DOWNLOAD Sony DSC-P32 (serv.man3) Service Manual ↓ Size: 3.1 MB | Pages: 127 in PDF or view online for FREE

Model
DSC-P32 (serv.man3)
Pages
127
Size
3.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 1
File
dsc-p32-sm3.pdf
Date

Sony DSC-P32 (serv.man3) Service Manual ▷ View online

14
Preparing 
batteries
Use the following batteries in this camera.
Acceptable batteries
HR 15/51:HR6 (size AA) Nickel-Metal 
Hydride batteries (2) 
NH-AA-DA (2) (supplied)
NH-AA-2DA twin-pack (not supplied)
R6 (size AA) alkaline batteries (2)
Batteries that cannot be used
Manganese batteries, lithium batteries, ni-
cad batteries
If you use the batteries described above, we 
cannot guarantee full performance of the 
camera by property of the batteries, such as 
brownout of the batteries.
The battery remaining indicator does not 
display the correct information.
When alkaline batteries are used, take note of 
the following information.
There is a big difference in the performance 
of batteries of different types and of batteries 
made by different manufacturers. This is 
especially true in low temperatures, where 
some batteries are noticeably weaker.
You may not be able to shoot in temperatures 
below +5°C (41°F).
The battery remaining indicator may not 
display the correct information.
Charging the batteries
,
Insert Nickel-Metal Hydride 
batteries into the battery 
charger (supplied) with the 
correct polarity +/
.
You cannot charge alkaline batteries using the 
battery charger.
Be sure to charge the Nickel-Metal Hydride 
batteries supplied with your camera before 
using them.
Connect the battery charger to an easily 
accessible wall outlet (wall socket) close by.
1
,
Connect the battery charger to 
a wall outlet (wall socket) using 
the power cord (mains lead).
Charging starts, and the CHARGE lamp 
lights. When the CHARGE lamp goes out, 
charging is finished.
For details on the battery charger, see page 
page 111.
When charging is finished, disconnect the 
power cord (mains lead) from the wall outlet 
(wall socket), and remove the Nickel-Metal 
Hydride batteries from the battery charger.
Even if the CHARGE lamp is not lit, the set is 
not disconnected from the AC power source 
(mains) as long as it is connected to the wall 
outlet (wall socket). If some trouble occurs 
while using the battery charger, immediately 
shut off the power by disconnecting the plug 
from the wall outlet (wall socket).
2
CHARGE
 lamp
Power cord 
(mains lead)
to a wall outlet 
(wall socket)
Getting started
15
G
e
tti
n
g
 s
ta
rte
d
Charging time
This represents the time required to charge fully 
depleted Nickel-Metal Hydride batteries using 
the supplied battery charger in an environment 
where the ambient temperature is 25°C (77°F).
Charging is complete in approximately six 
hours. The CHARGE lamp may remain lit 
longer than six hours, but this is not a 
malfunction.
If you use the BC-CSQ2 battery charger 
supplied with the STAMINA “Super Quick 
charge” kit (not supplied), the batteries will 
charge faster.
Charging time
When charging two Nickel-Metal Hydride 
batteries: Approximately 2 hours 30 minutes
When charging four Nickel-Metal Hydride 
batteries: Approximately 5 hours
Notes on the Nickel-Metal 
Hydride batteries
If the poles of the Nickel-Metal Hydride 
batteries are dirty, the batteries may not charge 
properly. Occasionally clean the poles of the 
batteries and the terminals of the charger by 
wiping them with a dry cloth.
When transporting the Nickel-Metal Hydride 
batteries, be sure to use the battery case 
(supplied). If the +/- metal terminals are 
shorted, there is a possibility of danger from 
excessive heat or fire.
At the time of purchase, or when the Nickel-
Metal Hydride batteries have not been used for 
a long time, they may not fully charge. This is 
typical of this type of battery, and is not a 
malfunction. If this happens, repeatedly using 
up the battery fully, and then recharging it, 
should correct the problem.
Even when Nickel-Metal Hydride batteries are 
not being used they loose their charge naturally 
over time. It is recommended that you recharge 
the batteries just before using them.
If you recharge Nickel-Metal Hydride batteries 
before fully using up the existing charge, the 
so-called memory effect* can occur, and the 
low battery warning will be triggered sooner 
than expected. Charging the battery after fully 
depleting the existing charge should correct the 
problem.
*
The “memory effect” – the situation in which a 
battery temporarily accepts a less than full 
charge.
To use up the batteries completely, put the 
camera in the slide show mode (page 63) and 
leave it that way until the batteries are used up.
Do not peel off the external seals or damage the 
batteries. Never use batteries from which the 
seals have been partially or completely 
removed, or batteries that have been split in any 
way. These may cause leakage, explosion, or 
heat-up of the battery, and personal scald or 
injury may be caused. These may cause a 
malfunction of the battery charger.
Nickel-Metal Hydride 
battery
Charging time
NH-AA-DA × 2 
(supplied)
Approx. 6 hours
16
Inserting the batteries
,
Open the battery cover.
Slide it in the direction of the arrow with the 
OPEN button pressed, and it opens out.
,
Insert the batteries.
Match the +/
− poles of the batteries to the +/
− marks inside the battery case.
Occasionally clean the poles of the batteries 
and the terminals of the battery cover by wiping 
them with a dry cloth. If the poles of the 
batteries or the terminals become covered with 
a film of dirt or oil from the skin, the operating 
time of the camera can be greatly reduced.
,
Close the battery cover.
Close the battery cover while holding the 
batteries in. The cover is closed when it 
clicks.
To remove the batteries
Stand the camera on end, open the battery 
cover upward, then remove the batteries.
Make sure you do not drop the batteries when 
opening or closing the battery cover.
1
1
2
2
3
1
2
17
G
e
tti
n
g
 s
ta
rte
d
Battery remaining indicator 
(When using the Nickel-Metal 
Hydride batteries)
As the battery power decreases with use, the 
battery remaining indicator displays the 
amount of power remaining using the 
following symbols.
If the LCD screen is off, press 
 to turn it 
on.
Based on the conditions under which the 
camera is being used and the state of the 
charge, or on the environment, this information 
may not be correctly indicated.
When the AC Adaptor (not supplied) is being 
used, the remaining battery information is not 
displayed.
The Power Save function
When the Power Save function is set to On, 
you can shoot for a longer period of time.
Turn the mode selector to SET UP, and set 
[Power Save] in Setup 1 to [On]. The 
factory setting of the camera is set to [On] 
(page 107).
We recommend that you set [Power Save] 
to [On] when using alkaline batteries.
When the Power Save function is On
In shooting still images, the focus only focuses 
when the shutter is pushed down halfway.
While charging the flash, the   lamp flashes 
and the LCD screen is turned off. After the 
flash is completely charged, the LCD screen 
turns on.
Battery life and the number of 
images that can be recorded/
played back
The tables show approximate guidelines for the 
length of time the camera can be used when you 
shoot in Normal mode in an environment where 
the ambient temperature is 25°C (77°F), and the 
batteries are fully charged. The guidelines for the 
number of images that can be recorded or played 
back allow for changing the supplied “Memory 
Stick” as necessary. Actual results may differ 
slightly from these, depending on the conditions 
of use.
Shooting still images
Under the average conditions
1)
Battery 
remaining 
indicator
Battery remaining 
guidelines 
(A full charge is 100%)
Sufficient power remaining
Battery half full
Battery low, recording/
playback will stop soon.
Change the batteries for fully 
charged ones, or charge these 
batteries. (The warning 
indicator flashes.)
Image 
size
NH-AA-DA (2) (supplied)
LCD 
screen
No. of 
images
Battery 
life (min.)
DSC-P72
3.1M
On
Approx. 300 Approx. 150
Off
Approx. 500 Approx. 250
VGA
On
Approx. 300 Approx. 150
Off
Approx. 500 Approx. 250
DSC-P32
3.1M
On
Approx. 320 Approx. 160
Off
Approx. 540 Approx. 270
VGA
On
Approx. 320 Approx. 160
Off
Approx. 540 Approx. 270
Page of 127
Display