DOWNLOAD Sony DSC-HX300 (serv.man2) Service Manual ↓ Size: 8.46 MB | Pages: 31 in PDF or view online for FREE

Model
DSC-HX300 (serv.man2)
Pages
31
Size
8.46 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-hx300-sm2.pdf
Date

Sony DSC-HX300 (serv.man2) Service Manual ▷ View online

DSC-HX300_L2
1-3
– ENGLISH –
1-3.  METHOD FOR COPYING OR ERASING THE DATA IN INTERNAL MEMORY
The data can be copied/erased by the operations on the MENU. (When erasing the data, execute formatting the internal memory.)
Note 1:When replacing the SY-1016 board, erase the data in internal memory of the board before replacement.
Note 2:When replacing the SY-1016 board, execute formatting and initialize the internal memory after replacement.
Method for Copying the Data in Internal Memory
Copy
Copies all images in the internal memory to a memory card.
1.  Insert a memory card with sufficient free capacity into the camera.
2.  MENU 
 
 (Settings) 
 
 (Memory Card Tool) 
 [Copy] 
 [OK] 
 
Notes
Use a fully charged battery pack. If you attempt to copy image files using a battery pack with little
remaining charge, the battery pack may run out, causing copying to fail or possibly corrupting the
data.
Images cannot be copied individually.
The original images in the internal memory are retained even after copying. To delete the contents
of the internal memory, remove the memory card after copying, then format the internal memory
([Format] in [Internal Memory Tool]).
The data will be copied to the recording folder that is currently being used, with a number one
higher than the largest data number in that folder.
Method for Formatting the Internal Memory or Memory Card media
Format
Formats the memory card or the internal memory.
When you use a memory card with this camera for the first time, it is recommended to format the card
using the camera for stable performance of the memory card before shooting. Note that formatting
permanently erases all data on the memory card, and is unrecoverable. Save precious data on a
computer, etc.
1.  MENU 
 
 (Settings) 
 
 (Memory Card Tool) or 
 (Internal Memory Tool) 
 [Format] 
 [OK] 
 
Notes
Note that formatting permanently erases all data including even protected images.
1-4.  HOW TO WRITE DATA TO INTERNAL MEMORY
Usually, the camera has been set so as to disable the data writing from the PC to the internal memory of the camera.
This setting must be changed temporarily when the data is to be written to the internal memory such as a case after the board replacement.
To change settings is enabled with using the writing enabler tool (Write Enable Tool) on the Adjust Manual is activating from the Adjust Station.
Data writing method
1)  Start the Adjust Manual from the Adjust Station.
2) Click 
 (Write Enable Tool) button.
3)  Click “Activate Write Enable Mode” button.
 
4)  Upon completion of the setting change, the following message will be displayed.
 
5)  Return the driver to the original one, and connect the PC to the camera (USB mode: Mass Storage).
6)  Write the data read out into the PC to the internal memory of the camera.
7)  Disconnect the PC from the camera, and turn off the camera.
Note: By turning off the camera, the write enable setting is reset.
DSC-HX300_L2
1-4
– ENGLISH –
1-5. SELF-DIAGNOSIS FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis func-
tion starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction 
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the LCD screen shows 
a 4-digit display consisting of an alphabet and numbers, which blinks at 
3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in 
which the problem occurred, and “detailed code” of the problem.
0 0
3 2
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
1-5-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a me-
dia error.
Turn the power off and on again.
The internal memory has experienced a for-
mat error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the 
memory card.
Turn the power off and on again, or taking out and inserting the memory 
card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, 
check the focus reset sensor of lens block (pin qh, qk of CN402 on the 
SY-1016 board). If it is OK, check the focus motor drive IC (IC403 
on the SY-1016 board).
E
4
1
0
0
Abnormality of network control.
Turn power off and turn power on again.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset 
sensor of lens block (pin qf of CN402 on the SY-1016 board) when 
zooming is performed when the zoom button is operated. If it is OK, 
check the zoom motor drive IC (IC403 on the SY-1016 board).
E
6
1
3
0
Reset position detection error on the stepper
iris initializing
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Check or replacement of the IC for steadyshot (IC403 on the SY-1016 
board).
E
6
2
1
0
Lens initializing failure.
Check or replacement of the IC for steadyshot (IC403 on the SY-1016 
board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin wj, 
wk
 of CN402 on the SY-1016 board). If it is OK, check PITCH angular 
velocity sensor (SE401 on the SY-1016 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin e;, 
ea
 of CN402 on the SY-1016 board). If it is OK, check YAW angular 
velocity sensor (SE401 on the SY-1016 board) peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the temp sensor of optical image stabilizer (pin qs of CN402 
on the SY-1016 board).
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note 1)
E
9
2
0
0
Battery / Dry cell distinction defect
Turn power off and turn power on again.
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC201 on the SY-1016 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
5
0
1
Acceleration sensor hardware error 
Turn power off and turn power on again.
E
9
5
0
2
Electronic compass hardware error 
(GPS hardware error)
Turn power off and turn power on again.
Note 1: After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
Note 2: Functions of codes with * mark are not provided in this unit.
*
*
*
*
(                                             )
DSC-HX300_L2
1-5
1-6.  PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed 
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. 
Method for Initializing the Flash Error Code
Reset Flash Error using the Flash Error Repair Tool Ver_[].[].exe.
– ENGLISH –
– JAPANESE –
1-1.  SY-1016基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
リストアデータ
補修用基板と交換する時,交換前の基板よりデータを取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「RESTORE DATA」を実行させてください。
本機で取得されるデータは下記になります。
・ PRODUCT ID & USB SERIAL No.
・ AWB standard data input & check, Color reproduction check
USBシリアルNo.およびプロダクトIDについて
本機はセット固有のID(USBシリアルNo.)と機種固有のID(プロダクトID)を書き込んだ後に出荷されています。
新品の補修用基板にはこれらのIDが書き込まれていないため,基板交換後にIDを入力する必要があります。
補修用基板に交換した後はAdjust StationからAdjust Manualを起動し,「PRODUCT ID & USB SERIAL No. INPUT」を実行させてIDを入
力してください。
Note:  新しくプロダクトIDを入力すると,必ずしも基板交換前のIDと同じIDになるとは限りません。新しいIDと元のIDが違う場合にはお客様がユーザー登録さ
れているIDと相違が出てしまう可能性があります。
角速度センサ
補修用基板と交換する時,角速度センサ(SE401)の感度表示を書き留めてください。
Adjust StationからAdjust Manualを起動させて「Angular velocity sensor sensitivity adj」を実行させてください。
SY-1016 BOARD (SIDE A)
SE401
Y  P
Y P
Type B:
Type A:
P: PITCH
感度表示
Y: YAW
感度表示
Note:SY-1016基板のSE401感度表示は補修用基板にしか記載されておりません。
DSC-HX300_L2
1-6
– JAPANESE –
1-2.  Destination Data ファイルの追加について
Adjust manual に含まれる Destination Data ファイルが古い場合, 
「DESTINATION DATA WRITE」 が実行できないことがあります。
その場合は,下記の手順を参考にして, TISS ホームページより新しい Destination Data ファイル を入手してください。 
Note 1:  この機種で仕向け設定を行うには,DSC-WX50シリーズの Adjust manual がインストールされている必要があります。
 
 
先に DSC-WX50 シリーズの Adjust manual をインストールしてください。
Note 2:  手順中の画像は実際と異なる場合があります。
1)  使用している Adjust manual の Destination Data ファイルが古い場合, Fig. 1 のようなウインドウが表示される。
 
[OK] ボタンをクリックする。
 
 
 Fig. 
1
2)  Destination Data Write ウインドウが表示される。 
 
 
 
 
Adjust manual の保持している Destination Data ファイル のバージョンを確認する。 
 
 
Destination Ver. ウインドウ
3)  TISSホームページにて,新しい Destination Data ファイルを入手したい機種を検索する。 
 
Destination  Data  ファイルが更新されている場合,「Destination  File  For  機種名 .zip」 という名称のファイルが登録されてい
る。 
 (例) Destination File For DSC-WX50.zip
 また,Remarks欄にはこの Destination Data ファイルが対応するバージョンが記載されています。
 Note: バージョンが更新されていなかった場合は,サービスヘッドクォーターへお問い合わせください。
4)  該当機種の Destination Data ファイルをダウンロードし,解凍する。 
 
5)  Adjust manual の Adjust タブにある,「DESTINATION DATA WRITE」 を実行する。
 
[START] ボタンをクリックする。
 
Page of 31