DOWNLOAD Sony DSC-H5 (serv.man3) Service Manual ↓ Size: 714.63 KB | Pages: 36 in PDF or view online for FREE

Model
DSC-H5 (serv.man3)
Pages
36
Size
714.63 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h5-sm3.pdf
Date

Sony DSC-H5 (serv.man3) Service Manual ▷ View online

6-29
DSC-H5_ADJ
1-7.
INITIALIZATION  OF  DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note: If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “07”.
4) Click  [All]  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-66 A)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) Click [Save] on the SEUS screen.
10) Select page: 80, address: 34, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
12) Perform “VIDEO OUT Default Data Check” and “Initial Lan-
guage Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 [Set]
(Note)
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click [Connect]
on the SEUS screen to restore the “connected” state. (In
case that the power does not turn on again, press the power
button.)
Fig. 6-1-66
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1: If the 6D or 6E or 6F or 78 or 79 or CE or CF page data
have been initialized, the following adjustment needs to
be performed again.
1) Camera system adjustments
Note 2: If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “07”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-66
B
)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) Click [Save] on the SEUS screen.
10) Select page: 80, address: 34, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
12) When 4F page is initialized, perform “VIDEO OUT Default
Data Check” and “Initial Language Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 [Set]
(Note)
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click [Connect]
on the SEUS screen to restore the “connected” state. (In
case that the power does not turn on again, press the power
button.)
B
A
07
6-30
DSC-H5_ADJ
6-2. SERVICE  MODE
1.
Setting the Test Mode
Page 40
Address A1,  A3
• Forced CAMERA (Auto) mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
• Forced CAMERA (Program Auto) mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 02.
• Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 07.
• Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
• After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
6-31
DSC-H5_ADJ
3.
LED Check
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 40, address: 98, and check that the data is “00”.
3) Select page: 8E, address: FE, and set data: 20.
4) Select page: 80, address: 12, and set data: 01.
5) Check that all LED are lit.
• SELF TIMER/AF ILLUMINATOR
• FLASH CHARGE
• MS ACCESS
6) Select page: 80, address: 12, and set data: 02.
7) Select page: 80, address: 12, and set data: 00.
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
5.
Switch Check (2)
Page 61
Address 90
Using method:
1) Set the mode dial to “P (Program auto)”.
2) Select page: 61, address: 90.
3) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00 When data = 01
Steady shot button
OFF
ON
(CONTROL SWITCH BLOCK (S107))
Function
When data = 00 When data = 01 When data = 02
Shutter button
(XAE LOCK SW)
OFF
ON
ON
(CONTROL SWITCH BLOCK (S103))
Shutter button
(XSHUTTER SW)
OFF
OFF
ON
(CONTROL SWITCH BLOCK (S103))
6-32
DSC-H5_ADJ
6.
Switch Check (3)
Page 20
Address 64
Using method:
1) Select page: 20, address: 64.
2) By discriminating the read data, the state of the switches can
be discriminated.
7.
Switch Check (4)
Page 80
Address 15
Using method:
1) Select page: 80, address: 15.
2) By discriminating the read data, the state of the jog dial can
be discriminated.
8.
Switch Check (5)
Page 40
Address 5F
Using method:
1) Set the mode dial to “P (Program auto)”.
2) Select page: 40, address: 5F.
3) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 01
When data = 11
Lens cap switch
ON
OFF
(AF-105 board S001)
(Lens cap attached)
Function
Data
Jog dial
(When rotated in the left direction)
01
(CONTROL SWITCH BLOCK (S105))
Jog dial
(When rotated in the right direction)
02
(CONTROL SWITCH BLOCK (S105))
Jog dial
(When press the jog dial)
03
(CONTROL SWITCH BLOCK (S105))
Function
When data = 00 When data = 01
PLAY button
OFF
ON
(CONTROL SWITCH BLOCK (S108))
Page of 36
Display