DOWNLOAD Sony XTL-6100MK2 Service Manual ↓ Size: 5.39 MB | Pages: 40 in PDF or view online for FREE

Model
XTL-6100MK2
Pages
40
Size
5.39 MB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
xtl-6100mk2.pdf
Date

Sony XTL-6100MK2 Service Manual ▷ View online

7
2
 screws (M2x5), 
     tapping, P3
1
 screw (M2x5), 
     tapping, P3
3
 screws (M2x5), tapping, P3
5
 MAIN board
4
 CN3
switch
ground terminal
1
 screws (2.6x6)
4
 stand bracket
2
 screws (2.6x6)
3
 screws (2.6x6)
8
 CN601
9
 CN8
0
 rear panel assy (6100)
5
 screws (M2x5), 
     tapping, P3
6
 screws (M2x5), tapping, P3
7
 screws, precision (P2x3), type3
SECTION 2
DISASSEMBLY
Note : Follow the disassembly procedure in the numerical order given.
2-1. REAR PANEL ASSY
2-2. MAIN BOARD
8
1
2
3
4
5
6
7
8
white level (1st step)
black level (8th step)
0 V
INPUT 1
VIDEO
color bar
generator
XT-993V
XVM-6100MK2
VIDEO output
(75 
)
MONITOR OUT
SECTION 3
ELECTRICAL ADJUSTMENTS
 MONITOR SECTION
Equipment
Use the following test equipment for alignment.
• Oscilloscope dual trace, 10 MHz band or above with delay mode
(use a 10 to 1 probe unless otherwise instructed.)
• PAL color bar generator
• DC power supply
• Digital voltmeter
• XT-993V (Hideaway unit)
• Frequency counter
Equipment Connections
Make the test equipment connections as shown below (unless
instructed otherwise) and perform the alignment.
Voltage Adjustment
Setting :
DIMMER selector (S701) : HIGH
BRIGHT dial (RV702)
: Max. (light)
VOL dial (RV301)
: Max.
Procedure :
1. Input the color bar (chroma off) signal from PAL color bar gen-
erator and display on the monitor screen.
2. Connect the digital voltmeter to CL66 on the monitor main
board.
3. Adjust RV401 (+5V) so that the digital voltmeter reads 5 ± 0.1 V
DC.
4. Connect the digital voltmeter to CL86 on the monitor main
board.
5. Adjust RV601 (+9V) so that the digital voltmeter reads 8.5 ± 0.1 V
DC.
Connection points : Monitor main board
Alignment points : Monitor main board
RGB Adjustment
Procedure :
1. Input the color bar (chroma off) signal from PAL color bar gen-
erator and display on the monitor screen.
2. Connect the digital voltmeter to CL151 on the monitor main
board.
3. Adjust RV213 (OFFSET) so that the digital voltmeter reads 2.3
± 0.1 V DC.
4. Connect the oscilloscope to CL42 on the monitor main board.
5. Adjust RV212 (COM CUT) so that the lower black level is 6.2
± 0.05 V DC.
6. Adjust RV208 (COM DRIVE) so that the upper 100% white
level is 9.2 ± 0.05 V DC.
7. Repeat steps 5 & 6 until the items in the standards are satisfied.
8. Connect the oscilloscope to CL41 of the monitor main board.
9. Adjust RV207 (R DRIVE) so that the lower black level is 6.2 ±
0.05 V DC.
10. Adjust RV202 (R CUT) so that the upper 100% white level is
9.2 ± 0.05 V DC.
11. Repeat steps 9 & 10 until the items in the standards are satisfied.
12. Connect the oscilloscope to CL43 of the monitor main board.
13. Adjust RV209 (B DRIVE) so that the upper 100% white level
is 6.1 ± 0.05 V DC.
14. Adjust RV204 (B CUT) so that the upper 100% white level is
9.1 ± 0.05 V DC.
15. Repeat steps 13 & 14 until the items in the standards are satisfied.
Connection points : Monitor main board
Alignment points : Monitor main board
9
– MONITOR MAIN BOARD (SIDE B) 
CL44
CL43
CL41
CL66
CL42
CL151
RV207
R DRIVE
ADJ
RV208 
COM DRIVE
ADJ
RV213
OFFSET
ADJ
RV212
COM CUT
ADJ
RV202
R CUT
ADJ
RV209
B DRIVE ADJ
RV204
B CUT ADJ
RV210
V COM AMP ADJ
RV211
V COM BIAS ADJ
RV401
+5V ADJ
RV601
+9V ADJ
– MONITOR MAIN BOARD (SIDE A) 
A
B
0 V
V COM Adjustment
Procedure :
1. Connect the oscilloscope to CL44 on the monitor main board.
2. Adjust RV210 (V COM AMP) & RV211 (V COM BIAS) so
that the output waveform is within the standards.
3. Repeat step 2 until the standards are satisfied.
Standard values :
A : Adjust RV210 so the value is 4.9 ± 0.1 Vp-p.
B : Adjust RV211 so the value is 5.1 ± 0.1 V.
Connection points : Monitor main board
Alignment points : Monitor main board
10
2.5 Vp-p
0 V
38.9 MHz
T1= 40.9 MHz
T2= 31.9 MHz
0.7 V
0.3 V
0.3 V
red
white (approx. 100%)
horizontal sync. signal
burst signal (flat)
TV SG
set
POWER (CN4)
RF out
ANT IN
DC
power supply
TRAP Adjustment
Procedure:
1. With the Power off, input the output of TG to TP30 (with DC
cut by a capacitor (0.01 µF)).
2. Connect a spectrum analyzer to TP31 (with DC cut by a
capacitor (0.01 µF)).
3. Adjust T1 so that the waveform peak is 40.9 MHz ± 50 Hz.
4. Adjust T2 so that the waveform peak is 31.9 MHz ± 50 Hz.
5. After this adjustment, open TP30 and TP31. (Disconnect the
spectrum analyzer.)
VCO Adjustment
Procedure:
1. No connection to ANT IN. (no signal state)
2. Connect a resistor (10 k
) between TP33 and +9 V (TP35).
3. Connect a spectrum analyzer to TP34 (with DC cut by a
capacitor (0.01 µF)).
4. Adjust T3 so that the waveform peak is 38.9 MHz ± 1 kHz.
5. After this adjustment, open TP34. (Disconnect the spectrum
analyzer.)
AGC Adjustment
Procedure:
1. Set the TV SYSTEM switch to 1.
2. Input a color bar signal of E8ch (196.25 MHz) and 66 dBµV
(75 
Ω 
OPEN).
3. Connect the digital voltmeter to TP42.
4. Adjust VR1 so that reading on the digital voltmeter is
6.0 ± 0.1 V.
AFT Adjustment
Procedure:
1. Input a color bar signal of E8ch (196.25 MHz) and 74 dBµV
(75 
Ω 
OPEN).
2. Connect the oscilloscope to TP102.
3. Adjust T3 untill the waveform on the oscilloscope is 2.5 Vp-p.
• Use the following equipment for the electrical adjustment.
Equipment
1 Monitor TV (XVM-6100MK2, etc.)
2 Spectrum analyzer
3 TV signal generator
4 Digital voltmeter
5 Oscilloscope
6 Audio analyzer
7 DC power supply
8 Frequency counter
Equipment Connections
Connect the test equipment as shown in the figure below (unless
otherwise instructed) and perform the adjustment.
Setup during Adjustment
Use the video signal obtained from the TV signal generator as the
alignment signal, and check that this signal is within video output
signal standards.
Connection points: Refer to page 12.
Adjustment points: Refer to page 12.
  TUNER UNIT SECTION
Color bar signal from TV signal generator
Note:
Small peaks (dips) coming out from the top of the
waveform are unacceptable.
Page of 40
Display

Click on the first or last page to see other XTL-6100MK2 service manuals if exist.