Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p150-sm4.pdf
Date

Sony DSC-P150 (serv.man4) Service Manual ▷ View online

6-19
DSC-P150
6.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the Color Shading Adjustment Program
(P150ColorShade.exe).
2) Click the 
[Connect]
  button to set the camera to the adjust-
ment mode.
Fig. 6-1-35
3) Adjust the mode dial of the camera to “P” and set MACRO
mode. Shoot the 9 colors chart with the zoom at WIDE end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the 
[AWB 3200K-5800K Standard Data Input]
 button.
Fig. 6-1-36
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-37
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-38
7) Upon successful completion of the adjustment, the following
message is displayed. Click the 
[OK]
 button.
Fig. 6-1-39
6-20
DSC-P150
6) A picture captured by the camera is displayed on the screen,
and the adjustment is performed.
Fig. 6-1-42
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-43
7) Upon successful completion of the adjustment, the following
message is displayed. Click the 
[OK]
 button.
Fig. 6-1-44
7.
Color Reproduction Adjustment
[Adjustment method]
1) Start the Color Shading Adjustment Program
(P150ColorShade.exe).
2) Click the 
[Connect]
  button to set the camera to the adjust-
ment mode.
Fig. 6-1-40
3) Adjust the mode dial of the camera to “P” and set MACRO
mode. Shoot the 9 colors chart with the zoom at WIDE end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the 
[Color Reproduction Adjustment]
 button.
Fig. 6-1-41
6-21
DSC-P150
6) A picture captured by the camera is displayed on the screen,
and the checking is performed.
The checking result is displayed on the vector scope screen.
Fig. 6-1-47
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-48
7) Upon successful completion of the checking, the following
message is displayed. Click the 
[OK]
 button.
Fig. 6-1-49
8.
Color Reproduction Check
[Checking method]
1) Start the Color Shading Adjustment Program
(P150ColorShade.exe).
2) Click the 
[Connect]
  button to set the camera to the adjust-
ment mode.
Fig. 6-1-45
3) Adjust the mode dial of the camera to “P” and set MACRO
mode. Shoot the 9 colors chart with the zoom at WIDE end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the 
[Color Reproduction Check]
 button.
Fig. 6-1-46
6-22
DSC-P150
9.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. CCD Linearity Check
4. CCD White Defect Compensation Check
5. CCD Black Defect Compensation Check
6. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 4 Start]
 button.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-24 to
Fig. 6-1-26 (See page 6-16), set the subject and click the 
[OK]
button.
Fig. 6-1-50
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-51
4) Click the 
[OK]
 button, and the items from “3. CCD Linearity
Check” to “6. Release of Data Setting during Camera Adj.”
will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-52
Page of 35
Display

Click on the first or last page to see other DSC-P150 (serv.man4) service manuals if exist.