DOWNLOAD Sony DSC-F88 (serv.man4) Service Manual ↓ Size: 713.16 KB | Pages: 28 in PDF or view online for FREE

Model
DSC-F88 (serv.man4)
Pages
28
Size
713.16 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f88-sm4.pdf
Date

Sony DSC-F88 (serv.man4) Service Manual ▷ View online

6-23
DSC-F88
1-7.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0D”.
4) Click 
[All]
  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-55 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Select page: 8E, address: 00 and set data: 20.
9) Click 
[Save]
 on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29 
[Set]
2
20
01
29 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click 
[Connect]
  on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
Fig. 6-1-55
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6E or 6F page data have been initialized, the fol-
lowing adjustment needs to be performed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0D”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-55
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
9) Click 
[Save]
 on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29 
[Set]
2
20
01
29 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click 
[Connect]
  on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
B
A
0D
6-24
DSC-F88
6-2. SERVICE MODE
1.
Setting the Test Mode
Page 2F
Address 23
Data
Function
80
Normal
00
Forced CAMERA mode
10
Forced PLAY mode
11
Forced MOVIE mode
• Before setting the data, select page: 00, address: 01, and set
data: 01.
• For page: 2F, the data set is recorded in non-volatile memory by
saving data. In this case, the Test mode is not released even if
the camera is turned off, thus requiring extreme care.
• After completing adjustments/repairs, release the data setting.
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 23, and set data: 80.
3) Save the data.
4) Wait for more than 3 sec.
5) Select page: 80, address: 30, and check that the data is “00”.
6) Select page: 00, address: 01, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
6-25
DSC-F88
3.
LED Check
Page 20
Address 04
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 20, address: 04, and set data: 02.
3) Select page: 8E, address: FE, and set data: 20.
4) Select page: 80, address: 12, and set data: 01.
5) Check that all LED are lit.
• SELF TIMER/AF ILLUMINATOR
• SELF TIMER/RECORRDING
• AE/AF LOCK
• FLASH CHARGE
• MS ACCESS
6) Select page: 80, address: 12, and set data: 00.
7) Select page: 20, address: 04, and set data: 00.
8) Select page: 8E, address: FE, and set data: 00.
9) Select page: 00, address: 01, and set data: 00.
10) Click 
[Disconnect]
 on the SEUS screen.
11) Disconnect the USB cable.
12) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
5.
Switch Check (2)
Page 20
Address 20
Using method:
1) Select page: 20, address: 20.
2) By discriminating the bit value of read data, the state of the
switches can be discriminated.
Function
When data = 00 When data = 01 When data = 02
Shutter button (XAE LOCK SW)
(CONTROL SWITCH BLOCK
OFF
ON
ON
(MODE) S003)
Shutter button (XSHTR ON SW)
(CONTROL SWITCH BLOCK
OFF
OFF
ON
(MODE) S003)
Bit
Function
When bit value = 1
When bit value = 0
2
LENS OPEN
(KK-031 board S001)
OPEN
CLOSE
6-26
DSC-F88
6. Switch Check (3)
Page 20
Addresses 90 to 92
Using method:
1) Select page: 20, addresses: 90 to 92.
2) By discriminating the read data, the pressed key can be dis-
criminated.
7. Mode Dial Check
Page 20
Addresses 95, 96
Using method:
1) Select page: 20, addresses: 95 and 96.
2) By discriminating the read data, the state of the mode dial can be discriminated.
Display Code
  C:32:ss
  C:13:ss
Countermeasure
Turn the power off and on again.
Format the “Memory stick”.
Insert a new “Memory Stick”.
Cause
Trouble with hardware.
Unformatted memory stick is inserted.
Memory stick is broken.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
  E:61:ss
  E:91:ss
Checking of lens drive circuit.
When failed in the focus and zoom
initialization.
Abnormality when flash is being
charged.
Checking of flash unit or replacement
of flash unit.
8. Self Diagnosis Code
6-26E
Address
Data
00 to 0C
0D to 27
28 to 48
49 to 73
74 to A5
A6 to DC
DD to FF
CONTROL
MENU
DISPLAY/
ZOOM W
LENS
LENS
90
RIGHT
(Control switch
LCD ON/OFF
(Control switch
REVERSE
NORMAL
(KEY AD0)
(Control switch
block (SW))
(Control switch
block (SW))
(KK-031 board) (KK-031 board)
(IC401 
J6
 )
block (SW))
(S002)
block (SW))
(S009)
(S002)
(S002)
(S007)
(S001)
CONTROL
CONTROL
CONTROL
CONTROL
91
LEFT
DOWN
SET
UP
(KEY AD1)
(Control switch (Control switch (Control switch (Control switch
No key input
(IC401 
H6
 )
block (SW))
block (SW))
block (SW))
block (SW))
(S003)
(S006)
(S004)
(S005)
IMAGE SIZE/
ZOOM T
92
DELETE
(Control switch
(KEY AD2)
(Control switch
block (SW))
No key input
(IC401 
G6
 )
block (SW))
(S010)
(S008)
Address
Data
00 to 0C
0D to 27
28 to 48
49 to 73
74 to DC
DD to FF
95
AUTO
P (Program Auto)
M (manual)
SCN
(MODE
(Control switch
(Control switch
(Control switch
(Control switch
Others
DIAL0)
block (MODE)
block (MODE)
block (MODE)
block (MODE)
(IC401 
J8
 )
S002)
S002)
 S002)
S002)
96
PLAY
MOVIE
SET UP
(MODE
(Control switch
(Control switch
(Control switch
Others
DIAL1)
block (MODE)
block (MODE)
block (MODE)
(IC401 
J9
 )
S002)
S002)
S002)
Page of 28