9
INSTALLATION  OF  FLAT  CABLE (L)  26P
Note:
 Follow the assembly procedure in the numerical order given.
SECTION  3
ASSEMBLY
7
two screws
(M2 
×
 3)
6
FFC cover (2)
5
5
3
B board
4
four screws
(B2.6 
×
 4)
2
two flat cables (L) 26P
(CN705, 706)
4
screw
(B2.6 
×
 4)
B board
two flat cables (L) 26P
chassis (lower)
ass’y
Note: No slack is allowed.
filament tape 16 
× 
50
8
Using a filament tape 16 
× 
50,
stick two flat cables (L) 26P 
to the chassis bottom without a slack 
as shown in the figfure.
base ass’y
1
Pull the base ass’y 
in the direction of arrow 
A.
A
0
Pull the flat cable (L) 26P in the direction of arrow B,
and stick it to the sheet (FFC) with an adhesive tape.
DC motor (small type) (slide) (M21)
B
adhesive tape
sheet (FFC)
qs
screw (M2 
×
 3)
qa
FFC cover (1)
0
Pull the flat cable (L) 26P 
in the direction of arrow 
C
and stick it to the sheet (FFC)
with an adhesive tape.
C
adhesive tape
sheet (FFC)
9
flat cable (L) 26P
(CN101)
9
Let the flat cable (L) 26P through 
under DC motor (small type) (slide) (M21)
as shown in the figure, and connect to 
the connector (CN102). 
10
SECTION  4
TEST  MODE
Test mode setting
1. Press the 
[OPEN/CLOSE]
 button to place the set in open state.
2. Press the 
[V ADJ]
 button and 
[TV/VIDEO]
 button simulta-
neously.
3. A beep sounds and the test mode is activated.
Note: 
The test mode is active for several seconds only, and it returns to
normal state if no operation is performed during this time. When
the test mode is activated, perform the following operation imme-
diately.
Monitor position initializing
Return the position and angle at the time of monitor open state to
the initial position set in the factory.
1. Immediately after the Test mode is activated, press the
[SEARCH --]
 button and 
[TV/VIDEO]
 button. (A beep will
sound)
2. Press the RESET button, and the monitor is stored and the
monitor position is initialized. (Normal state will get back)
11
SECTION  5
ELECTRICAL  ADJUSTMENTS
MAIN  SECTION
5.35 V Adjustment
Connection:
Adjustment Procedure:
1. Connect a digital voltmeter to the TP1 (5.35 V) on the A board.
2. Adjust RV501 on the A board so that digital voltmeter reading
is 5.35 V.
Inverter Standard Frequency Adjustment
Connection:
Adjustment Procedure:
1. Connect a frequency counter to the CL299 on the A board.
2. Adjust RV502 on the A board so that frequency counter read-
ing is 115 ± 2 kHz.
Adjustment Location:
digital voltmeter
A board
TP1 (5.35 V)
+
RV501
5.35 V 
Adjustment
RV502
INVERTER
STANDARD
FREQUENCY
Adjustment
TP1 (5.35 V)
CN401
– A BOARD (Side A) –
A board
CL299
+
frequency counter
CL299
– A BOARD (Side B) –
12
MONITOR  SECTION
Equipment Used
The measuring equipment below are used for these electrical
adjustments:
• Oscilloscope
• NTSC pattern generator
• PAL pattern generator
• Regulated DC power supply
• Digital voltmeter
Connection of Equipment
Unless otherwise specified, the measuring equipment should be
connected as shown below:
Setup at Adjustment
1. Press the 
[SEL]
 button of the wireless remote commander, set
the image quality of the set to “VISUAL STD”.
2. The adjustment signal is a 5-step gray scale signal from a NTSC
pattern generator.
Input the gray scale signal into the tuner unit and connect an
oscilloscope to TP415 on the G board. Check that the width
between the black and white levels of the gray scale signal is
0.74 Vp-w.
Bright Adjustment
Adjustment Procedure:
1. Display the gray scale on the monitor screen.
2. Connect a digital voltmeter to TP (BRIGHT) on the G board.
3. Adjust RV405 so that the reading on the digital voltmeter is
2 V.
Adjustment Location: See page 13.
ACC cord
TV tuner unit
XT-991V
NTSC pattern 
generator
MONITOR 
OUT jack
INPUT (1)
(VIDEO)
jack
TV monitor
XVM-75V
regulated DC 
power supply
(DC 14.4 V)
ACC cord
Connection 
cord
parking brake terminal
(Connected to ground)
VIDEO OUT
(75 
)
+
 white
 black
 0.74 Vp-p
V COM Amplitude/Bias Adjustment
Adjustment Procedure:
1. Display the gray scale on the monitor screen.
2. Connect an oscilloscope to TP (COM) on the G board.
3. V COM Amplitude Adjustment
Adjust RV401 so that the amplitude of the output waveform is
6.0 V.
4. V COM Bias Adjustment
Adjust RV409 so that the level A of the output waveform is at
4.3 V DC.
Adjustment Location: See page 13.
RGB Amplitude Adjustment
Adjustment Procedure:
1. Display the gray scale on the monitor screen.
2. Connect a oscilloscope to TP (G) on the G board.
3. Adjust RV406 so that the white and the next step of pedestal
are on the same level.
Adjustment Location: See page 13.
γ
 0 Adjustment
Adjustment Procedure:
1. Display the gray scale on the monitor screen.
2. Connect an oscilloscope to TP (G) on the G board.
3. Adjust RV407 so that the third step from the bottom becomes
1.2 V.
Adjustment Location: See page 13.
6.0 Vp-p
0 V
A
pedestal
pedestal
white
white
1.2 V
GND
Page of 46