Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h7-dsc-h9-sm5.pdf
Date

Sony DSC-H7 / DSC-H9 (serv.man5) Service Manual ▷ View online

6-19
DSC-H7/H9_ADJ
1-6-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-4. The Automatic Adjustment Program divides the ad-
justment items into seven, camera adjustment 1-6. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note 1:
The Automatic Adjustment Program does not support the “Wide Limit Adjustment”.
Note 2:
Dark Siemens star chart.
Table 6-1-4
Block
Page
Address
Hall Adj.
11
61
0E00 to 0E06
Auto Orientation Adj.
11
61
0E08 to 0E0B
(Note 1)
Wide Limit Adj.
Not required
11
61
0F18, 0F19
CAMERA Adjustment 2
Flange Back Adj.
Siemens star chart with ND filter
for minipattern box (Note 2) or
Flange back adjustment jig
11
61
069C to 069F,
06CC,
06D8 to 06DF,
06E8 to 06EF,
0794 to 079D,
0F1C, 0F1D,
0F20, 0F24,
0F26 to 0F53
CAMERA Adjustment 3
Flange Back Check
Siemens star
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
-
-
-
F No. Compensation
11
61
0A4D to 0A4F,
0ABD to 0ABF,
0ACB
Measure Gain, LV Adj.
11
61
0961 to 0968
Mechanical Shutter Adj.
11
61
0980 to 09AD
AWB 3200K-5800K
Standard Data Input
11
61
0C00 to 0C21,
0C24 to 0C49
AWB 3200K-5800K Check
-
-
-
Color Reproduction
Adj. & Check
11
61
0C50 to 0C57
CCD Linearity Check
-
-
-
CCD White Defect
Compensation Check
11
61
0200 to 02FF,
0F08 to 0F0D,
0F76 to 0F79,
0F7E to 0F83
CCD Black Defect
Compensation Check
11
61
0000 to 00FF,
0F70 to 0F75,
0F7A to 0F7D,
0F84 to 0F87
CAMERA Adjustment 5
Strobe Adj.
Flash adjustment box (50 cm)
11
61
09C0 to 09DD,
0C72 to 0C75
CAMERA Adjustment 6
Auto Focus Illumination Check
Flash adjustment box (50 cm)
11
61
0F10 to 0F15
CAMERA Adjustment 7
Angular Velocity Sensor
Sensitivity Adj.
Not required
11
61
0E10, 0E11
Adjusting Address
Button Name
Adjustment
Subject
Not required
CAMERA Adjustment 1
Clear chart
(Standard picture frame)
CAMERA Adjustment 4
Clear chart
(Standard picture frame)
9 color chart
(Standard picture frame)
6-20
DSC-H7/H9_ADJ
6) If the [OK] button is clicked, “3. Auto Orientation Adj.” and
“4. Release of Data Setting during Camera Adj.” will be ex-
ecuted.
7) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
Processing after Completing Adjustment:
[Checking method]
1) [HOME screen] 
t  [Settings]  t  [Shooting Settings] t
[Shooting Settings 2] 
t Select [Auto Orientation] to “ON”.
2) Shoot with the set in respective positions (a) to (c) shown be-
low.
3) Check the pictures in the Playback mode to confirm that the
pictures are rotated correctly.
Fig. 6-1-15
1-6-3.
Adjusting Method
1.
CAMERA Adjustment 1
Note:
There is no magnetic substance within around 8 cm of the
camera.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Hall Adj.
3. Auto Orientation Adj.
4. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, the following message and screen are displayed. Set
the camera in accordance with the message.
4) If the [OK] button is clicked, “2. Hall Adj.” will be executed.
5) Upon successful completion of “2. Hall Adj.”, the following
message and screen are displayed. Set the camera in accor-
dance with the message.
(a)
(b)
(c)
6-21
DSC-H7/H9_ADJ
2.
Wide Limit Adjustment
Adjustment to remove variations at the wide end of the inner fo-
cus lens.
Adjustment Block
11
Adjustment Page
61
Adjustment Address
0F18, 0F19
2-1. Adjusting method when the lens is replaced:
Adjusting method:
Order Block
Page
Address
Procedure
1
11
61
0F18
Set the data. (Note)
2
11
61
0F19
Set the data. (Note)
3
Save the data.
4
Perform “Flange Back
Adjustment”.
Note:
The data of block: 11, page: 61, address: 0F18 and 0F19,
that are set in the Orders 1 and 2 as described above, are
shown on the data sheet supplied with the replacement lens
for repair.
Set the upper single byte of the 2-byte data shown on the
sheet to address: 0F19, and the lower byte of the data to the
address: 0F18.
Fig. 6-1-16
Data for Block: 11, 
Page: 61, Address: 0F18
Wide Limit Data (2-byte data)
Data for Block: 11, 
Page: 61, Address: 0F19
XXXX
2-2. Adjusting method when replacement of lens is
not required and the SY-177 board is replaced:
When the data of block: 11, page: 61, address: 0F18 and
0F19 can be read from the defective SY-177 board be-
fore replacement, and both of the data are not “00”:
Adjusting method:
Order Block
Page
Address
Procedur
1
11
61
0F18
Set the previous data
2
11
61
0F19
Set the previous data
3
Save the data.
4
Perform “Flange Back
Adjustment”.
When the data of block: 11, page: 61, address: 0F18 and
0F19 can be read out from the defective SY-177 board
before replacing it, and both of the data are “00”:
1) Replace the lens with the replacement lens and perform “2-1.
Adjusting method when the lens is replaced”.
When the data of block: 11, page: 61, address: 0F18 and
0F19 cannot be read from the defective SY-177 board:
1) Replace the lens with the replacement lens and perform “2-1.
Adjusting method when the lens is replaced”.
6-22
DSC-H7/H9_ADJ
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
Note 2:
When using the flange back adjustment jig, take care of
the following points:
• For the illumination, use a light source such as an in-
candescent lamp or inverter type fluorescent light free
from flickering.
• Do not make an adjustment in the environment where
fluorescent lamp flickering occurs even if the illumi-
nance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent
light at a place free from the influence of room illumi-
nation.
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-18
3.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
Preparation of Flange Back Adj.
(Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note 1:
The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the
minipattern box.
Fig. 6-1-17
Flange back adjustment jig
Below 3 cm
Camera
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Page of 42