Sony DSC-G1 (serv.man5) Service Manual ▷ View online
SERVICE MANUAL
Auto-ADJ
Ver. 1.2 2007.05
Sony EMCS Co.
9-852-175-82
2007E0500-1
© 2007.5
Published by Kohda TEC
SUPPLEMENT-2
File this supplement with the service manual.
(DI07-015)
DSC-G1
DSC-G1_ADJ
(ENGLISH: Pages 1 and 2)
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program has
been changed from Ver_1.0r01 into Ver_1.2r02.
been changed from Ver_1.0r01 into Ver_1.2r02.
: Points changed portion.
6-1. CAMERA SECTION ADJUSTMENTS
1-2.
ADJUSTMENT PROGRAM
2.
Start of Automatic Adjustment Program
(Service manual page 6-7)
Double-click the application file (DSC-G1 Auto-Adj
Ver_1.2r02.exe), and the Automatic Adjustment Program will start.
Double-click the application file (DSC-G1 Auto-Adj
Ver_1.2r02.exe), and the Automatic Adjustment Program will start.
3.
Function of Each Button on Main Menu Screen
(Service manual page 6-7)
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
Fig. 6-1-9
qa
This part indicates the version of Automatic Adjustment Pro-
gram.
gram.
3
5
4
7
6
2
1
9
0
8
qa
• Change of Automatic Adjustment Program
• Addition of [Read], [Save], and [Load] buttons to Angular
• Addition of [Read], [Save], and [Load] buttons to Angular
Velocity Sensor Sensitivity Adjustment
— 2 —
DSC-G1_ADJ
• Addition of [Read], [Save], and [Load] buttons
to Angular Velocity Sensor Sensitivity Adjust-
ment
ment
&
: Points added portion.
1-6.
CAMERA SYSTEM ADJUSTMENTS
1-6-3.
Adjusting Method
9.
CAMERA Adjustment 7
(Service manual page 6-21)
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
9-1. Precaution before adjustment
Before adjustment, read the following data and record them.
When the SY-153 board is replaced, read out the data before the
replacement, and record them.
Before adjustment, read the following data and record them.
When the SY-153 board is replaced, read out the data before the
replacement, and record them.
Reading out method:
1) Read out the data in Block:11, Page:61, Address:0E10, and
1) Read out the data in Block:11, Page:61, Address:0E10, and
name this as Dp.
2) Read out the data in Block:11, Page:61, Address:0E11, and
name this as Dy.
Note: The previous data (Dp, Dy) can be read from the SY-
Note: The previous data (Dp, Dy) can be read from the SY-
153 board and it can be saved in the PC as a file by
using the Automatic Adjustment Program. (Refer to “9-
4. Angular Velocity Sensor Sensitivity Adjustment”)
using the Automatic Adjustment Program. (Refer to “9-
4. Angular Velocity Sensor Sensitivity Adjustment”)
(
: Points changed portion.
9-4.
Angular Velocity Sensor Sensitivity Adjustment
(Service manual page 6-22)
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
[Read] button: Reads and displays the previous data (Dp, Dy)
from the SY-153 board.
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
file.
[Load] button: Loads and displays the previous data (Dp, Dy)
from the file saved in the PC.
Note: The previous data (Dp, Dy) is saved with the file name
“DSC_G1_DpDyData.dat” in the same folder as the Au-
tomatic Adjustment Program.
tomatic Adjustment Program.
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
at lower left of screen.
3) Input the sensitivity of respective sensors (S
601
, S
602
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
ates normally.
— 3 —
DSC-G1_ADJ
(JAPANESE: Pages 3 and 4)
・ 自動調整プログラムの変更
自動調整プログラムのバージョンがVer_1.0r01か
らVer_1.2r02へ変更しました。
らVer_1.2r02へ変更しました。
:変更箇所
6-1. カメラ部調整
1-2.
自動調整プログラム
2. 自動調整プログラムを起動する
(Supplement-1 6-7ページ)
ア プ リ ケ ー シ ョ ン フ ァ イ ル( D S C - G 1 A u t o - A d j
Ver_1.2r02.exe)
をダブルクリックすると,自動調整プログラ
ムが起動します。
3. メインメニュー画面と各ボタンの働き
(Supplement-1 6-7ページ)
自動調整プログラムを起動すると,図6 - 1 - 9 のメインメ
ニュー画面が表示されます。この画面で各調整セクションを
選びます。
図6-1-9
qa
自動調整プログラムのバージョンがこの部分に表示されます。
・ 角速度センサ感度調整に[Read],[Save],[Load]
ボタンを追加
&
:追加箇所
1-6.
カメラ系調整
1-6-3. 調整方法
9. カメラ調整 7
9. カメラ調整 7
(Supplement-1 6-22ページ)
この調整は,角速度センサまたはレンズブロックの交換時に
この調整は,角速度センサまたはレンズブロックの交換時に
のみ行ってください。
マイコン,回路等が壊れた場合は調整は行わず,動作確認の
みを行ってください。
9-1. 調整前の注意
調整前に次のデータを読み出し,記録しておいてください。
調整前に次のデータを読み出し,記録しておいてください。
SY-153基板の交換時には,交換前にデータを読み出して記
録しておいてください。
[読み出し方法]
1) ブロック : 11,ページ : 61,アドレス : 0E10を読み
1) ブロック : 11,ページ : 61,アドレス : 0E10を読み
出し,Dpとする。
2) ブロック : 11,ページ : 61,アドレス : 0E11を読み
出し,Dyとする。
注:自動調整プログラムを使用してSY-153基板から元の
データ
(D
P
, D
Y
)
を読み出してPCにファイルとして保存
することができます。
(「9-4. 角速度センサ感度調整」
を参照)
3
5
4
7
6
2
1
9
0
8
qa
(
— 4 —
DSC-G1_ADJ
9-4. 角速度センサ感度調整
(Supplement-1 6-23ページ)
:変更箇所
[調整方法]
1)カメラ調整7の [Start] ボタンをクリックすると,次のよ
1)カメラ調整7の [Start] ボタンをクリックすると,次のよ
うな画面が表示されます。
この画面上のボタンは以下の機能を提供しています。
[Read] ボタン : SY-153基板から元のデータ(Dp, Dy)を
読み出して表示します。
[Save] ボタン : 元のデータ(Dp, Dy)をPCにファイルと
して保存します。
[Load] ボタン : PCに保存されたファイルから元のデー
タ
(Dp, Dy)
をロードして表示します。
注: 元のデータ(Dp, Dy)は,「DSC_G1_DpDyData.dat」
というファイル名で自動調整プログラムと同じホル
ダー内に保存されます。
2)元のデータ
(Dp,Dy)
を画面に入力してください。
元のデータが読み出せなかった場合は,画面の左下の
チェックボックスにチェックを入れてください。
3)「準備」
で読み取ったそれぞれのセンサ
(S
601
,S
602
)
の感度
を画面に入力してください。
片方のセンサのみを交換したときは,交換しなかったセ
ンサの左下のチェックボックスにチェックを入れてくだ
さい。
4)「準備」で読み取ったレンズのPITCH/YAWデータ(L
1
,
L
2
)
を画面に入力してください。
レンズ交換をしていない場合は,左下のチェックボック
スにチェックを入れてください。
5)[OK] ボタンをクリックすると,調整データは入力した値
から計算され,その結果がカメラのメモリに書き込まれ
ます。
6)データの書き込みが正常に終了すると,次の画面が表示
されます。手振れ補正機能が正常に動作するか確認して
ください。
Display