Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p32-sm4.pdf
Date

Sony DSC-P32 (serv.man4) Service Manual ▷ View online

6-5
DSC-P32
Memory stick
Personal computer
(with two USB ports)
AC IN
DC IN
USB
USB1
USB2
HASP key
AC power
adaptor
Fig. 6-1-4.
[CONNECTION OF EQUIPMENT]
6-6
DSC-P32
1-1-4.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform
adjustments.
SETUP settings
USB connect (SETUP2) ........................................ NORMAL
MENU settings
Camera ......................................................................... AUTO
Switch settings
1.
Mode dial ........................................................... STILL ( 
 )
2.
IMAGE SIZE ................................................................. 3.1M
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.6-1-5.
H
A=
C=D
A
A
B
C
D
Enlargement
V
Picture frame
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Video terminal
output waveform
Fig. b 
Fig. a
B
2
LCD screen or under scan 
monitor TV picture
Color bar chart (Color reproduction adjustment frame)
Adjust the camera position and direction to
obtain the output waveform shown in Fig. a
and the LCD screen or the monitor TV
display shown in Fig. b.
3. Subjects
1)
Color bar chart (Standard picture frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-5. (Standard picture
frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
6-7
DSC-P32
4. Preparing the Flash Adjustment Box
A dark room is required to provide an accurate strobe adjustment.
If it is not available, prepare the flash adjustment box as given below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2 sheets)
400 mm
woody board B (2 sheets)
370 mm
woody board C (1 sheet)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper side
of woody board A, B and C are internal. (Fig. 6-1-7.)
Fig. 6-1-6.
woody board A
woody board B
woody board B
woody board C
woody board A
Fig. 6-1-7.
6-8
DSC-P32
COVER
COVER
1-2.
INITIALIZATION OF 0E, 2F, 4F, 6F PAGE
DATA
1-2-1.
INITIALIZATION OF 2F PAGE DATA
1. Initializing the 2F Page Data
Note:
If the 2F page data has been initialized, the following adjustments
need to be performed again.
1)
Battery end adjustments
Adjusting page
2F
Adjusting Address
00 to 7F
Initializing Method:
1)
Select page:00, address:01, and set data:01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
“2F”.
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input “04” and click [OK] to read the preset data.
6)
On the SEUS PAGE EDIT screen, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Note:
New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8)
Click [Write] to write the initializing data to the EEPROM of
the camera.
9)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 2F Page data
Order Page Address Data
Procedure
1
20
00
29
Write the data.
2
20
01
29
Write the data.
3
Check “Receive Paket Error” is
displayed on the SEUS screen.
4
Turn on the power.
5
Click [Connect] on the SEUS
screen.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 20
21
22 to 49
4A
4B
4C
4D
4E
4F to 7F
00
4E
57
5F
63
63
Test mode
Fixed data-1
Battery end adj.
Fixed data-1
2. 2F Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 2F Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 2F Page
Data”.)
Table. 6-1-2.
Page of 43
Display