DOWNLOAD Sony DSC-HX7 / DSC-HX7V (serv.man2) Service Manual ↓ Size: 5.21 MB | Pages: 23 in PDF or view online for FREE

Model
DSC-HX7 DSC-HX7V (serv.man2)
Pages
23
Size
5.21 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-hx7-dsc-hx7v-sm2.pdf
Date

Sony DSC-HX7 / DSC-HX7V (serv.man2) Service Manual ▷ View online

DSC-HX7/HX7V_L2
1-2
– ENGLISH –
1-3.  HOW TO WRITE DATA TO INTERNAL MEMORY
Usually, the camera has been set so as to disable the data writing from the PC to the internal memory of the camera.
This setting must be changed temporarily when the data is to be written to the internal memory such as a case after the board replacement.
To change settings is enabled with using the writing enabler tool (Write Enable Tool) on the Adjust Manual is activating from the Adjust Station.
Data writing method
1)  Start the Adjust Manual from the Adjust Station.
2) Click 
 (Write Enable Tool) button.
3)  Click “Activate Write Enable Mode” button.
4)  Upon completion of the setting change, the following message will be displayed.
5)  Return the driver to the original one, and connect the PC to the camera (USB mode: Mass Storage).
6)  Write the data read out into the PC to the internal memory of the camera.
7)  Disconnect the PC from the camera, and turn off the camera.
Note: By turning off the camera, the write enable setting is reset.
1-4. SELF-DIAGNOSIS FUNCTION
1-4-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis func-
tion starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction 
manual.
1-4-2. Self-diagnosis Display
When problems occur while the unit is operating, the LCD screen shows 
a 4-digit display consisting of an alphabet and numbers, which blinks at 
3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in 
which the problem occurred, and “detailed code” of the problem.
0 0
3 2
C
Repaired by:
Refer to “1-4-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
0 0
3 2
C
Repaired by:
Refer to “1-4-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
DSC-HX7/HX7V_L2
1-3
– ENGLISH –
1-5.  PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed 
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be on the HOME screen.
Method for Initializing the Flash Error Code
Reset Flash Error using the Flash Error Repair Tool Ver_[].[].exe.
1-4-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a me-
dia error.
Turn the power off and on again.
The internal memory has experienced a for-
mat error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the 
memory card.
Turn the power off and on again, or taking out and inserting the memory 
card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, 
check the focus reset sensor of lens block (pin 6 of CN401 on the 
SY-283 board). If it is OK, check the focus motor drive IC (IC401 on 
the SY-283 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset 
sensor of lens block (pin 0 of CN401 on the SY-283 board) when 
zooming is performed when the zoom button is operated. If it is OK, 
check the zoom motor drive IC (IC401 on the SY-283 board).
E
6
2
0
2
Abnormality of IC for steadyshot.
Check of the IC for steadyshot (IC401 on the SY-283 board).
E
6
2
1
0
Lens initializing failure.
Check of the IC for steadyshot (IC401 on the SY-283 board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin rk, 
t;
 of CN401 on the SY-283 board). If it is OK, check PITCH angular 
velocity sensor (SE401 on the SY-283 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin ef, 
eh
 of CN401 on the SY-283 board). If it is OK, check YAW angular 
velocity sensor (SE401 on the SY-283 board) peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin qs of 
CN401 on the SY-283 board).
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note)
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC201 on the SY-283 board).
E
9
5
0
0
GPS hardware error
Check whether the FP-1395 flexible board of connected between AT-
042 board and RL-108 board or RL-099 flexible board of connected 
between SY-283 board and RL-108 board is broken, and check whether 
it is inserted imperfectly.
If there is no problem the coaxial cable or flexible board, inspect or 
replacement of the AT-042 or RL-108 board.
Note: After repair, be sure to perform “1-5. PROCESS AFTER FIXING FLASH ERROR”.
The changed portions from
Ver. 1.1 are shown in blue.
Ver. 1.2 2011.07
DSC-HX7/HX7V_L2
1-4
1-1.  SY-283基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
リストアデータ
補修用基板と交換する時,交換前の基板よりデータを取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「RESTORE DATA」を実行させてください。
本機で取得されるデータは下記になります。
・ USB SERIAL No.
・ Angular Velocity Sensor sensitivity adjustment
・ AWB standard data input & check, Color reproduction check
Note:交換前の基板よりデータが読み取れない場合は,SY-283基板とレンズを同時に交換する必要があります。
PMB Portableについて
本機の内蔵メモリー内にはPMB Portableが書き込まれています。
補修用SY-283基板は,PMB Portableが書き込まれた状態で供給されます。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB SERIAL No. INPUT」を実行させてください。
角速度センサ
補修用基板と交換する時,角速度センサ(SE401)の感度表示を書き留めてください。
Adjust StationからAdjust Manualを起動させて「Angular velocity sensor sensitivity adj.」を実行させてください。
SY-283 BOARD (SIDE B)
SE401
(PITCH/YAW)
PPP
YYY
PPP: PITCH 感度表示 
YYY: YAW 感度表示 
Note:SY-283基板のSE401感度表示は補修用基板にしか記載されておりません。
– JAPANESE –
1-2.  内蔵メモリーのデータコピーおよび消去方法
内蔵メモリーのデータコピーまたは消去はホーム画面の操作から実行可能です。
(消去する場合は内蔵メモリーの初期化を行います。)
Note1:SY-283基板交換の際は,基板交換前に内蔵メモリーのデータを消去して下さい。
Note2:SY-283基板交換の際は,基板交換後に内蔵メモリーのフォーマットおよび初期化を実行して下さい。
内蔵メモリーのコピー方法
サイバーショットユーザーガイド
コピー
内蔵メモリーに記録した画像を、メモリーカードに一括コピーします。
1. 充分な空き容量のあるメモリーカードを本機に入れる
2. MENU  (設定)
 
(メモリーカードツール)
[コピー]
OK]
 中央の
ご注意
充分に充電したバッテリーをご使用ください。残量の少ないバッテリーを使用して画像ファイルをコピー
すると、バッテリー切れのためデータを転送できなかったり、データを破損するおそれがあります。
画像ごとのコピーはできません。
データをコピーしても、内蔵メモリー内のデータは削除されません。内蔵メモリーの内容を消去するに
は、コピー後にメモリーカードを本体から取りはずし、[内蔵メモリーツール]の[フォーマット]を行ってく
ださい。
データをコピーすると、現在の指定している記録フォルダに一番最後のファイル番号でコピーされます。
【詳細】
 
内蔵メモリー、もしくはメモリーカードのフォーマット方法
サイバーショットユーザーガイド
フォーマット
メモリーカード、または内蔵メモリーをフォーマット(初期化)します。
メモリーカードの動作を安定させるために、メモリーカードを本機ではじめてお使いになる場合には、まず、本
機でフォーマットすることをおすすめします。フォーマットすると、メモリーカードに記録されている全てのデータ
は消去され、元に戻すことはできません。大切なデータはパソコンなどに保存しておいてください。
1. MENU  (設定)
 
(メモリーカードツール)、または
(内蔵メモリーツール)
[フォーマ
ット]
 [
OK] 
 中央の
ご注意
フォーマットすると、プロテクトしてある画像も含めて、すべてのデータが消去され、元に戻せません。
DSC-HX7/HX7V_L2
1-5
– JAPANESE –
1-3.  内蔵メモリーへデータを書き戻す方法
通常は,PCからカメラの内蔵メモリへデータを書き込むことはできない設定になっています。
基板交換後などに,内蔵メモリへデータを書き戻す場合には,この設定を一時的に変更する必要があります。
設定の変更は,Adjust StationからAdjust Manualを起動させて書き込み許可ツール(Write Enable Tool)を使用します。
書き戻し方法 
1)  Adjust StationからAdjust Manualを起動する。
2) 
 (Write Enable Tool)ボタンをクリックする。
3) 
Activate Write Enable Mode ボタンをクリックする。
4)   設定の変更が終了すると,次のメッセージが表示されますので OK ボタンをクリックする。
5)  ドライバを元に戻して、カメラとPCをマスストレージ接続する。
6)  PCに読み出しておいたデータをカメラの内蔵メモリに書き込む。
7)  カメラとPCの接続を解除し,カメラの電源をOFFにする。
注意: カメラの電源をOFFにすることにより,書き込み許可の設定が解除されます。
1-4.  自己診断機能
1-4-1. 自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,LCD
画面に,どう処置したらよいか判断できる表示を行います。自
己診断機能については取扱説明書にも掲載されて
います。
1-4-2. 自己診断表示
本機の動作に不具合が生じたとき,LCD画面にアルファベッ
トと4桁の数字が表示され,3.2Hzで点滅します。この5文字の
表示によって対応者分類および不具合の生じたブロックの分
類,不具合の詳細コードを示します。
0 0
C
2
3
対応者分類 
「1-4-3. 自己診断コード表」を参照 
対応方法の違いにより分類 
例 
 
 
 メモリーカードをフォーマットする 
3
1
32 ・・ ・電源を入れ直す 
ブロック分類 
詳細コード 
3.2 Hz点滅 
C  :お客さま自身で対応 
E  :サービスエンジニア 
 
で対応 
LCD画面 
0 0
C
2
3
対応者分類 
「1-4-3. 自己診断コード表」を参照 
対応方法の違いにより分類 
例 
 
 
 メモリーカードをフォーマットする 
3
1
32 ・・ ・電源を入れ直す 
ブロック分類 
詳細コード 
3.2 Hz点滅 
C  :お客さま自身で対応 
E  :サービスエンジニア 
 
で対応 
LCD画面 
Page of 23
Display

Click on the first or last page to see other DSC-HX7 / DSC-HX7V (serv.man2) service manuals if exist.