DSC-H300_ADJ
5-4
5-3. CAMERA SECTION ADJUSTMENTS
5-3-1.   Writing Lens data
Introduction:
-  Please handle lens with care.
-  Perform the operation additionally when replacing Main board or Lens.
-  Read and record the lens data on the QR Code Label or Lens data Label attached to the lens. (Fig. 5-3-1)
-  Record of numbers. (7 digit)
010 1118 
Lens data
0 1 0   111 8  
 (Fig. 
5-3-1)
Preparations:
 
Put the folder “Wrirte_Lens Data” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) on any place of the PC.
 
Confirm that includes the following items.
• Write_LensCode_v[][][].exe
• UI43Api.dll
 
The USB Driver is sane as “5-3-12. Set Language Destination”.
Procedure:
1)  Check that the camera is on the adjustment mode.
 
Connect the camera and the PC.
2)   Double click the “Write_LensCode_v[][][].exe” to start up the writing tool. (Fig. 5-3-2)
 
 (Fig. 
5-3-2)
3)  Enter the recorded lens data in the “Data code” text field.
4)  Click the “Write” button.
5)  The message “Write Code To Camera OK !!” will be displayed.
 
 (Fig. 
5-3-3)
5-3-2. Setting Default Gyro Value
Perform the this operation additionally when replacing Main board or Lens.
Preparations: 
 
Put the folder “Set_Default Gyro Value” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) on any place of the PC.
 
Confirm that includes the following items.
• Set_DefaultGyro_v[][][].exe
• UI43Api.dll
 
The USB Driver is sane as “5-3-12. Set Language Destination”. 
Procedure:
1)  Check that the camera is on the adjustment mode.
 
Connect the camera and the PC. 
2)  Double click the “Set_DefaultGyro_v[][][].exe” to start up the writing tool. (Fig. 5-3-4)
3)  Click the “Set Default ” button. 
 
 (Fig. 
5-3-4)
4)  In case of the setting is finished normally, the setting completion indication appears on the screen. (Fig. 5-3-5)
 
The power of the camera turns off automatically.
 
 (Fig. 
5-3-5)
DSC-H300_ADJ
5-5
The adjustment is finished normally.
OB VAL:
R OFFS:
G OFFS:
B OFFS:
0x07a8
0x07a9
0x07aa
Limit:4 3840
Time:2426
FINISH
T
OK
Fig. 5-3-10
The adjustment is complete.
Adjustment order
Screen display
5-3-4. OB Adjustment
The OB (Optically Black) Adjustment order is as follows.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Cover camera lens (All black). (Fig. 5-3-9)
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “OB CLBT (BLACK)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-10)
Press the “      (Playback)” button to return to 
adjustment menu.
Finished normally.
Finished abnormally.
In case of the indication other than that shown in 
Fig. 5-3-10 appears on the screen, confirm the 
adjusting environment and readjust.
Confirm the indication
on the screen.
Camera
Equipment required: Cover camera lens
(All black)
Black cloth
Fig. 5-3-9
5-3-3. Focus Adjustment
The Focus Adjustment order is as follows.
Note: 
When using the Flange back adjustment jig, take care of the following points:
•  For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering.
•  Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only.
•  Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination.
1)  Install the Flange back adjustment jig so that the distance between 
it and the front of lens of camera is 10 mm or less (Tele end).
Note:
Take care not to hit the Flange back adjustment jig when extending the lens.
2)  Make the height of Flange back adjustment jig and the camera equal.
3)  Check that the center of chart meets the center of shot image screen.
Illuminance = 1000 ± 200 lx
Adjustment order
Screen display
The adjustment is finished normally.
******
IN FOCUS
******
0,-1,552
1,0,585
2,-1,660
3,0,743
4,0,810
5,0,882
6,-1,945
7,2,1086
8,0,1221
9,0,1347
10,1,1608
11,0,1683
12,1,1751
13,0,1802
14,0,1840
15,0,1827
16,0,1745
17,1,1565
18,0,1330
19,0,984
20,0,433
Getsum 0x3F
OK
Fig. 5-3-7
The adjustment is complete.
The adjustment is finished abnormally.
******
INF FOCUS
******
Focus Over Range Large ..
Cali Er
NG
Fig. 5-3-8
Malfunction of Focus 
adjustment result
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Flange back adjustment jig. (Fig. 5-3-6)
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-8)
In this case, confirm the adjusting environment
and readjust. 
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “FOCUS (Infinity)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-7)
Press the “      (Playback)” button to return to 
adjustment menu.
Finished normally.
Finished abnormally.
Confirm the indication
on the screen.
Flange back adjustment jig
10 mm or less (Tele end)
Camera
Equipment required: Flange back adjustment jig
Fig. 5-3-6
DSC-H300_ADJ
5-6
Adjustment order
Screen display
Setting Light Src value.
5-3-5. WB/AGC Adjustment
The WB/AGC (White Balance/Analog Gain Control) Adjustment order 
is as follows.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
LimitR:312 579
LimitB:338 628
MEAN G
DayLig
R Gain
G Gain
B Gain
25854
32018
25610
75923
Time:16585
Move OK...
OK
Fig. 5-3-13
The adjustment is complete.
The adjustment is finished abnormally.
Limit:234 276
49 8, 191
ZPos :
WLuma:
LS:-1 3:
OC:
63
OC :
Entry :
Gain :
AGC :
0x002e
0x0101
OK
NG
Cali Er
T
Fig. 5-3-14
Malfunction of WB/AGC  
adjustment result
5-3-6. MeShut26 Adjustment
The MeShut26 (Mechanical Shutter 26) Adjustment order is as follows.
Note:
Perform the MeShut26 Adjustment after those performed in 5-3-4 to 5-3-5.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Iris No:
1
Time:605
OK
FINISH...
Fig. 5-3-16
The adjustment is complete.
Adjustment order
Screen display
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Confirm the indication
on the screen.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-14)
In this case, confirm the adjusting environment
and readjust. 
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “WB/AGC (LV10)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-13)
Press the “      (Playback)” button to return to 
adjustment menu.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item to “WB/AGC (LV10)”, 
and press the “       (Playback)” button. Press the Control button “ v ” “ V ” to change selected item 
to “Light Src”, and press the Control button “ b ” “ B ” to set the value as “00002”, and press the 
Control button “ z ”. (Fig. 5-3-12)
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-11)
Finished normally.
Finished abnormally.
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the indication other than that shown in
Fig. 5-3-16 appears on the screen, confirm the
adjusting environment and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MeShut26 (LV13)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-16)
Press the “      (Playback)” button to return to 
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-15)
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 5-3-11
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 5-3-15
Disable
00001
LightSrc
00002
P1RRatio
01078
P1BRatio
01031
P2RRatio
01458
P2BRatio
00619
Fig. 5-3-12
DSC-H300_ADJ
5-7
5-3-7. MeShut80 Adjustment
The MeShut80 (Mechanical Shutter 80) Adjustment order is as follows.
Note:
Perform the MeShut80 Adjustment after those performed in 5-3-4 to 5-3-6.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Limit:550 678
CAPNUM :
DRAFT_G:
Iris No:
STILL_G:
MainDly:
SubDly :
79
76
622
442
2
2
Time:14958
OK
FINISH..
.
Fig. 5-3-18
The adjustment is complete.
The adjustment is finished abnormally.
...Iris or LV NG
CAPNUM :
DRAFT_G:
Iris No:
STILL_G:
MainDly:
SubDly :
2
2
Time:686
Calib Er 
..
NG
Fig. 5-3-19
Malfunction of MeShut80 
adjustment result
Adjustment order
Screen display
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-19)
In this case, confirm the adjusting environment
and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MeShut80 (LV14)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 5-3-18)
Press the “      (Playback)” button to return to 
adjustment menu.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-17)
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 5-3-17
Adjustment order
Screen display
5-3-8. Dark DP Adjustment
The Dark DP (Dead Pixel) Adjustment order is as follows.
Note:
Perform the Dark DP Adjustment after those performed in 5-3-4 to 5-3-7.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Cap Raw  ...
Threshold :
Find DP NUM
Time (Sec)
DARK DPC
512
4
13
1
FINISH  ....
OK
Fig. 5-3-21
The adjustment is complete.
The adjustment is finished abnormally.
Cap Raw  ...
Threshold :
Find DP NUM
Time (Sec)
DARK DPC
602
99
41
1
FINISH  ....
NG
Fig. 5-3-22
Malfunction of Dark DP 
adjustment result
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the adjustment is finished abnormally, 
the following indication appears on the screen.
(Fig. 5-3-22)
In this case, confirm the adjusting environment
and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “Dark DPC (LV10)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally,
the adjustment completion indication appears 
on the screen. (Fig. 5-3-21)
Press the “      (Playback)” button to return to 
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-20)
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 5-3-20
Page of 11
Display

Sony DSC-H300 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony DSC-H300 (serv.man2) Service Manual ↓ Size: 298.85 KB | Pages: 11 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DSC-H300 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony DSC-H300 (serv.man2) Digital Camera. Information contained in Sony DSC-H300 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.