Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h50-sm3.pdf
Date

Sony DSC-H50 (serv.man3) Service Manual ▷ View online

6-20
DSC-H50_ADJ
[Adjusting method]
1) If the [Start] button of the CAMERA Adjustment 3 is clicked,
the following message is displayed.
If “Wide Limit Adjustment” is necessary, click the [Cancel]
button to interrupt the Adjustment Program, and perform “2-
3. Wide Limit Adjustment”.
2) If the [OK] button is clicked, the Automatic Adjustment Pro-
gram executes “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation of Flange Back Adj.”.
4) If the [OK] button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK] button.
4.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) Click the [OK] button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
6-21
DSC-H50_ADJ
5.
CAMERA Adjustment 5
Note:
Perform this adjustment only when the Lens Block or CCD
Block Assy was replaced.
[Automatic Adjustment Program execution items and
sequence]
1. Light Falloff Balance Adj.
[Adjusting method]
1) If the [Start] button of the CAMERA Adjustment 5 is clicked,
the following message is displayed.
2) Press the [OK] button, and the “1. Light Falloff Balance Adj.”
will be executed.
3) Upon successful completion of all items of the CAMERA Ad-
justment 5, the following message is displayed. Click the [OK]
button.
6-22
DSC-H50_ADJ
7.
CAMERA Adjustment 6
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain, LV Adj.
5. Mechanical Shutter Adj.
6. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-20 to
Fig. 6-1-22, set the subject and click the [OK] button.
After that, the next message is displayed. Then, change the chart
in accordance with the message.
4) Click the [OK] button, and the items from “3. F No. Compen-
sation” to “6. Release of Data Setting during Camera Adj.”
will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 6, the following message is displayed. Click the
[OK] button.
6.
Picture Frame Setting (Standard Picture Frame)
In the “CAMERA Adjustment 6 and CAMERA Adjustment 7”,
set the picture frame so as to attain the positions shown in the
following figure when shooting the 9 colors chart.
Check on the oscilloscope
Measurement Point: Video terminal of USB, A/V cable for multi-
use terminal (75 
Ω terminated)
1. Horizontal period
Fig. 6-1-20
2. Vertical period
Fig. 6-1-21
Check on the monitor TV or the LCD screen
Fig. 6-1-22
A
A
B
A = B
V
B
C
C
C =
B
3
Transparent window
Effective picture frame
A
A
B
Blue
C14
Magenta
White
Cyan
Red
Yellow
Green
W14
C
C
B
C =
A = B
C14: Filter for AWB 5800K adjustment
A
2
B
3
6-23
DSC-H50_ADJ
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
6) Upon successful completion of “5. Color Reproduction Adj.
& Check”, the following message is displayed. Change the
chart in accordance with the message.
7) Click the [OK] button, and the items from “6. CCD White De-
fect Compensation Check” to “8. Release of Data Setting dur-
ing Camera Adj.” will be executed.
8) Upon successful completion of all items of the CAMERA
Adjustment 7, the following message is displayed. Click the
[OK] button.
8.
CAMERA Adjustment 7
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. AWB 3200K-5800K Standard Data Input
4. AWB 3200K-5800K Check
5. Color Reproduction Adj. & Check
6. CCD White Defect Compensation Check
7. CCD Black Defect Compensation Check
8. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 7.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-20 to
Fig. 6-1-22, set the subject and click the [OK] button.
4) Click the [OK] button, and the “3. AWB 3200K-5800K Stan-
dard Data Input” and “4. AWB 3200K-5800K Check” will be
executed.
5) After that, “5. Color Reproduction Adj. & Check” will be ex-
ecuted. Upon completion of adjustment, the check result is
displayed on the Color Reproduction Check screen.
Page of 39
Display

Click on the first or last page to see other DSC-H50 (serv.man3) service manuals if exist.