Sony DSC-N2 (serv.man4) Service Manual ▷ View online
6-29
DSC-N2_ADJ
6-2. SERVICE MODE
1.
Setting the Test Mode
Page 40
Address A1, A3
• Forced CAMERA mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
• Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 07.
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 07.
• Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
• After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
1) Select page: 40, address: A1, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
ues from block (B).
6-30
DSC-N2_ADJ
3.
LED Check
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 40, address: 70, and set data: 01.
3) Select page: 40, address: 98, and Check that the data is “00”.
4) Select page: 8E, address: FE, and set data: 20.
5) Select page: 80, address: 12, and set data: 01.
6) Check that all LED are lit.
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 40, address: 70, and set data: 01.
3) Select page: 40, address: 98, and Check that the data is “00”.
4) Select page: 8E, address: FE, and set data: 20.
5) Select page: 80, address: 12, and set data: 01.
6) Check that all LED are lit.
• SELF TIMER/AF ILLUMINATOR
• MS ACCESS
7) Select page: 80, address: 12, and set data: 00.
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
10) Click [Disconnect] on the SEUS screen.
11) Disconnect the USB cable.
12) Turn off the power.
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
10) Click [Disconnect] on the SEUS screen.
11) Disconnect the USB cable.
12) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00
When data = 01
When data = 02
Shutter button
(XAE LOCK SW)
(XAE LOCK SW)
OFF
ON
ON
RL-062 flexible S002
Shutter button
(XSHUTTER SW)
(XSHUTTER SW)
OFF
OFF
ON
RL-062 flexible S002
6-31
DSC-N2_ADJ
6.
Mode Switch Check
Page 20
Addresses A3
Using method:
1) Select page: 20, addresses: A3.
2) By discriminating the read data, the state of the mode switch can be discriminated.
1) Select page: 20, addresses: A3.
2) By discriminating the read data, the state of the mode switch can be discriminated.
Address
Data
00 to 0C
0D to 28
29 to 4A
4B to 77
78 to FF
A0
ZOOM T
ZOOM W
TOUCH PANEL
SCREEN STATUS
(KEY AD0)
(SW-460 flexible) (SW-460 flexible) (SW-460 flexible) (SW-460 flexible)
No key input
(IC301 AA13)
(S001)
(S002)
(S003)
(S004)
5.
Switch Check (2)
Page 20
Addresses A0
Using method:
1) Select page: 20, addresses: A0.
2) By discriminating the read data, the pressed key can be dis-
1) Select page: 20, addresses: A0.
2) By discriminating the read data, the pressed key can be dis-
criminated.
7.
Self Diagnosis Code
6-31
Note: After repair, be sure to execute the “Initialize” of the setup screen.
Address
Data
00 to 4A
4B to 77
78 to 9B
9C to B4
B5 to FF
A3
MOVIE
PLAY
CAMERA
(MODE DIAL0)
–
(SW-460 flexible) (SW-460 flexible)
–
(SW-460 flexible)
(IC301 AB14)
(S005)
(S005)
(S005)
Display Code
C:32:ss
C:13:ss
Countermeasure
Turn the power off and on again.
Format the “Memory Stick” or
internal memory.
internal memory.
Cause
Trouble with hardware.
“Memory Stick” or internal memory is
unformatted.
unformatted.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
E:61:ss
E:91:ss
Insert a new “Memory Stick”.
“Memory Stick” is broken.
Turn the power off and on again.
Trouble with internal memory.
INTERNAL MEMORY ERROR
Checking of lens drive circuit.
When failed in the focus and zoom
initialization.
initialization.
—
Checking of flash unit or replacement
of flash unit. (Note)
of flash unit. (Note)
Abnormality when flash is being
charged.
charged.
6-31E
Revision History
Reverse
DSC-N2_ADJ
Ver.
1.0
1.1
1.2
1.3
Date
2006.09
2007.02
2007.02
2007.08
History
Official Release
Supplement-1
(S1 PV06-161)
Correction-1
(C1)
(C1)
Supplement-2
(S2 DI07-045)
Contents
—
• Addition of Brazilian Model
• Change of Automatic Adjustment Program
• Change of Automatic Adjustment Program
• Correction of the Table 6-1-1
S.M. correction:
S.M. correction:
Page 6-5
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program
has been changed from Ver_1.1r02 into
Ver_1.3r03.
has been changed from Ver_1.1r02 into
Ver_1.3r03.
• Addition of “DESTINATION DATA
WRITE”
S.M. Rev.
issued
—
Yes
Yes
Yes
985214354.pdf
Click on the first or last page to see other DSC-N2 (serv.man4) service manuals if exist.