DOWNLOAD Sony DSC-P32 (serv.man4) Service Manual ↓ Size: 676.59 KB | Pages: 43 in PDF or view online for FREE

Model
DSC-P32 (serv.man4)
Pages
43
Size
676.59 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p32-sm4.pdf
Date

Sony DSC-P32 (serv.man4) Service Manual ▷ View online

6-15
DSC-P32
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
00
01
01
Set the data.
3
60
01
13
Write the data.
4
60
01
27
Write the data.
5
Wait until the movement of the
lens stops.
6
60
02
Read the data, and check it is “01”.
(Note3)
7
6F
3E
Read the data, and check it
satisfies the specified value 1.
8
6F
24
Read the data, and check it
satisfies the specified value 2.
Note3:
The adjustment data will be automatically input to page:6F, address:
18 to 3E
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
Click [Disconnect].
3
Tuen off the power turn on again.
4
Perform “Flange Back Check”.
5
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
3. Flange Back Adjustment
 (Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
STILL ( 
 )
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Data of page: 6F, address: 24, 3E
Measuring Instrument
Adjustment Page
6F
Adjustment Address
18 to 3E
Specified value1
00
Specified value2
0A to 40
Note1:
Dark siemens star chart.
Note2:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that the center of the siemens star chart and center of
the exposure screen coincide.
Specified voltage:
The specified voltage varies according to the minipattern box, so
adjust the power supply output voltage to the specified voltage
written on the sheet which is supplied with the minipattern box.
Minipattern box
Below 3 cm
Camera
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Fig.6-1-9.
6-16
DSC-P32
4. Flange Back Check
Mode
STILL ( 
 )
Subject
Siemens star
(50cm from the front of the lens)
(Luminance : approx. 300 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
The lens is focused.
Switch setting:
CAMERA setting (Menu setting) ................................ AUTO
Checking method:
Order Page Address Data
Procedure
1
Place the siemens star 50cm from
the front of the lens.
2
60
90
00
Write the data.
3
60
91
00
Write the data.
4
60
92
00
Write the data.
5
60
93
B0
Write the data.
6
60
01
79
Write the data.
7
Wait until the movement of the lens
stops.
8
60
07
Read the data, and check it is “01”.
9
Observe the TV monitor and
check that the lens is focused.
10
60
01
00
Write the data.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
60
90
00
Write the data.
3
60
91
00
Write the data.
4
60
92
00
Write the data.
5
60
93
00
Write the data.
6-17
DSC-P32
5. Picture Frame Setting
Mode
STILL ( 
 )
Subject
Color bar chart and clear chart
(Standard picture frame)
About 26 cm from the front of the lens
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=C=B/2, E=F
Switch setting:
CAMERA setting (Menu setting) ................................ AUTO
IMAGE SIZE ................................................................. 3.1M
Setting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
2
Shoot the color bar chart.
3
Adjust the direction and distance
between the pattern box and
camera, and set the picture
frame to the specified position.
4
Remove the color bar chart and set
the clear chart.
5
Check that the whole of the
screen is white. If not, adjust the
direction and distance slightly.
6
10
44
Read the data, and this data named
YH.
7
10
45
Read the data, and this data named
YL.
8
60
2C
01
Write the data.
9
Perform the following adjustments.
How to reset the focus when they deviated:
If the zoom and focus deviated due to some reason reset them in the
following method.
Order Page Address Data
Procedure
1
60
2C
01
Write the data.
2
60
90
00
Write the data.
3
60
91
00
Write the data.
4
60
92
YL
Write the data. Note
5
60
93
YH
Write the data. Note
6
60
01
79
Write the data.
7
Wait until the movement of the
lens stops.
8
60
07
Read the data, and check it is “01”.
9
60
01
00
Write the data.
Note:
YH and YL are the data read in the “Setting method”.
Check on an oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
E=F
V
E
F
Color bar chart picture frame
Effective picture frame
A
B
C
B
A
C
A = C =
B
2
6-18
DSC-P32
6. F No. Standard Data Input
Adjusted the dispersion of the iris to every to every F number, and
compensate the exposure.
Mode
STILL ( 
 )
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 6F, address: 6B
Measuring Instrument
Adjustment Page
6F
Adjustment Address
60 to 64, 6B to 6D
Specified value
00
Note1:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame.
If deviated, perform “5. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
60
01
BB
Write the data.
5
Wait for 1 sec.
6
60
02
Red the data, and check it is “01”.
(Note2)
7
6F
6B
Read the data, and check it
satisfies the specified value.
Note2:
The adjustment data will be automatically input to page: 6F,
address: 60 to 64, 6B to 6D.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
7. Mechanical Shutter Adjustment
Adjust the dispersion of the opening/closing time and the closing
loss rate of the mechanical shutter. and compensate the exposure.
Mode
STILL ( 
 )
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 6F, address: 6B
Measuring Instrument
Adjustment Page
6F
Adjustment Address
6B to 6D, B8 to D7
Specified value
00
Note1:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame.
If deviated, perform “5. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
60
01
AD
Write the data.
5
Wait until the movement of the
shutter stops.
6
60
02
Read the data, and check it is “01”.
(Note2)
7
6F
6B
Read the data, and check it
satisfies the specified value.
Note2:
The adjustment data will be automatically input to page: 6F,
address: 6B to 6D, B8 to D7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
Page of 43
Display

Click on the first or last page to see other DSC-P32 (serv.man4) service manuals if exist.