DOWNLOAD Sony DSC-N2 (serv.man4) Service Manual ↓ Size: 589.38 KB | Pages: 34 in PDF or view online for FREE

Model
DSC-N2 (serv.man4)
Pages
34
Size
589.38 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-n2-sm4.pdf
Date

Sony DSC-N2 (serv.man4) Service Manual ▷ View online

6-24
DSC-N2_ADJ
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
Fig. 6-1-49
SEUS operation screen
Fig. 6-1-50
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-51
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj.”.
3) Upon successful completion of the “1. Data Setting during LCD
Adj.”, the following message is displayed during execution in
“2. V-COM Adj.”. On the SEUS screen, operate the UP/DOWN
key so that the brightness of portions A and B on the LCD
panel is equal. After the adjustment, click the [OK] button.
Fig. 6-1-47
4) Upon completion of “2. V-COM Adj.”, the following screen is
displayed during the execution of “3. White Balance Adj.”.
Check that the LCD screen is not colored. If colored, using the
[Up]/[Down] button on the screen, adjust so that the LCD screen
is not colored. After the adjustment, click the [End] button in
the screen.
Fig. 6-1-48
5) If the [End] button is clicked, “4. Release of Data Setting dur-
ing LCD Adj.” will be executed.
UP/DOWN key
A
B
6-25
DSC-N2_ADJ
1-6.
CONTROL  SYSTEM  ADJUSTMENTS
1-6-1.
Function of Each Button on Control System
Adjustment Screen
Click the [CONTROL SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CONTROL SYSTEM ADJUSTMENT”
screen in Fig. 6-1-52 will appear.
Fig. 6-1-52
1
[To Menu] button
The Main Menu screen comes back.
2
[Start] button
“Touch Panel Adjustment” starts.
3
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
1-6-2.
Adjustment Items of Control System Adjust-
ment
The adjustment items of control system adjustment are as listed in
Table 6-1-5. The Automatic Adjustment Program executes the ad-
justment items if the Touch Panel Adjustment Start button is
clicked.
Adjustment
Signal
Page
Address
Touch Panel adj.
Arbitrary
4F
8A to 8D
Table 6-1-5
1-6-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Control Adj.
2. Touch Panel Adj.
3. System Reset
[Adjusting method]
1) Click the [Start] button of Touch Panel Adjustment.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Control Adj.”.
3) Upon successful completion of “1. Data Setting during Con-
trol Adj.”, “2. Touch Panel Adj.” will be executed. The follow-
ing message is displayed, and then adjust the LCD screen in
accordance with the instructions given on screen. After the
adjustment, click the [OK] button in the message window.
Fig. 6-1-53
4) If the [OK]  button is clicked, “3. System Reset” will be ex-
ecuted.
5) Upon successful completion of all items of the Touch Panel
Adjustment, the following message is displayed. Click the [OK]
button.
Fig. 6-1-54
3
2
1
6-26
DSC-N2_ADJ
1-7.
ERROR
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-7-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error
Fig. 6-1-55
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SEUS is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SEUS and click the [Connect] to check
that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-56
Symptom
The camera is not ready for adjustment.
Cause
• Data error exists in the camera.
Remedy
• Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-57
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-58
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-27
DSC-N2_ADJ
5.
Data Save Error
Fig. 6-1-59
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
• Data writing to the flash memory failed.
• Connection is faulty.
• Power supply is not installed correctly.
Remedy
• On the SEUS Operation screen, [Set] the data
to the pages and addresses displayed in the
message, and [Save] them. (Cancel manually
the data setting during adjustment.)
• Check the connection.
• Install the power supply correctly.
1-7-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1: With this data left in the camera, the camera will not op-
erate normally.
In this case, the [Release Data Setting] button is displayed in “red”
on the screen as shown in Fig. 6-1-60, 61 and 62. Click the
[Release Data Setting] button to cancel the data setting. When the
data setting is cancelled, the button color becomes “white”.
Note 2: When “Data Save Error” occurred, the [Release Data Set-
ting] button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Video System Adjustment screen
Fig. 6-1-60
Camera System Adjustment screen
Fig. 6-1-61
LCD System Adjustment screen
Fig. 6-1-62
How to cancel the 
data setting during 
adjustment is 
display here.
Page of 34
Display

Click on the first or last page to see other DSC-N2 (serv.man4) service manuals if exist.