DOWNLOAD Sony DSC-HX300 (serv.man2) Service Manual ↓ Size: 8.46 MB | Pages: 31 in PDF or view online for FREE

Model
DSC-HX300 (serv.man2)
Pages
31
Size
8.46 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-hx300-sm2.pdf
Date

Sony DSC-HX300 (serv.man2) Service Manual ▷ View online

DSC-HX300_L2
1-10
1-7.  ORNAMENTAL PLATE REPLACING METHOD
Removal
(1)  Pour a solvent such as alcohol from four places A to the tweezers or a needle shown below into a gap of Ornamental Plate.
(2)  Remove the Ornamental Plate.
 
Tweezers
A
A
Ornamental Plate
Solvent
(3)  Remove the three screws to detach the Filter Screw Frame Assy. 
 
Filter Screw Frame Assy
 
Installation
(1)  Match the boss of the Filter Screw Frame Assy with the concave of the 1st Frame Assy, install the Filter Screw Frame Assy, and then tighten three 
screws.
 
Filter Screw Frame Assy
1st Frame Assy
Concave
Boss
(2) Peel off the release paper of the Ornamental Plate and stick the Ornamental Plate matching the boss of the Ornamental Plate with the screw A 
position.
 
Ornamental Plate
Screw A position
Boss
1-8.  2ND ASSY REPLACING METHOD
Removal
(1)  Peel off the Polyester Tape.
(2)  Unsolder the Main Flexible Board and the Shutter Flexible Board.
 
Shutter Flexible Board
Main Flexible Board
Solders
Polyester Tape
(3)  Peel off the Shutter Flexible Board.
 
Adhesive Tape
Shutter Flexible Board
Main Flexible Board
(4)  Disconnect the 5th Assy Flexible Board from the connector on the Main Flexible Board.
 
Main Flexible Board
5th Assy
Flexible Board
DSC-HX300_L2
1-11
(5)  Peel the Main Flexible Board off the Fixed Stationary Tube Assy.
 
Adhesive Tapes
Fixed Stationary Tube Assy
Main Flexible Board
(6)  Remove the three screws to detach the Z Motor.
(7)  Disconnect the Vibration Absorption Flexible Board from the connector on the Main Flexible Board.
(8)  Peel the Main Flexible Board off the Fixed Stationary Tube Assy.
 
Fixed Stationary
Tube Assy
Main Flexible
Board
Vibration Absorption
Flexible Board
Adhesive Tape
Z Motor
(9)  Remove the six screws to detach the Rear Mirror Assy.
 
Rear Mirror Assy
(10)  Turn the Naruto Gear counterclockwise to extend the lens.
(11)  Draw the F Flexible Board and the Vibration Absorption Flexible Board inside the Fixed Stationary Tube Assy.
(12)  Turn the Naruto Gear clockwise to return the lens to the previous position.
 
Naruto Gear
F Flexible Board
Vibration Absorption
Flexible Board
Fixed Stationary
Tube Assy
(13)  Remove the Naruto Gear.
 
Naruto Gear
 
(14)  Remove the Fixed Stationary Tube Assy.
 
Fixed Stationary
Tube Assy
DSC-HX300_L2
1-12
(15)  Turn the Cam Tube in the direction of the arrow to detach the 1st Assy.
 
1st Assy
Cam Tube
(16)  Remove the four screws to detach the Bearing Assy and the Straight Tube Thrust Spring.
 
Bearing Assy
Straight Tube
Thrust Spring
(17)  Remove the 4th Assy.
 
4th Assy
(18)  Fully turn the Shafts Retainer Assy in the direction of arrow.
(19)  Remove the 3rd Assy.
 
Note: When removing the 3rd Assy, hold the bottom of the 2nd Assy to prevent it from falling.
 
3rd Assy
2nd Assy
Shafts Retainer Assy
(20)  Remove the Cam Tube Assy.
 
Cam Tube Assy
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2013.05
DSC-HX300_L2
1-13
(21)  Remove the five screws to detach the Shafts Retainer Assy and the 2nd Assy.
 
2nd Assy,
Shafts Retainer Assy
(22)  Detach the 2nd Assy from the Shafts Retainer Assy.
 
Shafts Retainer Assy
2nd Assy
Installation
(1)  Attach the 2nd Assy to the Shafts Retainer Assy.
 
Shafts Retainer Assy
2nd Assy
(2)  Match the groove with the hole and attach the Straight Tube to the Cam Tube Assy.
Cam Tube Assy
Straight Tube
Match the groove with the hole
Hole
Groove
(3)  Match the boss with the groove, attach the Shafts Retainer Assy and the 2nd Assy to the Straight Tube, and then tighten five screws.
 
2nd Assy,
Shafts Retainer Assy
Straight Tube
Groove
Boss
Page of 31
Display

Click on the first or last page to see other DSC-HX300 (serv.man2) service manuals if exist.