10
XVM-R70
3-5. LCD BLOCK ASSY
3-6. CASE (LCD REAR)
1
two screws
     (+
PS 3 x 10
)
2
two screws
     (+
PS 3 x 10
)
3
LCD block assy
4
two screws
     (+
P 2 x 8
)
3
window (IR)
1
four claws
5
claw
6
claw
7
claw
three claws
two claws
8
claw
9
claw
qs
case (LCD rear)
0
claw
qa
2
four claws
11
XVM-R70
3-7. CHASSIS (LCD)
1
two tscrews
     (+
P 2 x 8
)
qf
chassis (LCD)
2
screw
     (+
P 2 x 8
)
3
screw
     (+
P 2 x 8
)
4
two screws
     (+
P 2 x 5
)
0
CN401
qa
CN403
qs
CN902
qd
CN404
LCD board
5
two screws
     (+
P 2 x 5
)
8
two screws
     (+
P 2 x 5
)
9
6
screw
     (+
P 2 x 5
)
7
screw
     (+
P 2 x 5
)
12
XVM-R70
3-8. LCD BOARD
3-9. LCD1
0
two screws
     (+
P 2 x 8
)
9
two tscrews
     (+
P 2 x 8
)
qa
LCD board
3
screw
     (+
B 2 x 6
)
6
screw (+
B 2 x 6
)
4
lug
5
retainer (LCD)
7
retainer (LCD)
8
tirminal (LCD)
1
CN800
2
CN850
1
two screws
     (+
B 2 x 6
)
3
screw
     (+
B 2 x 6
)
5
screw
     (+
B 2 x 6
)
2
two retainers (LCD, B)
4
retainer (LCD)
8
LCD1
6
retainer (LCD)
7
insulating sheet (LCD)
13
XVM-R70
3. For each item selected, adjust so that the adjustment value is
within the specified value range using the  
R
  and 
 
r
  keys on the
remote controller.
4. After adjustment, press the  MENU  key on the remote controller
to determine the adjustment value.  Press the  MENU  key once
more to change to the next item.
5. After all necessary adjustments are completed, select EXIT
using the  MENU  key on the remote controller and press the
 INPUT  key to display the MENU screen.  Then, select No.7,
SOFT REST using the  MENU  key and determine the selection
using the  INPUT  key to terminate the TEST mode.
SECTION 4
TEST MODE
Setting Method:
1. Place the  POWER SELECT  switch on the set into the B posi-
tion.
2. Turn power on.  While holding the  RESET  key down, depress
the  
R
  key.  Then release the  RESET  key and the  
R
  key in this
order.
3. TEST MODE MENU is indicated.
Terminating Method:
Select the MENU No. 7, SOFT REST using the  MENU  key on the
remote controller and determine the selection using the  INPUT
key.
The FOR FACTORY Mode:
The FOR FACTORY mode can be used to perform 13 different
adjustment items with the remote controller.
1. Select the MENU No. 2, FOR FACTORY using the  MENU  key
on the remote controller and determine the selection using the
 INPUT  key.
2. The FOR FACTORY mode is now entered.  The following items
are selected in turn by pressing the  INPUT  key repeatedly.
V Com
Y Gain
Black Limt 
White Limt 
R SUB BRT 
B SUB BRT
R SUB CONT 
B SUB CONT 
Gamma1
Gamma2 
VCO Free
PLL/V Pos
H Pos
Ver 1.1
Page of 64
Display

Click on the first or last page to see other XVM-R70 service manuals if exist.