “00”.
9) Select page: 00, address: 01 and set data: 00.
8) Select page: 80, address: 30, and check that the data is “00”.
9) Select page: 00, address: 01 and set data: 00.
]
_
;
— 2 —
DSC-P73
&
: Points added parts.
-
: Points changed portion.
1-7.
INITIALIZATION OF DATA
(Service Manual Page 6-22)
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Sector Write]
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “06”.
4) Click
4) Click
[All]
of the ALL SELECT buttons to select all pages. (Fig.
6-1-50 A)
5) Click
[Write]
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click
7) Click
[Close]
to close the SEUS SECTOR WRITE screen.
8) Select page: 8E, address: 00 and set data: 20.
9) Click
9) Click
[Save]
on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
want to initialize will be initialized.
Note 1:
If the 6E or 6F page data have been initialized, the
following adjustment needs to be performed again.
1) Camera system adjustments
following adjustment needs to be performed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Sector Write]
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “06”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-50
4) Click “All” of the option buttons of target page. (Fig. 6-1-50
B
)
5) Click
[Write]
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click
7) Click
[Close]
to close the SEUS SECTOR WRITE screen.
8) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
9) Click
[Save]
on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
+
=
+
=
6-2. SERVICE MODE
1.
Setting the Test Mode
(Service Manual Page 6-23)
• After completing adjustments/repairs, release the data setting.
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 23, and set data: 80.
3) Save the data.
4) Wait for more than 3 sec.
5) Select page: 80, address: 30, and check that the data is “00”.
6) Select page: 00, address: 01, and set data: 00.
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 23, and set data: 80.
3) Save the data.
4) Wait for more than 3 sec.
5) Select page: 80, address: 30, and check that the data is “00”.
6) Select page: 00, address: 01, and set data: 00.
_
;
Display