DOWNLOAD Sony DSC-H10 (serv.man3) Service Manual ↓ Size: 822.47 KB | Pages: 40 in PDF or view online for FREE

Model
DSC-H10 (serv.man3)
Pages
40
Size
822.47 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h10-sm3.pdf
Date

Sony DSC-H10 (serv.man3) Service Manual ▷ View online

6-36
DSC-H10_ADJ
(3) AGING_MREC
In the AGING_MREC mode, motion pictures are continuously
recorded for the time (sec.) set to the “Rec Time” at the interval
(sec.) set to the “Rec Interval”.
At the start of AGING_MREC, the counter in the camera is ini-
tialized. This counter counts the number of recording times dur-
ing the execution of AGING_MREC, and it holds the counts
even during the power off.
AGING_MREC screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Rec Time setting and display
The setting of recording time (sec.) is displayed. The setting
can be changed by entering a numeric value in this field.
3
Rec Interval setting and display
The setting of recording interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
4
[START] button
The AGING_MREC starts. In the AGING_MREC mode, the
aging starts immediately when the [START] button is clicked.
At the battery end, the AGING_MREC stops. To interrupt the
AGING_MREC, use the [STOP]  button, though the
AGING_MREC stops also by the power off or RESET button.
5
[STOP] button
The AGING_MREC stops.
6
[GET] button
After the AGING_MREC was executed, the number of record-
ing times is got from the counter in the camera. The result is
displayed in the “Count” display field.
7
Count display
The number of recording times got by the [GET] button is dis-
played.
(4) AGING_PB
In the AGING_PB mode, pictures are continuously played back at
the interval (sec.) set to the “Play Back Interval”.
At the start of AGING_PB, the counter in the camera is initial-
ized. This counter counts the number of play back times during
the execution of AGING_PB, and it holds the counts even during
the power off.
AGING_PB screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Play Back Interval setting and display
The setting of play back interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
3
[START] button
The AGING_PB starts. In the AGING_PB mode, the aging
starts immediately when the [START] button is clicked.
At the battery end, the AGING_PB stops. To interrupt the
AGING_PB, use the [STOP] button, though the AGING_PB
stops also by the power off or RESET button.
4
[STOP] button
The AGING_PB stops.
5
[GET] button
After the AGING_PB was executed, the number of play back
times is got from the counter in the camera. The result is dis-
played in the “Count” display field.
6
Count display
The number of play back times got by the [GET]  button is
displayed.
6
4
5
1
7
2 3
5
3
4
1
6
2
6-37E
DSC-H10_ADJ
2-3.
DATA  BACKUP
With the “DATA BACKUP”, the adjustment data in the camera
can be backed up in the PC as a file.
The adjustment data that can be backed up are as follows.
System Control Section:
1) Video System Adjustments
2) LCD System Adjustments
Camera Control Section:
1) Camera System Adjustments
1.
Function of Each Button on Data Backup Screen
Click the [DATA BACKUP] button on the Main Menu screen, and
the “DATA BACKUP” screen in Fig. 6-2-3 will appear.
Fig. 6-2-3
1
[To Menu] button
Return to the main menu.
2
[Data Read and Save] button
Read the adjustment data from the camera and save them in
PC as a file.
Default file name is as follows:
3
[Data Load and Write] button
Load the adjustment data from the file saved in PC and write
them to the camera.
DSC-H10_ADJBAK_xxxxxxxx_yyyymmdd.dat
Date
USB serial number
Data name
1
2
3
Revision History (1/2)
Reverse
DSC-H10_ADJ
Ver.
1.0
1.1
1.2
1.3
Date
2008.02
2008.05
2008.06
2008.06
History
Official Release
Revised-1
(A1 DI08-085)
Revised-2
(A2 DI08-134)
Revised-3
(A3 DI08-177)
Contents
Replacement of the previously issued SER-
VICE MANUAL 9-852-268-51 with this
Manual.
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program
has been changed from Ver_1.0r01 to
Ver_1.1r02.
• Addition of Thai Model
S.M. revised:
Page 6-8
Page 6-10
Replacement of the previously issued SER-
VICE MANUAL 9-852-268-52 with this
Manual.
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program
has been changed from Ver_1.1r02 to
Ver_1.2r03.
• Addition of the “Setting Distance between
Pattern Box and Camera”
• Addition of the “Precautions When Using
Pattern Box”
• Correction of the “Setting of Adjustment
Mode”
S.M. revised:
Page 6-3
Page 6-5
,
Page 6-6
Page 6-8
,
Page 6-9
Replacement of the previously issued SER-
VICE MANUAL 9-852-268-53 with this
Manual.
• Correction of the “Setting of Adjustment
Mode”
S.M. revised:
Page 6-9
– Continued on next page –
S.M. Rev.
issued
Yes
Yes
Yes
985226855.pdf
Revision History (2/2)
Reverse
DSC-H10_ADJ
Ver.
1.4
Date
2009.04
History
Revised-4
(A4 09-010)
Contents
Replacement of the previously issued SER-
VICE MANUAL 9-852-268-54 with this
Manual.
• Change of  Automatic Adjustment Program
Version of Automatic Adjustment Program
has been changed from Ver_1.2r03 to
Ver_1.4r04.
• Automatic Adjustment Program
compatibility on Windows Vista
S.M. revised:
Page 6-2
,
 Page 6-3
,
Page 6-4
Page 6-8
S.M. Rev.
issued
Yes
985226855.pdf
Page of 40
Display